Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr BuildingSystems_BuildingSystems.Fluid.HeatPumps.Validation.Carnot_TCon_etaPL.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.1-master/package.mo", uses=false) Using package NcDataReader2 with version 2.5.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.1-master/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package BuildingSystems with version 2.0.0-beta (/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/package.mo) Running command: "" <> buildModelFMU(BuildingSystems.Fluid.HeatPumps.Validation.Carnot_TCon_etaPL,fileNamePrefix="BuildingSystems_BuildingSystems_Fluid_HeatPumps_Validation_Carnot_TCon_etaPL",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(BuildingSystems.Fluid.HeatPumps.Validation.Carnot_TCon_etaPL,fileNamePrefix="BuildingSystems_BuildingSystems_Fluid_HeatPumps_Validation_Carnot_TCon_etaPL",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/package.mo): time 0.7134/0.7134, allocations: 141.8 MB / 149.1 MB, free: 13.86 MB / 138.9 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001039/0.001039, allocations: 173.8 kB / 181.9 MB, free: 10.46 MB / 154.9 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.255/1.255, allocations: 221.3 MB / 436 MB, free: 2.988 MB / 330.9 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.000873/0.0008731, allocations: 91.23 kB / 0.507 GB, free: 18 MB / 378.9 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.1-master/package.mo): time 0.001759/0.001759, allocations: 269.1 kB / 0.5884 GB, free: 4.449 MB / 442.9 MB Notification: Performance of FrontEnd - loaded program: time 0.3572/0.359, allocations: 89.64 MB / 0.676 GB, free: 137.2 MB / 0.5107 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1319/0.4909, allocations: 82.78 MB / 0.7568 GB, free: 84.3 MB / 0.5107 GB Notification: Performance of FrontEnd - scodeFlatten: time 0.5977/1.089, allocations: 393.6 MB / 1.141 GB, free: 184 kB / 0.6982 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002511/1.089, allocations: 91.06 kB / 1.141 GB, free: 140 kB / 0.6982 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/HeatPumps/Examples/Carnot_TCon.mo:17:3-31:71:writable] Error: Variable heaPum: Cyclically dependent constants or parameters found in scope BuildingSystems.Fluid.HeatPumps.Carnot_TCon$heaPum: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model BuildingSystems.Fluid.HeatPumps.Validation.Carnot_TCon_etaPL Error: Internal error SimCode: The model BuildingSystems.Fluid.HeatPumps.Validation.Carnot_TCon_etaPL could not be translated to FMU