startTime=0 stopTime=604800 tolerance=1e-06 numberOfIntervals=2500 stepSize=241.92 wasm-jit simulation: simulate(Buildings.DHC.Examples.Combined.SeriesVariableFlowAgentControl,startTime=0,stopTime=604800,tolerance=1e-06,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="Buildings_13_Buildings.DHC.Examples.Combined.SeriesVariableFlowAgentControl",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS") Simulation execution failed for model: Buildings.DHC.Examples.Combined.SeriesVariableFlowAgentControl LOG_STDOUT | info | ... loading "tab1" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Resources/Data/DHC/Loads/Examples/SwissOffice_20190916.mos" LOG_STDOUT | info | ... loading "tab1" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Resources/Data/DHC/Loads/Examples/SwissResidential_20190916.mos" LOG_STDOUT | info | ... loading "tab1" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Resources/Data/DHC/Loads/Examples/SwissHospital_20190916.mos" LOG_ASSERT | error | Model error: Argument of log(u) was -1 should be > 0 LOG_STDOUT | warning | Non-Linear Solver try to handle a problem with a called assert. LOG_ASSERT | error | Model error: Argument of log(u) was -1 should be > 0 LOG_STDOUT | warning | Non-Linear Solver try to handle a problem with a called assert. LOG_ASSERT | error | Model error: Argument of log(u) was -1 should be > 0 LOG_STDOUT | warning | Non-Linear Solver try to handle a problem with a called assert. LOG_ASSERT | debug | Division by zero roughness / diameter in function context LOG_STDOUT | warning | Non-Linear Solver try to handle a problem with a called assert. LOG_ASSERT | debug | Division by zero roughness / diameter in function context LOG_STDOUT | warning | Non-Linear Solver try to handle a problem with a called assert. LOG_STDOUT | info | ... loading "TStep" from "tmp/temperatureResponseMatrix/cb5a516a14d0ff25ffce0ba805d0acd30c68bbadTStep.mat" LOG_STDOUT | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 0.000000. That might raise performance issues, for more information use -lv LOG_LS. LOG_STDOUT | info | ... loading "TStep" from "tmp/temperatureResponseMatrix/cb5a516a14d0ff25ffce0ba805d0acd30c68bbadTStep.mat" LOG_STDOUT | info | ... loading "TStep" from "tmp/temperatureResponseMatrix/cb5a516a14d0ff25ffce0ba805d0acd30c68bbadTStep.mat" LOG_STDOUT | info | ... loading "TStep" from "tmp/temperatureResponseMatrix/cb5a516a14d0ff25ffce0ba805d0acd30c68bbadTStep.mat" LOG_STDOUT | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 0.000000. That might raise performance issues, for more information use -lv LOG_LS. LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/FlowControlled_m_flow.mo:87:3-92:58:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | (((-pumDis.dp) <= pumDis.dpMax), pumDis.dp=-1.3843859691862527e6, pumDis.dpMax=341999.99999999994) --> "In SeriesVariableFlowAgentControl.pumDis: Model operates with head -dp = 1.38439e+06 Pa, | | | | exceeding the pressure allowed by the parameter SeriesVariableFlowAgentControl.pumDis.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | simulation terminated by an assertion at initialization