startTime=432000 stopTime=864000 tolerance=1e-07 numberOfIntervals=480 stepSize=900 wasm-jit simulation: simulate(Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.ASHRAE2006Winter_Autosizing,startTime=432000,stopTime=864000,tolerance=1e-07,numberOfIntervals=480,outputFormat="mat",variableFilter="time|flo.sou.TAir|flo.eas.TAir|flo.nor.TAir|flo.wes.TAir|flo.cor.TAir|hvac.TSetRoo.setPoiHea.y|hvac.TSetRoo.setPoiCoo.y|hvac.fanSup.y|hvac.VAVBox.[0-9,]+..vav.y_actual|hvac.damOut.y|hvac.VAVBox.[0-9,]+..TSup|hvac.res.EFan|hvac.res.EHea|hvac.res.ECoo",fileNamePrefix="Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.ASHRAE2006Winter_Autosizing",simflags="-abortSlowSimulation -alarm=240 -emit_protected -ignoreHideResult -lv LOG_STATS") LOG_STDOUT | warning | The nominal value of flo.cor.vol.m is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of flo.wes.vol.m is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of flo.nor.vol.m is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of flo.eas.vol.m is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of flo.sou.vol.m is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.conEco.VOut_flow is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.splRetOut.vol.dynBal.m is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.VAVBox[5].terHea.C2_flow is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.VAVBox[5].terHea.C1_flow is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.VAVBox[5].VSup_flow is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.VAVBox[4].terHea.C2_flow is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.VAVBox[4].terHea.C1_flow is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.VAVBox[4].VSup_flow is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.VAVBox[3].terHea.C2_flow is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.VAVBox[3].terHea.C1_flow is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.VAVBox[3].VSup_flow is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.VAVBox[2].terHea.C2_flow is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.VAVBox[2].terHea.C1_flow is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.VAVBox[2].VSup_flow is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.VAVBox[1].terHea.C2_flow is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.VAVBox[1].terHea.C1_flow is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.VAVBox[1].VSup_flow is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.senRetFlo.V_flow is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.senSupFlo.V_flow is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.fanSup.vol.dynBal.m is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.cooCoi.heaCooHum_u.vol.dynBal.m is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.heaCoi.C2_flow is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.heaCoi.C1_flow is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of flo.att.vol.m is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.pumHeaCoi.vol.dynBal.m is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.pumCooCoi.vol.dynBal.m is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.cooCoi.heaCoo.vol.dynBal.m is 0, but it must be nonzero and finite. The solvers use 1.0 instead. EnergyPlus Starting EnergyPlus, Version 24.2.0-638b8408fd (No OpenGL), YMD=2026.11.18 17:49 Initializing Response Factors Calculating CTFs for "ATTIC NON-RES FLOOR" Calculating CTFs for "ATTIC NON-RES ROOF" Calculating CTFs for "INTERIORFURNISHINGS" Calculating CTFs for "MASS NON-RES EXT WALL" Calculating CTFs for "EXT-SLAB" Calculating CTFs for "INT-WALLS" Initializing Window Optical Properties Initializing Solar Calculations Allocate Solar Module Arrays Initializing Zone and Enclosure Report Variables Initializing Surface (Shading) Report Variables Determining Shadowing Combinations Computing Window Shade Absorption Factors Proceeding with Initializing Solar Calculations Initializing Surfaces Initializing Outdoor environment for Surfaces Setting up Surface Reporting Variables Initializing Temperature and Flux Histories Initializing Window Shading Computing Interior Absorption Factors Computing Interior Diffuse Solar Absorption Factors Initializing Solar Heat Gains Initializing Internal Heat Gains Initializing Interior Solar Distribution Initializing Interior Convection Coefficients Gathering Information for Predefined Reporting Completed Initializing Surface Heat Balance Calculate Outside Surface Heat Balance Calculate Inside Surface Heat Balance Calculate Air Heat Balance Initializing HVAC Warming up Warming up Warming up Warming up Warming up Warming up Performing Zone Sizing Simulation ...for Sizing Period: #1 CHICAGO ANN CLG .4% CONDNS WB=>MDB Warming up Warming up Warming up Warming up Warming up Warming up Performing Zone Sizing Simulation ...for Sizing Period: #2 CHICAGO ANN HTG 99.6% CONDNS DB Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Warming up {11} Starting Simulation at 01/06/2006 for SPAWN-RUNPERIOD LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 432060.000000 | | | | ((hvac.fanSup.etaHyd >= 0.0), hvac.fanSup.etaHyd=-5.415971555611149e-19) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.etaHyd, has value: -5.41597e-19" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 432060.000000 | | | | ((hvac.fanSup.heaDis.etaHyd >= 0.0), hvac.fanSup.heaDis.etaHyd=-9.931864235754651e-15) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.heaDis.etaHyd, has value: -9.93186e-15" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 436800.000000 | | | | ((hvac.VAVBox[1].VSup_flow >= 0.0), hvac.VAVBox[1].VSup_flow=-5.945794700065779e-10) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[1].VSup_flow, has value: -5.94579e-10" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 436800.000000 | | | | ((hvac.VAVBox[2].VSup_flow >= 0.0), hvac.VAVBox[2].VSup_flow=-5.277548063337368e-10) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[2].VSup_flow, has value: -5.27755e-10" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 436800.000000 | | | | ((hvac.VAVBox[3].VSup_flow >= 0.0), hvac.VAVBox[3].VSup_flow=-5.220704469136754e-10) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[3].VSup_flow, has value: -5.2207e-10" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 436800.000000 | | | | ((hvac.VAVBox[4].VSup_flow >= 0.0), hvac.VAVBox[4].VSup_flow=-5.273942449456725e-10) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[4].VSup_flow, has value: -5.27394e-10" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 436800.000000 | | | | ((hvac.VAVBox[5].VSup_flow >= 0.0), hvac.VAVBox[5].VSup_flow=-5.072464693354838e-10) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[5].VSup_flow, has value: -5.07246e-10" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 500451.565352 | | | | ((hvac.pumHeaCoi.etaHyd >= 0.0), hvac.pumHeaCoi.etaHyd=-1.0208876524275818e-24) --> "Variable violating min constraint: 0.0 <= hvac.pumHeaCoi.etaHyd, has value: -1.02089e-24" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:117:3-118:81:writable] | | | | The following assertion has been violated at time 500451.565352 | | | | ((hvac.pumHeaCoi.m_flow >= 0.0 and hvac.pumHeaCoi.m_flow <= 1e5), hvac.pumHeaCoi.m_flow=-3.2975581223321765e-13) --> "Variable violating min/max constraint: 0.0 <= hvac.pumHeaCoi.m_flow <= 1e5, has value: -3.29756e-13" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 500451.565352 | | | | ((hvac.pumHeaCoi.heaDis.etaHyd >= 0.0), hvac.pumHeaCoi.heaDis.etaHyd=-1.2796281127879678e-23) --> "Variable violating min constraint: 0.0 <= hvac.pumHeaCoi.heaDis.etaHyd, has value: -1.27963e-23" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 501000.000000 | | | | ((hvac.fanSup.eff.yMot >= 0.0), hvac.fanSup.eff.yMot=-1.4177324942154034e-219) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.eff.yMot, has value: -1.41773e-219" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 501000.000000 | | | | ((hvac.pumHeaCoi.eff.yMot >= 0.0), hvac.pumHeaCoi.eff.yMot=-1.093313597382182e-167) --> "Variable violating min constraint: 0.0 <= hvac.pumHeaCoi.eff.yMot, has value: -1.09331e-167" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Utilities/Psychrometrics/TDewPoi_pW.mo:5:3-9:74:writable] | | | | The following assertion has been violated at time 539236.648867 | | | | ((hvac.cooCoi.dryWetCalcs.TDewIn.p_w >= 100.0), hvac.cooCoi.dryWetCalcs.TDewIn.p_w=88.25291900850338) --> "Variable violating min constraint: 100.0 <= hvac.cooCoi.dryWetCalcs.TDewIn.p_w, has value: 88.2529" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 4.7309e-05s [ 0.0%] pre-initialization | | | | | | 5.75357s [ 37.3%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0.607235s [ 3.9%] solver (excl. callbacks) | | | | | | 0.00754709s [ 0.0%] creating output-file | | | | | | 1.23971s [ 8.0%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 7.80389s [ 50.6%] simulation | | | | | | 15.412s [100.0%] total | | | | | events | | | | | | 111 state events | | | | | | 740 time events | | | | | solver: dassl | | | | | | 47774 steps taken | | | | | | 71605 calls of functionODE | | | | | | 17743 evaluations of jacobian | | | | | | 2577 error test failures | | | | | | 998 convergence test failures | | | | | | 6.69065s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing final SQL reports EnergyPlus Run Time=00hr 00min 10.10sec EnergyPlus Completed Successfully.