Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr AixLib_latest_AixLib.Obsolete.YearIndependent.FastHVAC.Components.Pipes.DynamicPipeAggregated.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_DeviceDrivers 2.1.1/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/SDF master/package.mo", uses=false) Using package SDF with version 0.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/SDF master/package.mo) Using package Modelica_DeviceDrivers with version 2.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_DeviceDrivers 2.1.1/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package AixLib with version 1.3.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/package.mo) Running command: "" <> buildModelFMU(AixLib.Obsolete.YearIndependent.FastHVAC.Components.Pipes.DynamicPipeAggregated,fileNamePrefix="AixLib_latest_AixLib_Obsolete_YearIndependent_FastHVAC_Components_Pipes_DynamicPipeAggregated",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(AixLib.Obsolete.YearIndependent.FastHVAC.Components.Pipes.DynamicPipeAggregated,fileNamePrefix="AixLib_latest_AixLib_Obsolete_YearIndependent_FastHVAC_Components_Pipes_DynamicPipeAggregated",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/BoundaryConditions/InternalGains/Examples/InternalGains/Lights.mo:27:20-27:398:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/BoundaryConditions/InternalGains/Examples/InternalGains/Machines.mo:31:20-31:400:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/DataBase/CHP/CHPDataSimple/CHP_Cleanergy_C9G.mo:36:34-36:594:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/DataBase/CHP/CHPDataSimple/CHP_XRGI_9kWel.mo:25:34-25:588:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/DataBase/CHP/CHPDataSimple/CHP_XRGI_9kWel.mo:25:34-25:3852:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/DataBase/Weather/SurfaceOrientation/SurfaceOrientationData_NE_SE_SW_NW_Hor.mo:5:35-5:324:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/DataBase/Weather/SurfaceOrientation/SurfaceOrientationData_N_E_S_W_Hor.mo:5:35-5:320:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/DataBase/Weather/SurfaceOrientation/SurfaceOrientationData_N_E_S_W_RoofN_Roof_S.mo:5:35-5:362:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/Obsolete/YearIndependent/FastHVAC/Components/HeatExchangers/RadiatorMultiLayer.mo:265:34-265:6228:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/Obsolete/YearIndependent/FastHVAC/Components/HeatExchangers/RadiatorMultiLayer.mo:265:34-265:6853:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/Obsolete/YearIndependent/FastHVAC/Components/HeatExchangers/RadiatorMultiLayer.mo:265:34-265:8435:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/Obsolete/YearIndependent/FastHVAC/Components/HeatExchangers/RadiatorMultiLayer.mo:265:34-265:9369:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/Obsolete/YearIndependent/FastHVAC/Components/HeatExchangers/RadiatorMultiLayer.mo:265:34-265:11505:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/Obsolete/YearIndependent/FastHVAC/Components/HeatExchangers/RadiatorMultiLayer.mo:265:34-265:12875:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/ThermalZones/HighOrder/Components/DryAir/InfiltrationRate_DIN12831.mo:20:192-20:2066:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/ThermalZones/HighOrder/Components/DryAir/InfiltrationRate_DIN12831.mo:20:192-20:4252:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/ThermalZones/HighOrder/Components/Examples/DryAir/DryAir_test.mo:71:18-71:405:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/package.mo): time 1.487/1.487, allocations: 265 MB / 272.3 MB, free: 8.844 MB / 218.8 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001043/0.001043, allocations: 181.3 kB / 329.7 MB, free: 396 kB / 266.8 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.193/1.193, allocations: 221.4 MB / 0.5941 GB, free: 14.61 MB / 458.8 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0008996/0.0008996, allocations: 92.62 kB / 0.6993 GB, free: 2.75 MB / 0.5418 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_DeviceDrivers 2.1.1/package.mo): time 0.04838/0.04838, allocations: 11.89 MB / 0.816 GB, free: 65.64 MB / 0.5418 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/SDF master/package.mo:9:42-9:258:writable] Notification: This is an open source dummy package of a commercial library. If you want it to be supported, you will need to add an implemention on our github repository: https://github.com/Modelica-OpenVendorSpecificLibraries. Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/SDF master/package.mo): time 0.0003745/0.0003745, allocations: 13.97 kB / 0.924 GB, free: 87.03 MB / 0.573 GB Warning: Ignoring unknown experiment annotation option: Algorithm = "Lsodar" Notification: Performance of FrontEnd - loaded program: time 0.1777/0.1781, allocations: 117.8 MB / 1.039 GB, free: 9.227 MB / 0.5887 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.186/0.3641, allocations: 110.2 MB / 1.147 GB, free: 10.9 MB / 0.698 GB Notification: Performance of FrontEnd - scodeFlatten: time 0.4982/0.8623, allocations: 144.2 MB / 1.288 GB, free: 46.01 MB / 0.7293 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002188/0.8626, allocations: 91.17 kB / 1.288 GB, free: 45.96 MB / 0.7293 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/Obsolete/YearIndependent/FastHVAC/Interfaces/EnthalpyPort_a.mo:2:1-20:19:writable] Warning: Connector .AixLib.Obsolete.YearIndependent.FastHVAC.Interfaces.EnthalpyPort_a is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/Obsolete/YearIndependent/FastHVAC/Interfaces/EnthalpyPort_b.mo:2:1-24:19:writable] Warning: Connector .AixLib.Obsolete.YearIndependent.FastHVAC.Interfaces.EnthalpyPort_b is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/Obsolete/YearIndependent/FastHVAC/Interfaces/EnthalpyPort_a.mo:2:1-20:19:writable] Warning: Connector .AixLib.Obsolete.YearIndependent.FastHVAC.Interfaces.EnthalpyPort_a is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/Obsolete/YearIndependent/FastHVAC/Interfaces/EnthalpyPort_b.mo:2:1-24:19:writable] Warning: Connector .AixLib.Obsolete.YearIndependent.FastHVAC.Interfaces.EnthalpyPort_b is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/Obsolete/YearIndependent/FastHVAC/Interfaces/EnthalpyPort_a.mo:2:1-20:19:writable] Warning: Connector .AixLib.Obsolete.YearIndependent.FastHVAC.Interfaces.EnthalpyPort_a is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/Obsolete/YearIndependent/FastHVAC/Interfaces/EnthalpyPort_b.mo:2:1-24:19:writable] Warning: Connector .AixLib.Obsolete.YearIndependent.FastHVAC.Interfaces.EnthalpyPort_b is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/Obsolete/YearIndependent/FastHVAC/Interfaces/EnthalpyPort_a.mo:2:1-20:19:writable] Warning: Connector .AixLib.Obsolete.YearIndependent.FastHVAC.Interfaces.EnthalpyPort_a is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/Obsolete/YearIndependent/FastHVAC/Interfaces/EnthalpyPort_b.mo:2:1-24:19:writable] Warning: Connector .AixLib.Obsolete.YearIndependent.FastHVAC.Interfaces.EnthalpyPort_b is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/Obsolete/YearIndependent/FastHVAC/Interfaces/EnthalpyPort_a.mo:2:1-20:19:writable] Warning: Connector .AixLib.Obsolete.YearIndependent.FastHVAC.Interfaces.EnthalpyPort_a is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/Obsolete/YearIndependent/FastHVAC/Interfaces/EnthalpyPort_b.mo:2:1-24:19:writable] Warning: Connector .AixLib.Obsolete.YearIndependent.FastHVAC.Interfaces.EnthalpyPort_b is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/Obsolete/YearIndependent/FastHVAC/Interfaces/EnthalpyPort_a.mo:2:1-20:19:writable] Warning: Connector .AixLib.Obsolete.YearIndependent.FastHVAC.Interfaces.EnthalpyPort_a is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/Obsolete/YearIndependent/FastHVAC/Interfaces/EnthalpyPort_b.mo:2:1-24:19:writable] Warning: Connector .AixLib.Obsolete.YearIndependent.FastHVAC.Interfaces.EnthalpyPort_b is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/Obsolete/YearIndependent/FastHVAC/Interfaces/EnthalpyPort_a.mo:2:1-20:19:writable] Warning: Connector .AixLib.Obsolete.YearIndependent.FastHVAC.Interfaces.EnthalpyPort_a is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). Error: Too few equations, under-determined system. The model has 278 equation(s) and 282 variable(s). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/Obsolete/YearIndependent/FastHVAC/Interfaces/EnthalpyPort.mo:4:3-4:53:writable] Warning: Variable pipeBase.enthalpyPort_a1.T does not have any remaining equation to be solved in. The original equations were: Equation 271: enthalpyPort_a1.T = pipeBase.enthalpyPort_a1.T, which needs to solve for enthalpyPort_a1.T Equation 182: pipeBase.enthalpyPort_a1.T = pipeBase.pipeFluid[1].enthalpyPort_a.T, which needs to solve for pipeBase.pipeFluid[1].enthalpyPort_a.T Error: Internal error SimCode: The model AixLib.Obsolete.YearIndependent.FastHVAC.Components.Pipes.DynamicPipeAggregated could not be translated to FMU