Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr BuildingSystems_BuildingSystems.Fluid.Chillers.Validation.Carnot_TEva_HighTemperature.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.1-master/package.mo", uses=false) Using package NcDataReader2 with version 2.5.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.1-master/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package BuildingSystems with version 2.0.0-beta (/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/package.mo) Running command: "" <> buildModelFMU(BuildingSystems.Fluid.Chillers.Validation.Carnot_TEva_HighTemperature,fileNamePrefix="BuildingSystems_BuildingSystems_Fluid_Chillers_Validation_Carnot_TEva_HighTemperature",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(BuildingSystems.Fluid.Chillers.Validation.Carnot_TEva_HighTemperature,fileNamePrefix="BuildingSystems_BuildingSystems_Fluid_Chillers_Validation_Carnot_TEva_HighTemperature",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/package.mo): time 0.7432/0.7432, allocations: 141.8 MB / 149.1 MB, free: 11.89 MB / 138.9 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001238/0.001238, allocations: 185.4 kB / 182 MB, free: 8.668 MB / 154.9 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.374/1.374, allocations: 221.4 MB / 436.1 MB, free: 1.008 MB / 330.9 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0009384/0.0009384, allocations: 91.64 kB / 0.5071 GB, free: 9.961 MB / 394.9 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.1-master/package.mo): time 0.001816/0.001816, allocations: 277.7 kB / 0.5885 GB, free: 6.781 MB / 474.9 MB Notification: Performance of FrontEnd - loaded program: time 0.2135/0.2153, allocations: 89.63 MB / 0.676 GB, free: 13.06 MB / 0.5575 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.4455/0.6608, allocations: 82.78 MB / 0.7569 GB, free: 137.9 MB / 0.5575 GB Notification: Performance of FrontEnd - scodeFlatten: time 0.664/1.325, allocations: 393.5 MB / 1.141 GB, free: 6.34 MB / 0.6825 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002718/1.325, allocations: 88 kB / 1.141 GB, free: 6.301 MB / 0.6825 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Chillers/Examples/Carnot_TEva.mo:18:3-32:70:writable] Error: Variable chi: Cyclically dependent constants or parameters found in scope BuildingSystems.Fluid.Chillers.Carnot_TEva$chi: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model BuildingSystems.Fluid.Chillers.Validation.Carnot_TEva_HighTemperature Error: Internal error SimCode: The model BuildingSystems.Fluid.Chillers.Validation.Carnot_TEva_HighTemperature could not be translated to FMU