Environment - simulationEnvironment: startTime=0 stopTime=200 tolerance=1e-06 numberOfIntervals=1000 stepSize=0.2 Regular simulation: ./ThermofluidStream_ThermofluidStream.Examples.ReverseHeatPump -abortSlowSimulation -alarm=690 -emit_protected -ignoreHideResult -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1/Boundaries/PhaseSeparator.mo:41:3-41:139:writable] | | | | The following assertion has been violated at time 1.000000 | | | | ((accumulator.x >= 0.0 and accumulator.x <= 1.0), accumulator.x=1.286648016763773) --> "Variable violating min/max constraint: 0.0 <= accumulator.x <= 1.0, has value: 1.28665" LOG_ASSERT | debug | Solving non-linear system 2665 failed at time=12.2625095923496. | | | | For more information please use -lv LOG_NLS. LOG_ASSERT | debug | Solving non-linear system 2665 failed at time=12.2625095923496. | | | | For more information please use -lv LOG_NLS. LOG_STDOUT | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 12.165253. That might raise performance issues, for more information use -lv LOG_LS. LOG_ASSERT | debug | Solving non-linear system 2718 failed at time=12.0193681183887. | | | | For more information please use -lv LOG_NLS. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1/FlowControl/Internal/PartialValve.mo:33:3-33:137:writable] | | | | The following assertion has been violated at time 77.200000 | | | | ((firstOrder.y <= 1.0 and firstOrder.y >= 0.0), firstOrder.y=-5.153421969701053e-12) --> "In "ReverseHeatPump.valveCompressorOutletCooling": Actuator signal out of valid range [0,1]" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1/FlowControl/Internal/PartialValve.mo:33:3-33:137:writable] | | | | The following assertion has been violated at time 77.200000 | | | | ((firstOrder.y <= 1.0 and firstOrder.y >= 0.0), firstOrder.y=-5.153421969701053e-12) --> "In "ReverseHeatPump.valveCompressorOutletHeating": Actuator signal out of valid range [0,1]" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1/FlowControl/Internal/PartialValve.mo:33:3-33:137:writable] | | | | The following assertion has been violated at time 77.200000 | | | | ((firstOrder.y <= 1.0 and firstOrder.y >= 0.0), firstOrder.y=-5.153421969701053e-12) --> "In "ReverseHeatPump.valveCompressorInletHeating": Actuator signal out of valid range [0,1]" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1/FlowControl/Internal/PartialValve.mo:33:3-33:137:writable] | | | | The following assertion has been violated at time 77.200000 | | | | ((firstOrder.y <= 1.0 and firstOrder.y >= 0.0), firstOrder.y=-5.153421969701053e-12) --> "In "ReverseHeatPump.valveCompressorInletCooling": Actuator signal out of valid range [0,1]" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0361542s reading init.xml | | | | | | 0.00363845s reading info.xml | | | | | | 0.000625135s [ 0.0%] pre-initialization | | | | | | 0.0110726s [ 0.0%] initialization | | | | | | 0.00219946s [ 0.0%] steps | | | | | | 0.0164925s [ 0.0%] solver (excl. callbacks) | | | | | | 0.000920956s [ 0.0%] creating output-file | | | | | | 6.95828s [ 16.2%] event-handling | | | | | | 0.00395895s [ 0.0%] overhead | | | | | | 36.0387s [ 83.7%] simulation | | | | | | 43.0323s [100.0%] total | | | | | events | | | | | | 6 state events | | | | | | 1 time events | | | | | solver: dassl | | | | | | 3550 steps taken | | | | | | 5560 calls of functionODE | | | | | | 612 evaluations of jacobian | | | | | | 317 error test failures | | | | | | 7 convergence test failures | | | | | | 24.957s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.