startTime=0 stopTime=86400 tolerance=1e-08 numberOfIntervals=2500 stepSize=34.56 wasm-jit simulation: simulate(AixLib.Fluid.HeatPumps.ModularReversible.Examples.AirToWater2D_OneRoomRadiator,startTime=0,stopTime=86400,tolerance=1e-08,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="AixLib_AixLib.Fluid.HeatPumps.ModularReversible.Examples.AirToWater2D_OneRoomRadiator",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS") LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 3.0567e-05s [ 0.0%] pre-initialization | | | | | | 0.0254277s [ 18.9%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0.00829075s [ 6.2%] solver (excl. callbacks) | | | | | | 1.944e-06s [ 0.0%] creating output-file | | | | | | 0.0327024s [ 24.3%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 0.0682612s [ 50.7%] simulation | | | | | | 0.134715s [100.0%] total | | | | | events | | | | | | 49 state events | | | | | | 4 time events | | | | | solver: dassl | | | | | | 6063 steps taken | | | | | | 7400 calls of functionODE | | | | | | 1127 evaluations of jacobian | | | | | | 117 error test failures | | | | | | 0 convergence test failures | | | | | | 0.0277488s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.