Environment - simulationEnvironment: startTime=0 stopTime=10000 tolerance=1e-06 numberOfIntervals=1000 stepSize=10 Regular simulation: ./ThermofluidStream_ThermofluidStream.Processes.Tests.CentrifugalPump -abortSlowSimulation -alarm=240 -emit_protected -ignoreHideResult -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00660079s reading init.xml | | | | | | 0.000574731s reading info.xml | | | | | | 0.00791579s [ 41.7%] pre-initialization | | | | | | 0.000677513s [ 3.6%] initialization | | | | | | 1.7793e-05s [ 0.1%] steps | | | | | | 0.000970345s [ 5.1%] solver (excl. callbacks) | | | | | | 0.000632516s [ 3.3%] creating output-file | | | | | | 0.000198384s [ 1.0%] event-handling | | | | | | 0.000702077s [ 3.7%] overhead | | | | | | 0.0078727s [ 41.5%] simulation | | | | | | 0.0189871s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 7 time events | | | | | solver: dassl | | | | | | 1040 steps taken | | | | | | 1449 calls of functionODE | | | | | | 134 evaluations of jacobian | | | | | | 11 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00197913s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.