Running command: "" <> buildModelFMU(Buildings.Examples.Tutorial.Boiler.System6,fileNamePrefix="Buildings_5_0_1_Buildings_Examples_Tutorial_Boiler_System6",fmuType="me",version="2.0",platforms={"dynamic"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadModel(Buildings): time 4.675/4.675, allocations: 403.9 MB / 410.9 MB, free: 4.965 MB / 314.7 MB Notification: Performance of FrontEnd - loaded program: time 0.3202/4.996, allocations: 95 MB / 0.4941 GB, free: 7.367 MB / 410.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.582/5.578, allocations: 92.67 MB / 0.5846 GB, free: 3.457 MB / 474.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 6.538/12.12, allocations: 2.496 GB / 3.081 GB, free: 73.32 MB / 0.7761 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002964/12.12, allocations: 86.64 kB / 3.081 GB, free: 73.27 MB / 0.7761 GB [/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2331:7-2332:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$timTab.getTableValueNoDer. [/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2358:7-2359:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$timTab.getTableTimeTmin. [/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2369:7-2370:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$timTab.getTableTimeTmax. [/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 5.0.1/Fluid/Interfaces/LumpedVolumeDeclarations.mo:3:15-5:45:writable] Notification: From here: [/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 5.0.1/Examples/Tutorial/Boiler/System6.mo:149:3-156:72:writable] Error: component boi contains the definition of a partial class Medium. Please redeclare it to any package compatible with Modelica.Media.Interfaces.PartialMedium. Error: Error occurred while flattening model Buildings.Examples.Tutorial.Boiler.System6 Error: Internal error SimCode: The model Buildings.Examples.Tutorial.Boiler.System6 could not be translated to FMU