startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=2500 stepSize=34.56 wasm-jit simulation: simulate(TransiEnt.Producer.Electrical.Photovoltaics.QuasiStationary.Check.TestConstantEfficiencyPVModule,startTime=0,stopTime=86400,tolerance=1e-06,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="TransiEnt_TransiEnt.Producer.Electrical.Photovoltaics.QuasiStationary.Check.TestConstantEfficiencyPVModule",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS") LOG_STDOUT | warning | The nominal value of simCenter.rh_amb is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables//ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ambient/GHI_Hamburg_3600s_TMY.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/ambient/GHI_Hamburg_3600s_TMY.txt LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables//ambient/Temperature_Hamburg-Billwerder_900s_01012012_31122012.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/ambient/Temperature_Hamburg-Billwerder_900s_01012012_31122012.txt LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables//ambient/Wind_Hamburg_3600s_TMY.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/ambient/Wind_Hamburg_3600s_TMY.txt LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 7.7275e-05s [ 0.2%] pre-initialization | | | | | | 0.0359551s [ 80.9%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0.000307935s [ 0.7%] solver (excl. callbacks) | | | | | | 1.843e-06s [ 0.0%] creating output-file | | | | | | 0.000543756s [ 1.2%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 0.00757839s [ 17.0%] simulation | | | | | | 0.0444644s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 2 time events | | | | | solver: dassl | | | | | | 101 steps taken | | | | | | 129 calls of functionODE | | | | | | 83 evaluations of jacobian | | | | | | 5 error test failures | | | | | | 0 convergence test failures | | | | | | 9.6341e-05s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.