startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=2500 stepSize=34.56 wasm-jit simulation: simulate(Buildings.Fluid.HydronicConfigurations.ActiveNetworks.Examples.Decoupling,startTime=0,stopTime=86400,tolerance=1e-06,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="Buildings_13_Buildings.Fluid.HydronicConfigurations.ActiveNetworks.Examples.Decoupling",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS") LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((con.pum.pumSpe.etaHyd >= 0.0), con.pum.pumSpe.etaHyd=-3.06680678823866e-38) --> "Variable violating min constraint: 0.0 <= con.pum.pumSpe.etaHyd, has value: -3.06681e-38" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((con.pum.pumSpe.heaDis.etaHyd >= 0.0), con.pum.pumSpe.heaDis.etaHyd=-1.381791200125191e-34) --> "Variable violating min constraint: 0.0 <= con.pum.pumSpe.heaDis.etaHyd, has value: -1.38179e-34" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:68:3-73:35:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((loa.loa.coi.SHR >= 0.0 and loa.loa.coi.SHR <= 1.0), loa.loa.coi.SHR=-1.7411776648587477e-31) --> "Variable violating min/max constraint: 0.0 <= loa.loa.coi.SHR <= 1.0, has value: -1.74118e-31" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:68:3-73:35:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((loa1.loa.coi.SHR >= 0.0 and loa1.loa.coi.SHR <= 1.0), loa1.loa.coi.SHR=-1.7229070605917099e-31) --> "Variable violating min/max constraint: 0.0 <= loa1.loa.coi.SHR <= 1.0, has value: -1.72291e-31" LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 79246.080000 | | | | ((con.pum.pumSpe.eff.yMot >= 0.0), con.pum.pumSpe.eff.yMot=-2.416737262571696e-33) --> "Variable violating min constraint: 0.0 <= con.pum.pumSpe.eff.yMot, has value: -2.41674e-33" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 79626.240000 | | | | ((pum.pumDp.eff.yMot >= 0.0), pum.pumDp.eff.yMot=-7.225588162121327e-29) --> "Variable violating min constraint: 0.0 <= pum.pumDp.eff.yMot, has value: -7.22559e-29" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 3.164e-05s [ 0.0%] pre-initialization | | | | | | 0.00082832s [ 0.4%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0.0147395s [ 7.5%] solver (excl. callbacks) | | | | | | 2.315e-06s [ 0.0%] creating output-file | | | | | | 0.00167193s [ 0.8%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 0.180495s [ 91.3%] simulation | | | | | | 0.197769s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 13 time events | | | | | solver: dassl | | | | | | 3301 steps taken | | | | | | 5078 calls of functionODE | | | | | | 871 evaluations of jacobian | | | | | | 236 error test failures | | | | | | 125 convergence test failures | | | | | | 0.0772235s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.