startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=96 stepSize=900 wasm-jit simulation: simulate(TransiEnt.Components.Gas.Engines.Check.Test_Engine_idealGas,startTime=0,stopTime=86400,tolerance=1e-06,numberOfIntervals=96,outputFormat="empty",variableFilter="",fileNamePrefix="TransiEnt_TransiEnt.Components.Gas.Engines.Check.Test_Engine_idealGas",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS") Simulation execution failed for model: TransiEnt.Components.Gas.Engines.Check.Test_Engine_idealGas LOG_STDOUT | warning | The nominal value of simCenter.rh_amb is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables//ambient/Temperature_Hamburg-Fuhlsbuettel_3600s_01012012_31122012.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/ambient/Temperature_Hamburg-Fuhlsbuettel_3600s_01012012_31122012.txt LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables//ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | ... loading "default" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/heat/HeatingCurve_LHN_EonHanse.txt" LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | debug | division by zero at time 900, (a=0) / (b=0), where divisor b expression is: sink.gasPort.m_flow LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Basics/Interfaces/Gas/IdealGasEnthPort.mo:45:3-45:153:writable] | | | | The following assertion has been violated at time 900.000000 | | | | ((engine.gasPortOut.xi_outflow[1] >= 0.0 and engine.gasPortOut.xi_outflow[1] <= 1.0), engine.gasPortOut.xi_outflow[1]=NaN) --> "Variable violating min/max constraint: 0.0 <= engine.gasPortOut.xi_outflow[1] <= 1.0, has value: NaN" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Basics/Interfaces/Gas/IdealGasEnthPort.mo:45:3-45:153:writable] | | | | The following assertion has been violated at time 900.000000 | | | | ((engine.gasPortOut.xi_outflow[2] >= 0.0 and engine.gasPortOut.xi_outflow[2] <= 1.0), engine.gasPortOut.xi_outflow[2]=NaN) --> "Variable violating min/max constraint: 0.0 <= engine.gasPortOut.xi_outflow[2] <= 1.0, has value: NaN" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Basics/Interfaces/Gas/IdealGasEnthPort.mo:45:3-45:153:writable] | | | | The following assertion has been violated at time 900.000000 | | | | ((engine.gasPortOut.xi_outflow[5] >= 0.0 and engine.gasPortOut.xi_outflow[5] <= 1.0), engine.gasPortOut.xi_outflow[5]=NaN) --> "Variable violating min/max constraint: 0.0 <= engine.gasPortOut.xi_outflow[5] <= 1.0, has value: NaN" LOG_ASSERT | debug | division by zero at time 0, (a=0) / (b=0), where divisor b expression is: sink.gasPort.m_flow LOG_ERROR | error | wasm-jit simulation failed: CodegenWasmJit: wasm engine error