startTime=1.6848e+07 stopTime=1.728e+07 tolerance=1e-07 numberOfIntervals=2500 stepSize=172.8 wasm-jit simulation: simulate(Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.ASHRAE2006Summer,startTime=1.6848e+07,stopTime=1.728e+07,tolerance=1e-07,numberOfIntervals=2500,outputFormat="mat",variableFilter="time|flo.sou.TAir|flo.eas.TAir|flo.nor.TAir|flo.wes.TAir|flo.cor.TAir|hvac.TSetRoo.setPoiHea.y|hvac.TSetRoo.setPoiCoo.y|hvac.fanSup.y|hvac.VAVBox.[0-9,]+..vav.y_actual|hvac.damOut.y|hvac.VAVBox.[0-9,]+..TSup|hvac.res.EFan|hvac.res.EHea|hvac.res.ECoo",fileNamePrefix="Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.ASHRAE2006Summer",simflags="-abortSlowSimulation -alarm=240 -emit_protected -ignoreHideResult -lv LOG_STATS") LOG_STDOUT | warning | The nominal value of flo.cor.vol.m is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of flo.wes.vol.m is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of flo.nor.vol.m is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of flo.eas.vol.m is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of flo.sou.vol.m is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of flo.att.vol.m is 0, but it must be nonzero and finite. The solvers use 1.0 instead. EnergyPlus Starting EnergyPlus, Version 24.2.0-638b8408fd (No OpenGL), YMD=2026.11.18 17:49 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Warming up {11} Starting Simulation at 07/15/2006 for SPAWN-RUNPERIOD LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 16848060.000000 | | | | ((hvac.fanSup.etaHyd >= 0.0), hvac.fanSup.etaHyd=-2.1156414106244053e-21) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.etaHyd, has value: -2.11564e-21" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 16848060.000000 | | | | ((hvac.fanSup.heaDis.etaHyd >= 0.0), hvac.fanSup.heaDis.etaHyd=-5.2154397595346435e-17) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.heaDis.etaHyd, has value: -5.21544e-17" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 16848172.800000 | | | | ((hvac.VAVBox[1].VSup_flow >= 0.0), hvac.VAVBox[1].VSup_flow=-6.059197458435664e-16) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[1].VSup_flow, has value: -6.0592e-16" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 16848172.800000 | | | | ((hvac.VAVBox[2].VSup_flow >= 0.0), hvac.VAVBox[2].VSup_flow=-9.230817964082193e-17) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[2].VSup_flow, has value: -9.23082e-17" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 16848172.800000 | | | | ((hvac.VAVBox[3].VSup_flow >= 0.0), hvac.VAVBox[3].VSup_flow=-6.059197458435684e-16) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[3].VSup_flow, has value: -6.0592e-16" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 16848172.800000 | | | | ((hvac.VAVBox[4].VSup_flow >= 0.0), hvac.VAVBox[4].VSup_flow=-9.230817964082193e-17) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[4].VSup_flow, has value: -9.23082e-17" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 16848172.800000 | | | | ((hvac.VAVBox[5].VSup_flow >= 0.0), hvac.VAVBox[5].VSup_flow=-7.992940989771825e-16) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[5].VSup_flow, has value: -7.99294e-16" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:78:3-83:35:writable] | | | | The following assertion has been violated at time 16916428.800000 | | | | ((hvac.cooCoi.SHR >= 0.0 and hvac.cooCoi.SHR <= 1.0), hvac.cooCoi.SHR=-9.163508710664582e-9) --> "Variable violating min/max constraint: 0.0 <= hvac.cooCoi.SHR <= 1.0, has value: -9.16351e-09" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 16916428.800000 | | | | ((hvac.fanSup.eff.yMot >= 0.0), hvac.fanSup.eff.yMot=-1.823442378160935e-50) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.eff.yMot, has value: -1.82344e-50" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 16916601.600000 | | | | ((hvac.pumCooCoi.etaHyd >= 0.0), hvac.pumCooCoi.etaHyd=-1.4172551800935367e-24) --> "Variable violating min constraint: 0.0 <= hvac.pumCooCoi.etaHyd, has value: -1.41726e-24" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 16916601.600000 | | | | ((hvac.pumCooCoi.heaDis.etaHyd >= 0.0), hvac.pumCooCoi.heaDis.etaHyd=-2.0478734580269373e-22) --> "Variable violating min constraint: 0.0 <= hvac.pumCooCoi.heaDis.etaHyd, has value: -2.04787e-22" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 16916601.600000 | | | | ((hvac.pumCooCoi.eff.yMot >= 0.0), hvac.pumCooCoi.eff.yMot=-5.557780874687127e-116) --> "Variable violating min constraint: 0.0 <= hvac.pumCooCoi.eff.yMot, has value: -5.55778e-116" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:117:3-118:81:writable] | | | | The following assertion has been violated at time 16916774.400000 | | | | ((hvac.pumCooCoi.m_flow >= 0.0 and hvac.pumCooCoi.m_flow <= 1e5), hvac.pumCooCoi.m_flow=-6.472474843391561e-12) --> "Variable violating min/max constraint: 0.0 <= hvac.pumCooCoi.m_flow <= 1e5, has value: -6.47247e-12" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 6.4571e-05s [ 0.0%] pre-initialization | | | | | | 5.62426s [ 22.1%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 1.06894s [ 4.2%] solver (excl. callbacks) | | | | | | 0.00860016s [ 0.0%] creating output-file | | | | | | 1.50492s [ 5.9%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 17.2512s [ 67.8%] simulation | | | | | | 25.458s [100.0%] total | | | | | events | | | | | | 43 state events | | | | | | 730 time events | | | | | solver: dassl | | | | | | 60172 steps taken | | | | | | 105830 calls of functionODE | | | | | | 42201 evaluations of jacobian | | | | | | 2751 error test failures | | | | | | 9073 convergence test failures | | | | | | 15.619s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing final SQL reports EnergyPlus Run Time=00hr 00min 20.11sec EnergyPlus Completed Successfully.