startTime=0 stopTime=3.1536e+07 tolerance=1e-06 numberOfIntervals=35040 stepSize=900 wasm-jit simulation: simulate(TransiEnt.Grid.Heat.HeatGridAnalysis.OpenLoop_MassFlow_and_Pressure_Controlled,startTime=0,stopTime=3.1536e+07,tolerance=1e-06,numberOfIntervals=35040,outputFormat="empty",variableFilter="",fileNamePrefix="TransiEnt_TransiEnt.Grid.Heat.HeatGridAnalysis.OpenLoop_MassFlow_and_Pressure_Controlled",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS") Simulation execution failed for model: TransiEnt.Grid.Heat.HeatGridAnalysis.OpenLoop_MassFlow_and_Pressure_Controlled LOG_STDOUT | warning | The nominal value of Pump.pump.rpm is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of returnPump1.pump.rpm is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of returnPump2.pump.rpm is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of simCenter.rh_amb is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of Pump.pump.iCom.rpm_nom is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of Pump.pump.rpm_fixed is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of Pump.pump.rpm_nom is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of Pump.rpm_fixed is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of Pump.rpm_nom is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of returnPump1.pump.iCom.rpm_nom is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of returnPump1.pump.rpm_fixed is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of returnPump1.pump.rpm_nom is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of returnPump1.rpm_fixed is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of returnPump1.rpm_nom is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of returnPump2.pump.iCom.rpm_nom is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of returnPump2.pump.rpm_fixed is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of returnPump2.pump.rpm_nom is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of returnPump2.rpm_fixed is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of returnPump2.rpm_nom is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/\heat\TypicalHeatLoad_DHN_Normalized.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/\heat\TypicalHeatLoad_DHN_Normalized.txt LOG_ASSERT | debug | Not possible to open file "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/\heat\TypicalHeatLoad_DHN_Normalized.txt": No such file or directory LOG_ASSERT | info | simulation terminated by an assertion at initialization