Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr BuildSysPro_BuildSysPro.IBPSA.Fluid.HeatPumps.Validation.Carnot_y_etaCar.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.5.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package BuildSysPro with version 3.4.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.5.0/package.mo) Running command: "" <> buildModelFMU(BuildSysPro.IBPSA.Fluid.HeatPumps.Validation.Carnot_y_etaCar,fileNamePrefix="BuildSysPro_BuildSysPro_IBPSA_Fluid_HeatPumps_Validation_Carnot_y_etaCar",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(BuildSysPro.IBPSA.Fluid.HeatPumps.Validation.Carnot_y_etaCar,fileNamePrefix="BuildSysPro_BuildSysPro_IBPSA_Fluid_HeatPumps_Validation_Carnot_y_etaCar",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.5.0/package.mo): time 0.828/0.828, allocations: 127.4 MB / 134.6 MB, free: 4.086 MB / 106.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.0014/0.0014, allocations: 181.3 kB / 164.4 MB, free: 6.891 MB / 138.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.921/1.921, allocations: 205.1 MB / 399.1 MB, free: 6.16 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001353/0.001353, allocations: 88.17 kB / 476.3 MB, free: 8.914 MB / 378.7 MB Notification: Performance of FrontEnd - loaded program: time 0.3553/0.3567, allocations: 82.9 MB / 0.5461 GB, free: 42.68 MB / 378.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2307/0.5874, allocations: 76.74 MB / 0.621 GB, free: 13.86 MB / 426.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 1.051/1.638, allocations: 379.4 MB / 0.9916 GB, free: 103.1 MB / 0.6198 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.000277/1.638, allocations: 88.2 kB / 0.9916 GB, free: 103.1 MB / 0.6198 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.5.0/IBPSA/Fluid/HeatPumps/Examples/Carnot_y.mo:20:3-34:67:writable] Error: Variable heaPum: Cyclically dependent constants or parameters found in scope BuildSysPro.IBPSA.Fluid.HeatPumps.Carnot_y$heaPum: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model BuildSysPro.IBPSA.Fluid.HeatPumps.Validation.Carnot_y_etaCar Error: Internal error SimCode: The model BuildSysPro.IBPSA.Fluid.HeatPumps.Validation.Carnot_y_etaCar could not be translated to FMU