OMSimulator --tempDir temp_Buildings_3_0_0_Buildings_Fluid_Movers_Validation_Pump_Nrpm_stratos_fmu --startTime 0 --stopTime 1000 --timeout 50 --tolerance 1e-06 Buildings_3_0_0_Buildings_Fluid_Movers_Validation_Pump_Nrpm_stratos.fmu info: New temp directory has been created: "temp_Buildings_3_0_0_Buildings_Fluid_Movers_Validation_Pump_Nrpm_stratos_fmu" info: New temp directory: "/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelicaLibraryTesting/Buildings_3.0.0_Buildings.Fluid.Movers.Validation.Pump_Nrpm_stratos/temp_Buildings_3_0_0_Buildings_Fluid_Movers_Validation_Pump_Nrpm_stratos_fmu" info: Using "/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelicaLibraryTesting/Buildings_3.0.0_Buildings.Fluid.Movers.Validation.Pump_Nrpm_stratos/temp_Buildings_3_0_0_Buildings_Fluid_Movers_Validation_Pump_Nrpm_stratos_fmu/temp_VIiqRg" as temp directory for fmu assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | forcedPump1.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | forcedPump2.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | forcedPump3.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | forcedPump4.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | forcedPump5.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. stdout | info | The initialization finished successfully without homotopy method. info: Simulation finished. info: time measurement for composite model info: total: 7.823688s info: idle: 0.001587s [0.020285%] info: instantiation: 0.188268s [2.406384%] info: initialization: 0.001270s [0.016233%] info: simulation: 7.626196s [97.475717%] info: communication: 0.006367s [0.081381%] info: result file: 0.000000s [0.000000%] info: time measurement for FMU instance 'fmu' info: initialization: 0.001212s info: do-step: 7.415606s info: result file: 0.000000s info: instantiation: 0.185241s info: events: 0.058853s