Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/./OMCompiler/build TransiEnt_TransiEnt.Producer.Gas.Electrolyzer.Systems.Check.TestElectrolyzerAndCavern.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/DymolaCommands master/package.mo", uses=false) [Timeout 180] "[:1:22-1:33:writable] Warning: Modelica only supports 32-bit signed integers! Transforming: 13743895347 into a real Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/DymolaCommands master/package.mo): time 0.0002322/0.0002322, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFInstanceAPI.mkTop(): time 0.0005035/0.0007357, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/package.mo", uses=false) [Timeout 180] "[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Control/PredictorModels_3508/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestReheater, which is expected to be stored in file TestReheater.mo, but seems to be named testReheater.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Control/PredictorModels_3508/Check/testReheater.mo:2:1-117:17:writable] Warning: Expected the package to have name testReheater, but got TestReheater. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/package.mo:2:1-23:10:writable] Warning: PhysicalMills was referenced in the package.order file, but was not found in package.mo, PhysicalMills/package.mo or PhysicalMills.mo. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/package.mo:2:1-22:18:writable] Warning: Expected the package to have name physicalMills, but got PhysicalMills. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/package.mo:2:1-22:18:writable] Warning: The package.order file contains a class Mill_L4_advancedInit, which is expected to be stored in file Mill_L4_advancedInit.mo, but seems to be named mill_L4_advancedInit.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/package.mo:2:1-22:18:writable] Warning: The package.order file contains a class Mill_L4, which is expected to be stored in file Mill_L4.mo, but seems to be named mill_L4.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/mill_L4_advancedInit.mo:2:1-58:25:writable] Warning: Expected the package to have name mill_L4_advancedInit, but got Mill_L4_advancedInit. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/mill_L4_advancedInit.mo:2:1-58:25:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/mill_L4.mo:2:1-315:12:writable] Warning: Expected the package to have name mill_L4, but got Mill_L4. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/mill_L4.mo:2:1-315:12:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestMillBox_2, which is expected to be stored in file TestMillBox_2.mo, but seems to be named testMillBox_2.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestMillBox_1_measurementInput, which is expected to be stored in file TestMillBox_1_measurementInput.mo, but seems to be named testMillBox_1_measurementInput.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestMillBox_1, which is expected to be stored in file TestMillBox_1.mo, but seems to be named testMillBox_1.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Check/testMillBox_2.mo:2:1-297:18:writable] Warning: Expected the package to have name testMillBox_2, but got TestMillBox_2. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Check/testMillBox_2.mo:2:1-297:18:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Check; but got within ClaRa.Components.Mills.PhysicalMills.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Check/testMillBox_1_measurementInput.mo:2:1-1342:35:writable] Warning: Expected the package to have name testMillBox_1_measurementInput, but got TestMillBox_1_measurementInput. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Check/testMillBox_1_measurementInput.mo:2:1-1342:35:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Check; but got within ClaRa.Components.Mills.PhysicalMills.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Check/testMillBox_1.mo:2:1-465:18:writable] Warning: Expected the package to have name testMillBox_1, but got TestMillBox_1. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Check/testMillBox_1.mo:2:1-465:18:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Check; but got within ClaRa.Components.Mills.PhysicalMills.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/package.mo:2:1-29:12:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/FlowClassifier.mo:2:1-346:19:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/CentrifugalClassifier.mo:2:1-380:26:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/GrinderRingRoller.mo:2:1-294:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/FuelJoin_distributed.mo:2:1-133:25:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Dryer.mo:2:1-301:10:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/package.mo:2:1-20:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/package.mo:2:1-20:13:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/package.mo:2:1-20:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/Transport_complex.mo:2:1-71:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/Transport_constant.mo:2:1-49:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/Transport_base.mo:2:1-52:19:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/package.mo:2:1-20:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_Kersting.mo:2:1-80:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_Steinmetz.mo:2:1-104:24:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_constant.mo:2:1-45:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_base.mo:2:1-50:19:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/package.mo:2:1-20:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_Austin.mo:2:1-109:20:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_Steinmetz.mo:2:1-106:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_constant.mo:2:1-45:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_base.mo:2:1-51:18:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Drying/package.mo:2:1-20:11:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Drying/Drying_ideal.mo:2:1-58:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Drying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Drying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Drying/Drying_base.mo:2:1-44:16:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Drying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Drying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/package.mo:2:1-20:16:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_flow.mo:2:1-111:21:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_centrifugal.mo:2:1-153:28:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_centrifugal_base.mo:2:1-45:33:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_flow_base.mo:2:1-45:26:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/package.mo:2:1-20:12:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_Dryer.mo:2:1-57:15:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_FlowClassifier.mo:2:1-67:24:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_CentrifugalClassifier.mo:2:1-69:31:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_Grinder.mo:2:1-61:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_example_21classes.mo:2:1-43:41:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/GeometricProgression.mo:2:1-56:25:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_generic.mo:2:1-43:31:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_example_05classes.mo:2:1-43:41:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_example_11classes.mo:2:1-43:41:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_base.mo:2:1-61:28:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestFuelJoin, which is expected to be stored in file TestFuelJoin.mo, but seems to be named testFuelJoin.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestAerosolVolume, which is expected to be stored in file TestAerosolVolume.mo, but seems to be named testAerosolVolume.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestDryer, which is expected to be stored in file TestDryer.mo, but seems to be named testDryer.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestGrinder, which is expected to be stored in file TestGrinder.mo, but seems to be named testGrinder.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/testFuelJoin.mo:2:1-93:17:writable] Warning: Expected the package to have name testFuelJoin, but got TestFuelJoin. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/testFuelJoin.mo:2:1-93:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/testAerosolVolume.mo:2:1-176:22:writable] Warning: Expected the package to have name testAerosolVolume, but got TestAerosolVolume. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/testAerosolVolume.mo:2:1-176:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/testDryer.mo:2:1-93:14:writable] Warning: Expected the package to have name testDryer, but got TestDryer. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/testDryer.mo:2:1-93:14:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/testGrinder.mo:2:1-154:16:writable] Warning: Expected the package to have name testGrinder, but got TestGrinder. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/testGrinder.mo:2:1-154:16:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/package.mo): time 0.08989/0.08989, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFInstanceAPI.mkTop(): time 0.03688/0.1268, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-ClaRa/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-ClaRa/package.mo): time 0.0206/0.0206, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFInstanceAPI.mkTop(): time 0.01477/0.03538, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.0002895/0.0002895, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFInstanceAPI.mkTop(): time 0.003672/0.003961, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.0002274/0.0002274, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFInstanceAPI.mkTop(): time 0.0005362/0.0007636, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 0.1422/0.1422, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFInstanceAPI.mkTop(): time 0.09249/0.2347, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2/package.mo): time 0.322/0.322, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFInstanceAPI.mkTop(): time 0.1652/0.4873, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/package.mo", uses=false) [Timeout 180] "[/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Consumer/Heat/Check/TestHeatConsumerNode.mo:26:12-26:23:writable] Warning: Modelica only supports 32-bit signed integers! Transforming: 60000000000 into a real [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Consumer/Heat/Check/TestHeatConsumerNode.mo:26:24-26:36:writable] Warning: Modelica only supports 32-bit signed integers! Transforming: 160000000000 into a real [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Producer/Electrical/Wind/Check/TestWindturbine2.mo:39:12-39:25:writable] Warning: Modelica only supports 32-bit signed integers! Transforming: 3500000000000 into a real [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Components/Electrical/PowerTransformation/Check/GridN5AreaFirstVoltageCollapse.mo:225:32-225:42:writable] Warning: Modelica only supports 32-bit signed integers! Transforming: 3000000000 into a real [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Components/Electrical/Machines/ExcitationSystemsVoltageController/Check/GridN5AreaVoltageCollapseOEL.mo:173:32-173:42:writable] Warning: Modelica only supports 32-bit signed integers! Transforming: 3000000000 into a real [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Components/Electrical/Grid/Check/CheckElectricBusbarComplex.mo:179:32-179:42:writable] Warning: Modelica only supports 32-bit signed integers! Transforming: 3000000000 into a real [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Basics/Interfaces/Thermal/package.mo:2:1-91:12:writable] Warning: The package.order file contains a class FluidPortOut_simple, which is expected to be stored in file FluidPortOut_simple.mo, but seems to be named fluidPortOut_simple.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Basics/Interfaces/Thermal/package.mo:2:1-91:12:writable] Warning: The package.order file contains a class FluidPortIn_simple, which is expected to be stored in file FluidPortIn_simple.mo, but seems to be named fluidPortIn_simple.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Basics/Interfaces/Thermal/fluidPortOut_simple.mo:2:1-49:24:writable] Warning: Expected the package to have name fluidPortOut_simple, but got FluidPortOut_simple. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Basics/Interfaces/Thermal/fluidPortIn_simple.mo:2:1-50:23:writable] Warning: Expected the package to have name fluidPortIn_simple, but got FluidPortIn_simple. Proceeding since only the case of the names are different. Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/package.mo): time 0.1822/0.1822, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFInstanceAPI.mkTop(): time 0.07839/0.2605, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 180] Using package TransiEnt with version 2.0.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/package.mo) Using package Buildings with version 12.1.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Using package TILMedia with version 1.8.1 ClaRa (/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-ClaRa/package.mo) Using package ClaRa with version 1.8.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/package.mo) Using package DymolaCommands with version 0.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/DymolaCommands master/package.mo) Running command: simulate(TransiEnt.Producer.Gas.Electrolyzer.Systems.Check.TestElectrolyzerAndCavern,startTime=0,stopTime=604800,tolerance=1e-06,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="TransiEnt_TransiEnt.Producer.Gas.Electrolyzer.Systems.Check.TestElectrolyzerAndCavern",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS") simulate(TransiEnt.Producer.Gas.Electrolyzer.Systems.Check.TestElectrolyzerAndCavern,startTime=0,stopTime=604800,tolerance=1e-06,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="TransiEnt_TransiEnt.Producer.Gas.Electrolyzer.Systems.Check.TestElectrolyzerAndCavern",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS") [Timeout 900] "Notification: Performance of FrontEnd - loaded program: time 1.863e-06/1.863e-06, allocations: 0 / 0, free: 0 / 0 Notification: Performance of FrontEnd - Absyn->SCode: time 4.414e-05/4.601e-05, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFInst.instantiate(TransiEnt.Producer.Gas.Electrolyzer.Systems.Check.TestElectrolyzerAndCavern): time 0.0439/0.04395, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFInst.instExpressions: time 0.05563/0.09958, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFInst.updateImplicitVariability: time 0.009417/0.109, allocations: 0 / 0, free: 0 / 0 [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Components/Statistics/Collectors/LocalCollectors/CollectElectricPower.mo:65:3-65:137:writable] Warning: Connector powerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/SimCenter.mo:69:5-70:35:writable] Warning: Connector cycleSumPort is not balanced: The number of potential variables (0) is not equal to the number of flow variables (4). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/ModelStatistics.mo:83:3-83:105:writable] Warning: Connector powerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/ModelStatistics.mo:84:3-84:112:writable] Warning: Connector primBalPowerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/ModelStatistics.mo:85:3-85:102:writable] Warning: Connector primBalPowerOfferCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/ModelStatistics.mo:86:3-86:111:writable] Warning: Connector secBalPowerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/ModelStatistics.mo:87:3-87:101:writable] Warning: Connector secBalPowerOfferCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/ModelStatistics.mo:88:3-88:92:writable] Warning: Connector surroundingGridLoad is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/ModelStatistics.mo:90:3-90:126:writable] Warning: Connector tielinePowerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/ModelStatistics.mo:91:3-91:130:writable] Warning: Connector tielineSetPowerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/ModelStatistics.mo:93:3-93:95:writable] Warning: Connector kineticEnergyCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/ModelStatistics.mo:96:3-96:99:writable] Warning: Connector gwpCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/ModelStatistics.mo:98:3-98:107:writable] Warning: Connector gwpCollectorHeat is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/ModelStatistics.mo:101:3-101:82:writable] Warning: Connector heatFlowCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/ModelStatistics.mo:103:3-103:87:writable] Warning: Connector costsCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (6). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Components/Statistics/Collectors/LocalCollectors/CollectElectricPower.mo:65:3-65:137:writable] Warning: Connector powerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Components/Statistics/Collectors/LocalCollectors/CollectHeatingPower.mo:66:3-66:143:writable] Warning: Connector heatFlowCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Components/Statistics/Collectors/LocalCollectors/CollectGwpEmissionsElectric.mo:71:3-71:141:writable] Warning: Connector gwpCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Components/Statistics/Collectors/LocalCollectors/PartialCollectCosts.mo:120:3-120:137:writable] Warning: Connector costsCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (6). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] Notification: Performance of NFTyping.typeComponents: time 0.01268/0.1217, allocations: 0 / 0, free: 0 / 0 [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Basics/Functions/fullPathName.mo:2:1-76:17:writable] Warning: Pure function 'TransiEnt.Basics.Functions.fullPathName' contains a call to impure function 'Modelica.Utilities.Streams.print'. Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.BrownCoal as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.BrownCoal) instead! [Non-standard Modelica: --allowNonStandardModelica=nonStdEnumerationAsIntegers] Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.BlackCoal as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.BlackCoal) instead! [Non-standard Modelica: --allowNonStandardModelica=nonStdEnumerationAsIntegers] Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.NaturalGas as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.NaturalGas) instead! [Non-standard Modelica: --allowNonStandardModelica=nonStdEnumerationAsIntegers] Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.WindOnshore as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.WindOnshore) instead! [Non-standard Modelica: --allowNonStandardModelica=nonStdEnumerationAsIntegers] Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.WindOffshore as Integer: 5. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.WindOffshore) instead! [Non-standard Modelica: --allowNonStandardModelica=nonStdEnumerationAsIntegers] Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Solar as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Solar) instead! [Non-standard Modelica: --allowNonStandardModelica=nonStdEnumerationAsIntegers] Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Hydro as Integer: 7. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Hydro) instead! [Non-standard Modelica: --allowNonStandardModelica=nonStdEnumerationAsIntegers] Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Nuclear as Integer: 8. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Nuclear) instead! [Non-standard Modelica: --allowNonStandardModelica=nonStdEnumerationAsIntegers] Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Oil as Integer: 9. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Oil) instead! [Non-standard Modelica: --allowNonStandardModelica=nonStdEnumerationAsIntegers] Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.NaturalGas as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.NaturalGas) instead! [Non-standard Modelica: --allowNonStandardModelica=nonStdEnumerationAsIntegers] Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.DistrictHeating as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.DistrictHeating) instead! [Non-standard Modelica: --allowNonStandardModelica=nonStdEnumerationAsIntegers] Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Oil as Integer: 5. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Oil) instead! [Non-standard Modelica: --allowNonStandardModelica=nonStdEnumerationAsIntegers] Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Electricity as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Electricity) instead! [Non-standard Modelica: --allowNonStandardModelica=nonStdEnumerationAsIntegers] Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Solar as Integer: 7. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Solar) instead! [Non-standard Modelica: --allowNonStandardModelica=nonStdEnumerationAsIntegers] Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Biomass as Integer: 8. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Biomass) instead! [Non-standard Modelica: --allowNonStandardModelica=nonStdEnumerationAsIntegers] Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Others as Integer: 10. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Others) instead! [Non-standard Modelica: --allowNonStandardModelica=nonStdEnumerationAsIntegers] Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! [Non-standard Modelica: --allowNonStandardModelica=nonStdEnumerationAsIntegers] Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! [Non-standard Modelica: --allowNonStandardModelica=nonStdEnumerationAsIntegers] Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! [Non-standard Modelica: --allowNonStandardModelica=nonStdEnumerationAsIntegers] Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Renewable as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Renewable) instead! [Non-standard Modelica: --allowNonStandardModelica=nonStdEnumerationAsIntegers] Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! [Non-standard Modelica: --allowNonStandardModelica=nonStdEnumerationAsIntegers] Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Generic as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Generic) instead! [Non-standard Modelica: --allowNonStandardModelica=nonStdEnumerationAsIntegers] Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! [Non-standard Modelica: --allowNonStandardModelica=nonStdEnumerationAsIntegers] Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Renewable as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Renewable) instead! [Non-standard Modelica: --allowNonStandardModelica=nonStdEnumerationAsIntegers] Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! [Non-standard Modelica: --allowNonStandardModelica=nonStdEnumerationAsIntegers] Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! [Non-standard Modelica: --allowNonStandardModelica=nonStdEnumerationAsIntegers] Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! [Non-standard Modelica: --allowNonStandardModelica=nonStdEnumerationAsIntegers] Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! [Non-standard Modelica: --allowNonStandardModelica=nonStdEnumerationAsIntegers] Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Storage as Integer: 5. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Storage) instead! [Non-standard Modelica: --allowNonStandardModelica=nonStdEnumerationAsIntegers] Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! [Non-standard Modelica: --allowNonStandardModelica=nonStdEnumerationAsIntegers] Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! [Non-standard Modelica: --allowNonStandardModelica=nonStdEnumerationAsIntegers] Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! [Non-standard Modelica: --allowNonStandardModelica=nonStdEnumerationAsIntegers] Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Renewable as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Renewable) instead! [Non-standard Modelica: --allowNonStandardModelica=nonStdEnumerationAsIntegers] Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Generic as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Generic) instead! [Non-standard Modelica: --allowNonStandardModelica=nonStdEnumerationAsIntegers] Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! [Non-standard Modelica: --allowNonStandardModelica=nonStdEnumerationAsIntegers] Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! [Non-standard Modelica: --allowNonStandardModelica=nonStdEnumerationAsIntegers] Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! [Non-standard Modelica: --allowNonStandardModelica=nonStdEnumerationAsIntegers] Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Renewable as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Renewable) instead! [Non-standard Modelica: --allowNonStandardModelica=nonStdEnumerationAsIntegers] Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Generic as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Generic) instead! [Non-standard Modelica: --allowNonStandardModelica=nonStdEnumerationAsIntegers] Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! [Non-standard Modelica: --allowNonStandardModelica=nonStdEnumerationAsIntegers] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-ClaRa/VLEFluidFunctions.mo:524:13-528:28:writable] Warning: Pure function 'TILMedia.Internals.VLEFluidConfigurations.FullyMixtureCompatible.VLEFluidFunctions.specificEnthalpy_pTxi' contains a call to impure function 'TILMedia.Internals.VLEFluidFunctions.specificEnthalpy_pTxi'. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-ClaRa/VLEFluidFunctions.mo:177:13-181:19:writable] Warning: Pure function 'TILMedia.Internals.VLEFluidConfigurations.FullyMixtureCompatible.VLEFluidFunctions.density_phxi' contains a call to impure function 'TILMedia.Internals.VLEFluidFunctions.density_phxi'. Notification: Performance of NFTyping.typeBindings: time 0.01605/0.1377, allocations: 0 / 0, free: 0 / 0 Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! [Non-standard Modelica: --allowNonStandardModelica=nonStdEnumerationAsIntegers] Warning: Allowing usage of enumeration expression: CHP_Plant_two_fuels.typeOfResource as Integer: CAST(Integer, CHP_Plant_two_fuels.typeOfResource). This is non-standard Modelica, use Integer(CHP_Plant_two_fuels.typeOfResource) instead! [Non-standard Modelica: --allowNonStandardModelica=nonStdEnumerationAsIntegers] Warning: Allowing usage of enumeration expression: CHP_Plant_two_fuels.typeOfPrimaryEnergyCarrier as Integer: CAST(Integer, CHP_Plant_two_fuels.typeOfPrimaryEnergyCarrier). This is non-standard Modelica, use Integer(CHP_Plant_two_fuels.typeOfPrimaryEnergyCarrier) instead! [Non-standard Modelica: --allowNonStandardModelica=nonStdEnumerationAsIntegers] Warning: Allowing usage of enumeration expression: CHP_Plant_two_fuels.typeOfPrimaryEnergyCarrierHeat as Integer: CAST(Integer, CHP_Plant_two_fuels.typeOfPrimaryEnergyCarrierHeat). This is non-standard Modelica, use Integer(CHP_Plant_two_fuels.typeOfPrimaryEnergyCarrierHeat) instead! [Non-standard Modelica: --allowNonStandardModelica=nonStdEnumerationAsIntegers] Notification: Performance of NFTyping.typeClassSections: time 0.01181/0.1495, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFFlatten.flatten: time 0.01531/0.1648, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFFlatten.resolveConnections: time 0.007953/0.1728, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFEvalConstants.evaluate: time 0.01919/0.192, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFSimplifyModel.simplify: time 0.00908/0.2011, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFPackage.collectConstants: time 0.002422/0.2035, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFFlatten.collectFunctions: time 0.006/0.2095, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFScalarize.scalarize: time 0.004488/0.214, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFVerifyModel.verify: time 0.006626/0.2206, allocations: 0 / 0, free: 0 / 0 [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Components/Statistics/Collectors/GlobalCollectors/GwpEmissionsStatistics.mo:77:53-77:84:writable] Error: Variable simCenter.expertMode not found in scope GwpEmissionsStatistics. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Components/Statistics/Collectors/GlobalCollectors/GwpEmissionsStatistics.mo:81:53-81:84:writable] Error: Variable simCenter.expertMode not found in scope GwpEmissionsStatistics. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Components/Statistics/Collectors/GlobalCollectors/EconomicStatistics.mo:40:70-40:85:writable] Error: Variable True not found in scope EconomicStatistics. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/ModelStatistics.mo:103:71-103:86:writable] Error: Variable True not found in scope ModelStatistics. Notification: Performance of NFConvertDAE.convert: time 0.09615/0.3168, allocations: 0 / 0, free: 0 / 0 Notification: Performance of FrontEnd - DAE generated: time 0.00295/0.3197, allocations: 0 / 0, free: 0 / 0 Notification: Performance of FrontEnd: time 3.196e-06/0.3197, allocations: 0 / 0, free: 0 / 0 Notification: Performance of Transformations before backend: time 0.0001013/0.3198, allocations: 0 / 0, free: 0 / 0 Error: Too many equations, over-determined system. The model has 1304 equation(s) and 1296 variable(s). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Producer/Gas/Electrolyzer/Systems/Check/TestElectrolyzerAndCavern.mo:136:3-139:22:writable] Warning: Equation 141 (size: 1) CHP_Plant_two_fuels.outlet.p = sink.steam_a.p is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: CHP_Plant_two_fuels.outlet.p, sink.steam_a.p Equations used to solve those variables: Equation 678 (size: 1): CHP_Plant_two_fuels.eye.p = 1e-5 * CHP_Plant_two_fuels.outlet.p Equation 818 (size: 1): sink.steam_a.p = sink.p_in [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-ClaRa/BaseClasses/PartialVLEFluid_ph.mo:39:3-41:43:writable] Warning: Equation 925 (size: 1) CHP_Plant_two_fuels.T_out_sensor.fluid.h = $OMC$inStreamDiv(($OMC$PositiveMax(CHP_Plant_two_fuels.outlet.m_flow, 1e-7) * sink.steam_a.h_outflow + $OMC$PositiveMax(-CHP_Plant_two_fuels.HX.outlet.m_flow, 1e-7) * CHP_Plant_two_fuels.HX.outlet.h_outflow) / ($OMC$PositiveMax(CHP_Plant_two_fuels.outlet.m_flow, 1e-7) + $OMC$PositiveMax(-CHP_Plant_two_fuels.HX.outlet.m_flow, 1e-7)), CHP_Plant_two_fuels.T_out_sensor.port.h_outflow) is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: CHP_Plant_two_fuels.outlet.m_flow, CHP_Plant_two_fuels.T_out_sensor.port.h_outflow, CHP_Plant_two_fuels.T_out_sensor.fluid.h, CHP_Plant_two_fuels.HX.outlet.m_flow, CHP_Plant_two_fuels.HX.outlet.h_outflow, sink.steam_a.h_outflow Equations used to solve those variables: Equation 86 (size: 1): CHP_Plant_two_fuels.outlet.h_outflow = $OMC$inStreamDiv(($OMC$PositiveMax(-CHP_Plant_two_fuels.HX.outlet.m_flow, 1e-7) * CHP_Plant_two_fuels.HX.outlet.h_outflow + $OMC$PositiveMax(-CHP_Plant_two_fuels.T_out_sensor.port.m_flow, 1e-7) * CHP_Plant_two_fuels.T_out_sensor.port.h_outflow) / ($OMC$PositiveMax(-CHP_Plant_two_fuels.HX.outlet.m_flow, 1e-7) + $OMC$PositiveMax(-CHP_Plant_two_fuels.T_out_sensor.port.m_flow, 1e-7)), 0) Equation 216 (size: 1): CHP_Plant_two_fuels.HX.outlet.m_flow + CHP_Plant_two_fuels.T_out_sensor.port.m_flow - CHP_Plant_two_fuels.outlet.m_flow = 0.0 Equation 426 (size: 1): CHP_Plant_two_fuels.T_out_sensor.fluid.T = TILMedia.Internals.VLEFluidConfigurations.FullyMixtureCompatible.VLEFluidObjectFunctions.temperature_phxi(CHP_Plant_two_fuels.T_out_sensor.fluid.p, CHP_Plant_two_fuels.T_out_sensor.fluid.h, {}, CHP_Plant_two_fuels.T_out_sensor.fluid.vleFluidPointer) Equation 448 (size: 1): CHP_Plant_two_fuels.T_out_sensor.port.h_outflow = 0.0 Equation 681 (size: 1): CHP_Plant_two_fuels.eye.m_flow = -CHP_Plant_two_fuels.outlet.m_flow Equation 817 (size: 1): sink.steam_a.h_outflow = sink.fluidOut.h [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Basics/ControlVolumes/Fundamentals/SpacialDistribution/IdeallyStirred.mo:27:3-27:26:writable] Warning: Equation 625 (size: 1) CHP_Plant_two_fuels.HX.phaseBorder.h_outflow = CHP_Plant_two_fuels.HX.iCom.h_bulk is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: CHP_Plant_two_fuels.HX.phaseBorder.h_outflow, CHP_Plant_two_fuels.HX.iCom.h_bulk Equations used to solve those variables: Equation 624 (size: 1): CHP_Plant_two_fuels.HX.phaseBorder.h_inflow = CHP_Plant_two_fuels.HX.iCom.h_bulk Equation 642 (size: 1): CHP_Plant_two_fuels.HX.outlet.h_outflow = CHP_Plant_two_fuels.HX.phaseBorder.h_outflow [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Producer/Combined/LargeScaleCHP/Base/PartialCHP.mo:338:3-339:127:writable] Warning: Equation 87 (size: 1) CHP_Plant_two_fuels.inlet.p = CHP_Plant_two_fuels.T_in_sensor.port.p is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: CHP_Plant_two_fuels.inlet.p, CHP_Plant_two_fuels.T_in_sensor.port.p Equations used to solve those variables: Equation 140 (size: 1): CHP_Plant_two_fuels.inlet.p = source.steam_a.p Equation 926 (size: 1): CHP_Plant_two_fuels.T_in_sensor.fluid.p = CHP_Plant_two_fuels.T_in_sensor.port.p [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Producer/Combined/LargeScaleCHP/Base/PartialCHP.mo:338:3-339:127:writable] Warning: Equation 88 (size: 1) CHP_Plant_two_fuels.inlet.p = CHP_Plant_two_fuels.HX.inlet.p is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: CHP_Plant_two_fuels.inlet.p, CHP_Plant_two_fuels.HX.inlet.p Equations used to solve those variables: Equation 140 (size: 1): CHP_Plant_two_fuels.inlet.p = source.steam_a.p Equation 645 (size: 1): CHP_Plant_two_fuels.HX.inlet.p = CHP_Plant_two_fuels.HX.p + CHP_Plant_two_fuels.HX.pressureLoss.Delta_p + CHP_Plant_two_fuels.HX.phaseBorder.Delta_p_geo_in [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Producer/Combined/LargeScaleCHP/H2CofiringCHP.mo:178:3-178:128:writable] Warning: Equation 94 (size: 1) CHP_Plant_two_fuels.steamGenerator.y = CHP_Plant_two_fuels.product1.u1 is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: CHP_Plant_two_fuels.steamGenerator.y, CHP_Plant_two_fuels.product1.u1 Equations used to solve those variables: Equation 648 (size: 1): der(CHP_Plant_two_fuels.steamGenerator.y) = (CHP_Plant_two_fuels.steamGenerator.k * CHP_Plant_two_fuels.steamGenerator.u - CHP_Plant_two_fuels.steamGenerator.y) / CHP_Plant_two_fuels.steamGenerator.T Equation 652 (size: 1): CHP_Plant_two_fuels.product1.y = CHP_Plant_two_fuels.product1.u1 * CHP_Plant_two_fuels.product1.u2 [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Producer/Combined/LargeScaleCHP/H2CofiringCHP.mo:178:3-178:128:writable] Warning: Equation 95 (size: 1) CHP_Plant_two_fuels.steamGenerator.y = CHP_Plant_two_fuels.product.u1 is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: CHP_Plant_two_fuels.steamGenerator.y, CHP_Plant_two_fuels.product.u1 Equations used to solve those variables: Equation 648 (size: 1): der(CHP_Plant_two_fuels.steamGenerator.y) = (CHP_Plant_two_fuels.steamGenerator.k * CHP_Plant_two_fuels.steamGenerator.u - CHP_Plant_two_fuels.steamGenerator.y) / CHP_Plant_two_fuels.steamGenerator.T Equation 651 (size: 1): CHP_Plant_two_fuels.product.y = CHP_Plant_two_fuels.product.u1 * CHP_Plant_two_fuels.product.u2 " [Timeout remaining time 900] [Calling sys.exit(0), Time elapsed: 1.857965962961316]