startTime=7.344e+06 stopTime=7.776e+06 tolerance=1e-07 numberOfIntervals=10613 stepSize=40.7048 wasm-jit simulation: simulate(Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.Guideline36Spring,startTime=7.344e+06,stopTime=7.776e+06,tolerance=1e-07,numberOfIntervals=10613,outputFormat="mat",variableFilter="time|flo.sou.TAir|flo.eas.TAir|flo.nor.TAir|flo.wes.TAir|flo.cor.TAir|hvac.TZonSet.[0-9,]+..TCooSet|hvac.TZonSet.[0-9,]+..THeaSet|hvac.fanSup.y|hvac.VAVBox.[0-9,]+..vav.y_actual|hvac.damOut.y|hvac.VAVBox.[0-9,]+..TSup|hvac.res.EFan|hvac.res.EHea|hvac.res.ECoo",fileNamePrefix="Buildings_12_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.Guideline36Spring",simflags="-abortSlowSimulation -alarm=450 -emit_protected -ignoreHideResult -lv LOG_STATS") EnergyPlus Starting EnergyPlus, Version 24.2.0-9f1b36b00b, YMD=2026.11.18 17:15 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Starting Simulation at 03/27/2006 for SPAWN-RUNPERIOD LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 7344000.000004 | | | | ((hvac.fanSup.etaHyd >= 0.0), hvac.fanSup.etaHyd=-8.443762532939878e-14) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.etaHyd, has value: -8.44376e-14" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 7344000.000004 | | | | ((hvac.fanSup.heaDis.etaHyd >= 0.0), hvac.fanSup.heaDis.etaHyd=-2.0815405963039047e-9) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.heaDis.etaHyd, has value: -2.08154e-09" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 7367700.000000 | | | | ((hvac.conVAV[1].ala.not2.y), hvac.conVAV[1].ala.not2.y=false) --> "Warning: airflow is less than 70% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 7367700.000000 | | | | ((hvac.conVAV[2].ala.not1.y), hvac.conVAV[2].ala.not1.y=false) --> "Warning: airflow is less than 50% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 7367700.000000 | | | | ((hvac.conVAV[2].ala.not2.y), hvac.conVAV[2].ala.not2.y=false) --> "Warning: airflow is less than 70% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 7367700.000000 | | | | ((hvac.conVAV[3].ala.not2.y), hvac.conVAV[3].ala.not2.y=false) --> "Warning: airflow is less than 70% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 7367700.000000 | | | | ((hvac.conVAV[4].ala.not1.y), hvac.conVAV[4].ala.not1.y=false) --> "Warning: airflow is less than 50% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 7367700.000000 | | | | ((hvac.conVAV[4].ala.not2.y), hvac.conVAV[4].ala.not2.y=false) --> "Warning: airflow is less than 70% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 7367700.000000 | | | | ((hvac.conVAV[5].ala.not2.y), hvac.conVAV[5].ala.not2.y=false) --> "Warning: airflow is less than 70% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:68:3-73:35:writable] | | | | The following assertion has been violated at time 7382343.917837 | | | | ((hvac.cooCoi.SHR >= 0.0 and hvac.cooCoi.SHR <= 1.0), hvac.cooCoi.SHR=-1.1726757605767978e-20) --> "Variable violating min/max constraint: 0.0 <= hvac.cooCoi.SHR <= 1.0, has value: -1.17268e-20" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 7382343.917837 | | | | ((hvac.pumCooCoi.etaHyd >= 0.0), hvac.pumCooCoi.etaHyd=-6.062987273842822e-28) --> "Variable violating min constraint: 0.0 <= hvac.pumCooCoi.etaHyd, has value: -6.06299e-28" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 7382343.917837 | | | | ((hvac.pumCooCoi.heaDis.etaHyd >= 0.0), hvac.pumCooCoi.heaDis.etaHyd=-8.76075874609847e-26) --> "Variable violating min constraint: 0.0 <= hvac.pumCooCoi.heaDis.etaHyd, has value: -8.76076e-26" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 7382420.558675 | | | | ((hvac.pumCooCoi.eff.yMot >= 0.0), hvac.pumCooCoi.eff.yMot=-1.900563757806821e-60) --> "Variable violating min constraint: 0.0 <= hvac.pumCooCoi.eff.yMot, has value: -1.90056e-60" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 7412409.036460 | | | | ((hvac.VAVBox[1].VSup_flow >= 0.0), hvac.VAVBox[1].VSup_flow=-8.704660354264265e-12) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[1].VSup_flow, has value: -8.70466e-12" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 7412409.036460 | | | | ((hvac.VAVBox[2].VSup_flow >= 0.0), hvac.VAVBox[2].VSup_flow=-4.258273366659411e-12) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[2].VSup_flow, has value: -4.25827e-12" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 7412409.036460 | | | | ((hvac.VAVBox[3].VSup_flow >= 0.0), hvac.VAVBox[3].VSup_flow=-8.704660354133205e-12) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[3].VSup_flow, has value: -8.70466e-12" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 7412409.036460 | | | | ((hvac.VAVBox[4].VSup_flow >= 0.0), hvac.VAVBox[4].VSup_flow=-4.258273366659411e-12) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[4].VSup_flow, has value: -4.25827e-12" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 7412409.036460 | | | | ((hvac.VAVBox[5].VSup_flow >= 0.0), hvac.VAVBox[5].VSup_flow=-1.1482727421441791e-11) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[5].VSup_flow, has value: -1.14827e-11" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 7412424.762084 | | | | ((hvac.fanSup.eff.yMot >= 0.0), hvac.fanSup.eff.yMot=-1.0119470411388015e-88) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.eff.yMot, has value: -1.01195e-88" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:117:3-118:81:writable] | | | | The following assertion has been violated at time 7412465.466880 | | | | ((hvac.pumCooCoi.m_flow >= 0.0 and hvac.pumCooCoi.m_flow <= 1e5), hvac.pumCooCoi.m_flow=-1.4977601218245442e-12) --> "Variable violating min/max constraint: 0.0 <= hvac.pumCooCoi.m_flow <= 1e5, has value: -1.49776e-12" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/Sensors/VolumeFlowRate.mo:19:3-25:24:writable] | | | | The following assertion has been violated at time 7413360.000000 | | | | ((hvac.VOut1.V_flow >= 0.0), hvac.VOut1.V_flow=-1.7749826694740118e-19) --> "Variable violating min constraint: 0.0 <= hvac.VOut1.V_flow, has value: -1.77498e-19" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 7498841.044003 | | | | ((hvac.pumHeaCoi.etaHyd >= 0.0), hvac.pumHeaCoi.etaHyd=-3.4195304622420894e-22) --> "Variable violating min constraint: 0.0 <= hvac.pumHeaCoi.etaHyd, has value: -3.41953e-22" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 7498841.044003 | | | | ((hvac.pumHeaCoi.heaDis.etaHyd >= 0.0), hvac.pumHeaCoi.heaDis.etaHyd=-3.040662204346503e-21) --> "Variable violating min constraint: 0.0 <= hvac.pumHeaCoi.heaDis.etaHyd, has value: -3.04066e-21" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 7498841.044003 | | | | ((hvac.pumHeaCoi.eff.yMot >= 0.0), hvac.pumHeaCoi.eff.yMot=-1.6264329562833708e-57) --> "Variable violating min constraint: 0.0 <= hvac.pumHeaCoi.eff.yMot, has value: -1.62643e-57" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:117:3-118:81:writable] | | | | The following assertion has been violated at time 7498881.748799 | | | | ((hvac.pumHeaCoi.m_flow >= 0.0 and hvac.pumHeaCoi.m_flow <= 1e5), hvac.pumHeaCoi.m_flow=-2.553405417806216e-14) --> "Variable violating min/max constraint: 0.0 <= hvac.pumHeaCoi.m_flow <= 1e5, has value: -2.55341e-14" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 7625100.000000 | | | | ((hvac.conVAV[5].ala.not1.y), hvac.conVAV[5].ala.not1.y=false) --> "Warning: airflow is less than 50% of the setpoint." LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 4.9924e-05s [ 0.0%] pre-initialization | | | | | | 5.50779s [ 10.5%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 2.13604s [ 4.1%] solver (excl. callbacks) | | | | | | 0.0878544s [ 0.2%] creating output-file | | | | | | 4.26386s [ 8.1%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 40.4493s [ 77.1%] simulation | | | | | | 52.4449s [100.0%] total | | | | | events | | | | | | 1235 state events | | | | | | 3865 time events | | | | | solver: dassl | | | | | | 107264 steps taken | | | | | | 145141 calls of functionODE | | | | | | 68553 evaluations of jacobian | | | | | | 2721 error test failures | | | | | | 321 convergence test failures | | | | | | 36.7644s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing final SQL reports EnergyPlus Run Time=00hr 00min 47.19sec EnergyPlus Completed Successfully.