Environment - simulationEnvironment: publicData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ privateData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ superstructureTables = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/superstructure/Tables/ superstructureInput = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/superstructure/RegionInformation/ startTime=0 stopTime=18000 tolerance=1e-06 numberOfIntervals=300 stepSize=60 Regular simulation: ./TransiEnt_TransiEnt.Consumer.Systems.FridgePoolControl.Pool.mainExplicitFridgePool -abortSlowSimulation -alarm=240 -lv LOG_STATS LOG_STDOUT | warning | The nominal value of pool.simCenter.rh_amb is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/electricity/FridgePool/fridgePool_N100.mat LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/electricity/FridgePool/fridgePool_N100.mat LOG_STDOUT | info | ... loading "A" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/electricity/FridgePool/fridgePool_N100.mat" LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables//ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0783614s reading init.xml | | | | | | 0.00789694s reading info.xml | | | | | | 0.000177273s [ 0.0%] pre-initialization | | | | | | 0.0270268s [ 0.5%] initialization | | | | | | 0.0184793s [ 0.3%] steps | | | | | | 4.662s [ 78.2%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.0135798s [ 0.2%] event-handling | | | | | | 0.000885788s [ 0.0%] overhead | | | | | | 1.24101s [ 20.8%] simulation | | | | | | 5.96316s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 4 time events | | | | | solver: dassl | | | | | | 191717 steps taken | | | | | | 370542 calls of functionODE | | | | | | 36887 evaluations of jacobian | | | | | | 17947 error test failures | | | | | | 1 convergence test failures | | | | | | 0.303471s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.