Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr BuildingSystems_BuildingSystems.Fluid.Chillers.Validation.Carnot_TEva_LimitedCapacity.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.1-master/package.mo", uses=false) Using package NcDataReader2 with version 2.5.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.1-master/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package BuildingSystems with version 2.0.0-beta (/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/package.mo) Running command: "" <> buildModelFMU(BuildingSystems.Fluid.Chillers.Validation.Carnot_TEva_LimitedCapacity,fileNamePrefix="BuildingSystems_BuildingSystems_Fluid_Chillers_Validation_Carnot_TEva_LimitedCapacity",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(BuildingSystems.Fluid.Chillers.Validation.Carnot_TEva_LimitedCapacity,fileNamePrefix="BuildingSystems_BuildingSystems_Fluid_Chillers_Validation_Carnot_TEva_LimitedCapacity",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/package.mo): time 0.7423/0.7423, allocations: 141.8 MB / 149.1 MB, free: 1.57 MB / 122.9 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001177/0.001176, allocations: 177.3 kB / 181.9 MB, free: 0.9844 MB / 154.9 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.388/1.388, allocations: 221.4 MB / 436 MB, free: 5.719 MB / 330.9 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001041/0.001041, allocations: 100 kB / 0.507 GB, free: 2.406 MB / 410.9 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.1-master/package.mo): time 0.001723/0.001724, allocations: 288.6 kB / 0.5885 GB, free: 47.45 MB / 410.9 MB Notification: Performance of FrontEnd - loaded program: time 0.3688/0.3706, allocations: 89.62 MB / 0.676 GB, free: 59.8 MB / 442.9 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1624/0.533, allocations: 82.78 MB / 0.7568 GB, free: 0.8281 MB / 442.9 MB Notification: Performance of FrontEnd - scodeFlatten: time 1/1.533, allocations: 393.4 MB / 1.141 GB, free: 199 MB / 0.7138 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002021/1.534, allocations: 93.2 kB / 1.141 GB, free: 199 MB / 0.7138 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Chillers/Examples/Carnot_TEva.mo:18:3-32:70:writable] Error: Variable chi: Cyclically dependent constants or parameters found in scope BuildingSystems.Fluid.Chillers.Carnot_TEva$chi: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model BuildingSystems.Fluid.Chillers.Validation.Carnot_TEva_LimitedCapacity Error: Internal error SimCode: The model BuildingSystems.Fluid.Chillers.Validation.Carnot_TEva_LimitedCapacity could not be translated to FMU