Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr BuildSysPro_BuildSysPro.Systems.HVAC.Emission.Examples.RadiatorEN442_Test.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.5.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package BuildSysPro with version 3.4.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.5.0/package.mo) Running command: "" <> buildModelFMU(BuildSysPro.Systems.HVAC.Emission.Examples.RadiatorEN442_Test,fileNamePrefix="BuildSysPro_BuildSysPro_Systems_HVAC_Emission_Examples_RadiatorEN442_Test",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(BuildSysPro.Systems.HVAC.Emission.Examples.RadiatorEN442_Test,fileNamePrefix="BuildSysPro_BuildSysPro_Systems_HVAC_Emission_Examples_RadiatorEN442_Test",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.5.0/package.mo): time 0.6802/0.6802, allocations: 127.4 MB / 134.6 MB, free: 4.078 MB / 106.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001145/0.001145, allocations: 181.3 kB / 164.4 MB, free: 6.875 MB / 138.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.536/1.536, allocations: 205.1 MB / 399.1 MB, free: 6.172 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.00089/0.00089, allocations: 88.02 kB / 476.3 MB, free: 8.922 MB / 378.7 MB Notification: Performance of FrontEnd - loaded program: time 0.3186/0.3195, allocations: 82.88 MB / 0.5461 GB, free: 42.69 MB / 378.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1676/0.4872, allocations: 76.75 MB / 0.621 GB, free: 13.87 MB / 426.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo:2:1-8495:13:writable] Error: Class Units.SI.EnergyFlowRate not found in scope Modelica. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.5.0/Systems/HVAC/Emission/Examples/RadiatorEN442_Test.mo:4:3-4:54:writable] Error: Class Modelica.Units.SI.EnergyFlowRate not found in scope BuildSysPro.Systems.HVAC.Emission.Examples.RadiatorEN442_Test. Error: Error occurred while flattening model BuildSysPro.Systems.HVAC.Emission.Examples.RadiatorEN442_Test Error: Internal error SimCode: The model BuildSysPro.Systems.HVAC.Emission.Examples.RadiatorEN442_Test could not be translated to FMU