startTime=432000 stopTime=864000 tolerance=1e-07 numberOfIntervals=2500 stepSize=172.8 wasm-jit simulation: simulate(Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.ASHRAE2006Winter,startTime=432000,stopTime=864000,tolerance=1e-07,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="Buildings_13_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.ASHRAE2006Winter",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS") EnergyPlus Starting EnergyPlus, Version 24.2.0-9f1b36b00b, YMD=2026.11.18 17:24 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Warming up {11} Starting Simulation at 01/06/2006 for SPAWN-RUNPERIOD LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 432112.004491 | | | | ((hvac.fanSup.etaHyd >= 0.0), hvac.fanSup.etaHyd=-5.401658189303789e-22) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.etaHyd, has value: -5.40166e-22" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 432112.004491 | | | | ((hvac.fanSup.heaDis.etaHyd >= 0.0), hvac.fanSup.heaDis.etaHyd=-1.331606705485892e-17) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.heaDis.etaHyd, has value: -1.33161e-17" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 434937.600000 | | | | ((hvac.VAVBox[1].VSup_flow >= 0.0), hvac.VAVBox[1].VSup_flow=-4.508619626710994e-8) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[1].VSup_flow, has value: -4.50862e-08" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 434937.600000 | | | | ((hvac.VAVBox[2].VSup_flow >= 0.0), hvac.VAVBox[2].VSup_flow=-7.555734719666722e-9) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[2].VSup_flow, has value: -7.55573e-09" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 434937.600000 | | | | ((hvac.VAVBox[3].VSup_flow >= 0.0), hvac.VAVBox[3].VSup_flow=-4.508619626711216e-8) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[3].VSup_flow, has value: -4.50862e-08" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 434937.600000 | | | | ((hvac.VAVBox[4].VSup_flow >= 0.0), hvac.VAVBox[4].VSup_flow=-7.555734719666722e-9) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[4].VSup_flow, has value: -7.55573e-09" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 434937.600000 | | | | ((hvac.VAVBox[5].VSup_flow >= 0.0), hvac.VAVBox[5].VSup_flow=-5.9475131407004374e-8) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[5].VSup_flow, has value: -5.94751e-08" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 500428.800000 | | | | ((hvac.fanSup.eff.yMot >= 0.0), hvac.fanSup.eff.yMot=-5.321365216795214e-81) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.eff.yMot, has value: -5.32137e-81" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 500601.600000 | | | | ((hvac.pumHeaCoi.etaHyd >= 0.0), hvac.pumHeaCoi.etaHyd=-2.2263257101137528e-23) --> "Variable violating min constraint: 0.0 <= hvac.pumHeaCoi.etaHyd, has value: -2.22633e-23" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 500601.600000 | | | | ((hvac.pumHeaCoi.heaDis.etaHyd >= 0.0), hvac.pumHeaCoi.heaDis.etaHyd=-1.9796590543805844e-22) --> "Variable violating min constraint: 0.0 <= hvac.pumHeaCoi.heaDis.etaHyd, has value: -1.97966e-22" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 500947.200000 | | | | ((hvac.pumHeaCoi.eff.yMot >= 0.0), hvac.pumHeaCoi.eff.yMot=-6.596427583712327e-191) --> "Variable violating min constraint: 0.0 <= hvac.pumHeaCoi.eff.yMot, has value: -6.59643e-191" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Utilities/Psychrometrics/TDewPoi_pW.mo:5:3-9:74:writable] | | | | The following assertion has been violated at time 540019.197053 | | | | ((hvac.cooCoi.dryWetCalcs.TDewIn.p_w >= 100.0), hvac.cooCoi.dryWetCalcs.TDewIn.p_w=87.73155049619737) --> "Variable violating min constraint: 100.0 <= hvac.cooCoi.dryWetCalcs.TDewIn.p_w, has value: 87.7316" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:117:3-118:81:writable] | | | | The following assertion has been violated at time 587001.600000 | | | | ((hvac.pumHeaCoi.m_flow >= 0.0 and hvac.pumHeaCoi.m_flow <= 1e5), hvac.pumHeaCoi.m_flow=-4.529682928292762e-12) --> "Variable violating min/max constraint: 0.0 <= hvac.pumHeaCoi.m_flow <= 1e5, has value: -4.52968e-12" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 5.5795e-05s [ 0.0%] pre-initialization | | | | | | 5.64527s [ 34.5%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0.649887s [ 4.0%] solver (excl. callbacks) | | | | | | 1.7042e-05s [ 0.0%] creating output-file | | | | | | 1.29036s [ 7.9%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 8.79121s [ 53.7%] simulation | | | | | | 16.3768s [100.0%] total | | | | | events | | | | | | 63 state events | | | | | | 743 time events | | | | | solver: dassl | | | | | | 45987 steps taken | | | | | | 71196 calls of functionODE | | | | | | 20966 evaluations of jacobian | | | | | | 2241 error test failures | | | | | | 2257 convergence test failures | | | | | | 7.65836s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing final SQL reports EnergyPlus Run Time=00hr 00min 10.99sec EnergyPlus Completed Successfully.