Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr BuildingSystems_BuildingSystems.Fluid.Chillers.Validation.Carnot_y_etaPL.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.1-master/package.mo", uses=false) Using package NcDataReader2 with version 2.5.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.1-master/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package BuildingSystems with version 2.0.0-beta (/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/package.mo) Running command: "" <> buildModelFMU(BuildingSystems.Fluid.Chillers.Validation.Carnot_y_etaPL,fileNamePrefix="BuildingSystems_BuildingSystems_Fluid_Chillers_Validation_Carnot_y_etaPL",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(BuildingSystems.Fluid.Chillers.Validation.Carnot_y_etaPL,fileNamePrefix="BuildingSystems_BuildingSystems_Fluid_Chillers_Validation_Carnot_y_etaPL",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/package.mo): time 0.746/0.746, allocations: 141.8 MB / 149.1 MB, free: 9.41 MB / 138.9 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001372/0.001372, allocations: 190.1 kB / 181.9 MB, free: 6.449 MB / 154.9 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.378/1.378, allocations: 221.4 MB / 436 MB, free: 14.38 MB / 346.9 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001013/0.001013, allocations: 92.98 kB / 0.507 GB, free: 7.652 MB / 394.9 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.1-master/package.mo): time 0.001999/0.001999, allocations: 277.6 kB / 0.5884 GB, free: 4.453 MB / 474.9 MB Notification: Performance of FrontEnd - loaded program: time 0.4597/0.4617, allocations: 89.63 MB / 0.676 GB, free: 165.8 MB / 0.5419 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1642/0.6259, allocations: 82.78 MB / 0.7568 GB, free: 112.8 MB / 0.5419 GB Notification: Performance of FrontEnd - scodeFlatten: time 0.6965/1.322, allocations: 383.5 MB / 1.131 GB, free: 3.082 MB / 0.6982 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002258/1.323, allocations: 92.62 kB / 1.131 GB, free: 3.039 MB / 0.6982 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Chillers/Examples/Carnot_y.mo:22:3-36:67:writable] Error: Variable chi: Cyclically dependent constants or parameters found in scope BuildingSystems.Fluid.Chillers.Carnot_y$chi: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model BuildingSystems.Fluid.Chillers.Validation.Carnot_y_etaPL Error: Internal error SimCode: The model BuildingSystems.Fluid.Chillers.Validation.Carnot_y_etaPL could not be translated to FMU