Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr BuildingSystems_BuildingSystems.Fluid.HeatPumps.Validation.Carnot_TCon_LowTemperature.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.1-master/package.mo", uses=false) Using package NcDataReader2 with version 2.5.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.1-master/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package BuildingSystems with version 2.0.0-beta (/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/package.mo) Running command: "" <> buildModelFMU(BuildingSystems.Fluid.HeatPumps.Validation.Carnot_TCon_LowTemperature,fileNamePrefix="BuildingSystems_BuildingSystems_Fluid_HeatPumps_Validation_Carnot_TCon_LowTemperature",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(BuildingSystems.Fluid.HeatPumps.Validation.Carnot_TCon_LowTemperature,fileNamePrefix="BuildingSystems_BuildingSystems_Fluid_HeatPumps_Validation_Carnot_TCon_LowTemperature",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/package.mo): time 0.7037/0.7037, allocations: 141.8 MB / 149.1 MB, free: 13.71 MB / 138.9 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001078/0.001078, allocations: 182.2 kB / 182 MB, free: 10.32 MB / 154.9 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.253/1.253, allocations: 221.3 MB / 436 MB, free: 2.844 MB / 330.9 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0008683/0.0008682, allocations: 98.03 kB / 0.507 GB, free: 17.78 MB / 378.9 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.1-master/package.mo): time 0.001836/0.001836, allocations: 262 kB / 0.5885 GB, free: 4.312 MB / 442.9 MB Notification: Performance of FrontEnd - loaded program: time 0.3686/0.3705, allocations: 89.64 MB / 0.676 GB, free: 137 MB / 0.5107 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1412/0.5117, allocations: 82.77 MB / 0.7568 GB, free: 84.09 MB / 0.5107 GB Notification: Performance of FrontEnd - scodeFlatten: time 0.6125/1.124, allocations: 393.7 MB / 1.141 GB, free: 15.84 MB / 0.7138 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002595/1.125, allocations: 86.94 kB / 1.141 GB, free: 15.8 MB / 0.7138 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/HeatPumps/Examples/Carnot_TCon.mo:17:3-31:71:writable] Error: Variable heaPum: Cyclically dependent constants or parameters found in scope BuildingSystems.Fluid.HeatPumps.Carnot_TCon$heaPum: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model BuildingSystems.Fluid.HeatPumps.Validation.Carnot_TCon_LowTemperature Error: Internal error SimCode: The model BuildingSystems.Fluid.HeatPumps.Validation.Carnot_TCon_LowTemperature could not be translated to FMU