Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr BuildingSystems_BuildingSystems.Fluid.HeatPumps.Validation.Carnot_y_etaPL.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.1-master/package.mo", uses=false) Using package NcDataReader2 with version 2.5.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.1-master/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package BuildingSystems with version 2.0.0-beta (/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/package.mo) Running command: "" <> buildModelFMU(BuildingSystems.Fluid.HeatPumps.Validation.Carnot_y_etaPL,fileNamePrefix="BuildingSystems_BuildingSystems_Fluid_HeatPumps_Validation_Carnot_y_etaPL",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(BuildingSystems.Fluid.HeatPumps.Validation.Carnot_y_etaPL,fileNamePrefix="BuildingSystems_BuildingSystems_Fluid_HeatPumps_Validation_Carnot_y_etaPL",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/package.mo): time 0.7077/0.7077, allocations: 141.8 MB / 149.1 MB, free: 1.57 MB / 122.9 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001012/0.001013, allocations: 190.2 kB / 182 MB, free: 13.62 MB / 154.9 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.271/1.271, allocations: 221.3 MB / 436 MB, free: 6.547 MB / 330.9 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0008702/0.0008703, allocations: 97.45 kB / 0.507 GB, free: 18.91 MB / 378.9 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.1-master/package.mo): time 0.001824/0.001824, allocations: 285.9 kB / 0.5885 GB, free: 7.586 MB / 442.9 MB Notification: Performance of FrontEnd - loaded program: time 0.4038/0.4056, allocations: 89.63 MB / 0.676 GB, free: 140.3 MB / 0.5107 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1456/0.5513, allocations: 82.77 MB / 0.7568 GB, free: 90.13 MB / 0.5107 GB Notification: Performance of FrontEnd - scodeFlatten: time 0.9608/1.512, allocations: 389.2 MB / 1.137 GB, free: 265 MB / 0.6982 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002978/1.512, allocations: 93.12 kB / 1.137 GB, free: 265 MB / 0.6982 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/HeatPumps/Examples/Carnot_y.mo:20:3-34:67:writable] Error: Variable heaPum: Cyclically dependent constants or parameters found in scope BuildingSystems.Fluid.HeatPumps.Carnot_y$heaPum: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model BuildingSystems.Fluid.HeatPumps.Validation.Carnot_y_etaPL Error: Internal error SimCode: The model BuildingSystems.Fluid.HeatPumps.Validation.Carnot_y_etaPL could not be translated to FMU