startTime=1.6848e+07 stopTime=1.728e+07 tolerance=1e-07 numberOfIntervals=2500 stepSize=172.8 wasm-jit simulation: simulate(Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.ASHRAE2006Summer,startTime=1.6848e+07,stopTime=1.728e+07,tolerance=1e-07,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="Buildings_13_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.ASHRAE2006Summer",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS") EnergyPlus Starting EnergyPlus, Version 24.2.0-9f1b36b00b, YMD=2026.11.18 17:24 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Warming up {11} Starting Simulation at 07/15/2006 for SPAWN-RUNPERIOD LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 16848172.800000 | | | | ((hvac.VAVBox[1].VSup_flow >= 0.0), hvac.VAVBox[1].VSup_flow=-8.19113731105426e-16) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[1].VSup_flow, has value: -8.19114e-16" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 16848172.800000 | | | | ((hvac.VAVBox[2].VSup_flow >= 0.0), hvac.VAVBox[2].VSup_flow=-1.2478698365845661e-16) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[2].VSup_flow, has value: -1.24787e-16" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 16848172.800000 | | | | ((hvac.VAVBox[3].VSup_flow >= 0.0), hvac.VAVBox[3].VSup_flow=-8.191137311054249e-16) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[3].VSup_flow, has value: -8.19114e-16" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 16848172.800000 | | | | ((hvac.VAVBox[4].VSup_flow >= 0.0), hvac.VAVBox[4].VSup_flow=-1.2478698365845661e-16) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[4].VSup_flow, has value: -1.24787e-16" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 16848172.800000 | | | | ((hvac.VAVBox[5].VSup_flow >= 0.0), hvac.VAVBox[5].VSup_flow=-1.0805272086854605e-15) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[5].VSup_flow, has value: -1.08053e-15" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 16849036.800000 | | | | ((hvac.fanSup.etaHyd >= 0.0), hvac.fanSup.etaHyd=-4.923854721988069e-21) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.etaHyd, has value: -4.92385e-21" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 16849036.800000 | | | | ((hvac.fanSup.heaDis.etaHyd >= 0.0), hvac.fanSup.heaDis.etaHyd=-1.213819485583326e-16) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.heaDis.etaHyd, has value: -1.21382e-16" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:68:3-73:35:writable] | | | | The following assertion has been violated at time 16916428.800000 | | | | ((hvac.cooCoi.SHR >= 0.0 and hvac.cooCoi.SHR <= 1.0), hvac.cooCoi.SHR=-9.222088154204082e-9) --> "Variable violating min/max constraint: 0.0 <= hvac.cooCoi.SHR <= 1.0, has value: -9.22209e-09" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 16916601.600000 | | | | ((hvac.pumCooCoi.etaHyd >= 0.0), hvac.pumCooCoi.etaHyd=-3.574561302051295e-24) --> "Variable violating min constraint: 0.0 <= hvac.pumCooCoi.etaHyd, has value: -3.57456e-24" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 16916601.600000 | | | | ((hvac.pumCooCoi.heaDis.etaHyd >= 0.0), hvac.pumCooCoi.heaDis.etaHyd=-5.16508905197858e-22) --> "Variable violating min constraint: 0.0 <= hvac.pumCooCoi.heaDis.etaHyd, has value: -5.16509e-22" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 16916774.400000 | | | | ((hvac.fanSup.eff.yMot >= 0.0), hvac.fanSup.eff.yMot=-7.017422271550927e-176) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.eff.yMot, has value: -7.01742e-176" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 16916774.400000 | | | | ((hvac.pumCooCoi.eff.yMot >= 0.0), hvac.pumCooCoi.eff.yMot=-2.6706681378206995e-123) --> "Variable violating min constraint: 0.0 <= hvac.pumCooCoi.eff.yMot, has value: -2.67067e-123" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:117:3-118:81:writable] | | | | The following assertion has been violated at time 17089401.600000 | | | | ((hvac.pumCooCoi.m_flow >= 0.0 and hvac.pumCooCoi.m_flow <= 1e5), hvac.pumCooCoi.m_flow=-5.583260259547171e-14) --> "Variable violating min/max constraint: 0.0 <= hvac.pumCooCoi.m_flow <= 1e5, has value: -5.58326e-14" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 4.8251e-05s [ 0.0%] pre-initialization | | | | | | 5.61958s [ 21.6%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 1.16051s [ 4.5%] solver (excl. callbacks) | | | | | | 1.104e-05s [ 0.0%] creating output-file | | | | | | 1.44941s [ 5.6%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 17.8262s [ 68.4%] simulation | | | | | | 26.0558s [100.0%] total | | | | | events | | | | | | 41 state events | | | | | | 730 time events | | | | | solver: dassl | | | | | | 63083 steps taken | | | | | | 113520 calls of functionODE | | | | | | 46773 evaluations of jacobian | | | | | | 2783 error test failures | | | | | | 10559 convergence test failures | | | | | | 16.2252s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing final SQL reports EnergyPlus Run Time=00hr 00min 20.71sec EnergyPlus Completed Successfully.