Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr BuildingSystems_BuildingSystems.Fluid.Chillers.Validation.CarnotVerifyEtaCarnot.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.1-master/package.mo", uses=false) Using package NcDataReader2 with version 2.5.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.1-master/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package BuildingSystems with version 2.0.0-beta (/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/package.mo) Running command: "" <> buildModelFMU(BuildingSystems.Fluid.Chillers.Validation.CarnotVerifyEtaCarnot,fileNamePrefix="BuildingSystems_BuildingSystems_Fluid_Chillers_Validation_CarnotVerifyEtaCarnot",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(BuildingSystems.Fluid.Chillers.Validation.CarnotVerifyEtaCarnot,fileNamePrefix="BuildingSystems_BuildingSystems_Fluid_Chillers_Validation_CarnotVerifyEtaCarnot",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/package.mo): time 0.7238/0.7238, allocations: 141.8 MB / 149.1 MB, free: 6.941 MB / 138.9 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001108/0.001108, allocations: 181.7 kB / 182 MB, free: 4.363 MB / 154.9 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.421/1.421, allocations: 221.3 MB / 436 MB, free: 12.08 MB / 347 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0009582/0.0009582, allocations: 94.42 kB / 0.507 GB, free: 5.602 MB / 395 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.1-master/package.mo): time 0.001809/0.001809, allocations: 282.2 kB / 0.5885 GB, free: 2.41 MB / 475 MB Notification: Performance of FrontEnd - loaded program: time 0.3987/0.4005, allocations: 89.62 MB / 0.676 GB, free: 164.6 MB / 0.542 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1604/0.5609, allocations: 82.79 MB / 0.7568 GB, free: 109.6 MB / 0.542 GB Notification: Performance of FrontEnd - scodeFlatten: time 0.6528/1.214, allocations: 396.2 MB / 1.144 GB, free: 3.227 MB / 0.7139 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002091/1.214, allocations: 90.62 kB / 1.144 GB, free: 3.184 MB / 0.7139 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Chillers/Validation/CarnotVerifyEtaCarnot.mo:52:3-70:69:writable] Error: Variable chi_TEva: Cyclically dependent constants or parameters found in scope BuildingSystems.Fluid.Chillers.Carnot_TEva$chi_TEva: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model BuildingSystems.Fluid.Chillers.Validation.CarnotVerifyEtaCarnot Error: Internal error SimCode: The model BuildingSystems.Fluid.Chillers.Validation.CarnotVerifyEtaCarnot could not be translated to FMU