startTime=0 stopTime=4e+06 tolerance=1e-06 numberOfIntervals=4444 stepSize=900.09 wasm-jit simulation: simulate(TransiEnt.Storage.Electrical.Controller.Check.TestLoadSmoothingController,startTime=0,stopTime=4e+06,tolerance=1e-06,numberOfIntervals=4444,outputFormat="empty",variableFilter="",fileNamePrefix="TransiEnt_TransiEnt.Storage.Electrical.Controller.Check.TestLoadSmoothingController",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS") LOG_STDOUT | warning | The nominal value of simCenter.rh_amb is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables//ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/electricity/REProfiles/Wind2012_TenneT_900s.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/electricity/REProfiles/Wind2012_TenneT_900s.txt LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/electricity/ElectricityDemandHH_900s_01.01.20120-01.01.20130.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/electricity/ElectricityDemandHH_900s_01.01.20120-01.01.20130.txt LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 6.8309e-05s [ 0.1%] pre-initialization | | | | | | 0.0817058s [ 65.0%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0.00750025s [ 6.0%] solver (excl. callbacks) | | | | | | 4.268e-06s [ 0.0%] creating output-file | | | | | | 0.00718113s [ 5.7%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 0.0293013s [ 23.3%] simulation | | | | | | 0.125761s [100.0%] total | | | | | events | | | | | | 48 state events | | | | | | 1 time events | | | | | solver: dassl | | | | | | 16412 steps taken | | | | | | 34092 calls of functionODE | | | | | | 19525 evaluations of jacobian | | | | | | 1998 error test failures | | | | | | 4489 convergence test failures | | | | | | 0.00674225s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.