Environment - simulationEnvironment: publicData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ privateData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ superstructureTables = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/superstructure/Tables/ superstructureInput = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/superstructure/RegionInformation/ startTime=0 stopTime=20000 tolerance=1e-06 numberOfIntervals=22 stepSize=909.091 Regular simulation: ./TransiEnt_TransiEnt.Producer.Electrical.Conventional.Components.Check.CheckSecondOrderPlant_VDIVDE3507 -abortSlowSimulation -alarm=240 -lv LOG_STATS LOG_STDOUT | warning | The nominal value of simCenter.rh_amb is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables//ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0136425s reading init.xml | | | | | | 0.00122459s reading info.xml | | | | | | 9.6722e-05s [ 0.4%] pre-initialization | | | | | | 0.0237341s [ 96.3%] initialization | | | | | | 2.806e-06s [ 0.0%] steps | | | | | | 0.000305553s [ 1.2%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 4.2501e-05s [ 0.2%] event-handling | | | | | | 9.0266e-05s [ 0.4%] overhead | | | | | | 0.00036557s [ 1.5%] simulation | | | | | | 0.0246375s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 2 time events | | | | | solver: dassl | | | | | | 347 steps taken | | | | | | 425 calls of functionODE | | | | | | 93 evaluations of jacobian | | | | | | 5 error test failures | | | | | | 0 convergence test failures | | | | | | 6.1195e-05s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.