startTime=0 stopTime=3.1536e+07 tolerance=1e-08 numberOfIntervals=8760 stepSize=3600 wasm-jit simulation: simulate(TransiEnt.Producer.Electrical.Photovoltaics.Advanced_PV.Check.Test_Advanced_PV_WeatherHamburg,startTime=0,stopTime=3.1536e+07,tolerance=1e-08,numberOfIntervals=8760,outputFormat="empty",variableFilter="",fileNamePrefix="TransiEnt_TransiEnt.Producer.Electrical.Photovoltaics.Advanced_PV.Check.Test_Advanced_PV_WeatherHamburg",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS") LOG_STDOUT | warning | The nominal value of simCenter.rh_amb is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables//ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ambient/DNI_Hamburg_3600s_TMY.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/ambient/DNI_Hamburg_3600s_TMY.txt LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ambient/DHI_Hamburg_3600s_TMY.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/ambient/DHI_Hamburg_3600s_TMY.txt LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables//ambient/Temperature_Hamburg-Fuhlsbuettel_3600s_01012012_31122012.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/ambient/Temperature_Hamburg-Fuhlsbuettel_3600s_01012012_31122012.txt LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables//ambient/Wind_Hamburg_3600s_TMY.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/ambient/Wind_Hamburg_3600s_TMY.txt LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ambient/GHI_Hamburg_3600s_TMY.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/ambient/GHI_Hamburg_3600s_TMY.txt LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 0.000108073s [ 0.0%] pre-initialization | | | | | | 0.0408963s [ 2.6%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0.208032s [ 13.3%] solver (excl. callbacks) | | | | | | 6.031e-06s [ 0.0%] creating output-file | | | | | | 0.587552s [ 37.4%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 0.732328s [ 46.7%] simulation | | | | | | 1.56892s [100.0%] total | | | | | events | | | | | | 4122 state events | | | | | | 3 time events | | | | | solver: dassl | | | | | | 140264 steps taken | | | | | | 220704 calls of functionODE | | | | | | 68826 evaluations of jacobian | | | | | | 15430 error test failures | | | | | | 0 convergence test failures | | | | | | 0.144789s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.