Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr BuildingSystems_BuildingSystems.Fluid.Chillers.Validation.CarnotVerifyCOP.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.1-master/package.mo", uses=false) Using package NcDataReader2 with version 2.5.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.1-master/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package BuildingSystems with version 2.0.0-beta (/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/package.mo) Running command: "" <> buildModelFMU(BuildingSystems.Fluid.Chillers.Validation.CarnotVerifyCOP,fileNamePrefix="BuildingSystems_BuildingSystems_Fluid_Chillers_Validation_CarnotVerifyCOP",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(BuildingSystems.Fluid.Chillers.Validation.CarnotVerifyCOP,fileNamePrefix="BuildingSystems_BuildingSystems_Fluid_Chillers_Validation_CarnotVerifyCOP",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/package.mo): time 0.7767/0.7767, allocations: 141.8 MB / 149.1 MB, free: 0.9297 MB / 122.9 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001222/0.001222, allocations: 191 kB / 182 MB, free: 13.09 MB / 154.9 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.32/1.32, allocations: 221.3 MB / 436 MB, free: 5.863 MB / 330.9 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001143/0.001143, allocations: 92.55 kB / 0.507 GB, free: 18.91 MB / 378.9 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.1-master/package.mo): time 0.002093/0.002093, allocations: 278.5 kB / 0.5885 GB, free: 7.02 MB / 442.9 MB Notification: Performance of FrontEnd - loaded program: time 0.4139/0.416, allocations: 89.63 MB / 0.676 GB, free: 139.7 MB / 0.5107 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1613/0.5773, allocations: 82.77 MB / 0.7568 GB, free: 89.05 MB / 0.5107 GB Notification: Performance of FrontEnd - scodeFlatten: time 0.955/1.532, allocations: 396 MB / 1.144 GB, free: 215.8 MB / 0.6982 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002104/1.533, allocations: 92.78 kB / 1.144 GB, free: 215.8 MB / 0.6982 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Chillers/Validation/CarnotVerifyCOP.mo:41:3-58:69:writable] Error: Variable chi_TEva: Cyclically dependent constants or parameters found in scope BuildingSystems.Fluid.Chillers.Carnot_TEva$chi_TEva: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model BuildingSystems.Fluid.Chillers.Validation.CarnotVerifyCOP Error: Internal error SimCode: The model BuildingSystems.Fluid.Chillers.Validation.CarnotVerifyCOP could not be translated to FMU