startTime=0 stopTime=4.32e+06 tolerance=1e-06 numberOfIntervals=4800 stepSize=900 wasm-jit simulation: simulate(TransiEnt.Producer.Combined.SmallScaleCHP.SmallScaleCHP_simple.Check.TestSmallScaleCHP_simple_with_control,startTime=0,stopTime=4.32e+06,tolerance=1e-06,numberOfIntervals=4800,outputFormat="empty",variableFilter="",fileNamePrefix="TransiEnt_TransiEnt.Producer.Combined.SmallScaleCHP.SmallScaleCHP_simple.Check.TestSmallScaleCHP_simple_with_control",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS") Simulation execution failed for model: TransiEnt.Producer.Combined.SmallScaleCHP.SmallScaleCHP_simple.Check.TestSmallScaleCHP_simple_with_control LOG_STDOUT | warning | The nominal value of simCenter.rh_amb is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/electricity/Household/ElectricityDemand_20Households_measured_5-6MWh_3600s.csv LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/electricity/Household/ElectricityDemand_20Households_measured_5-6MWh_3600s.csv LOG_STDOUT | info | ... loading "Values" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/electricity/Household/ElectricityDemand_20Households_measured_5-6MWh_3600s.csv" LOG_ASSERT | debug | Table matrix "Values(8763,1)" does not have appropriate dimensions for time interpolation. LOG_ASSERT | info | simulation terminated by an assertion at initialization