Environment - simulationEnvironment: startTime=0 stopTime=1000 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.4 Regular simulation: ./ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump -abortSlowSimulation -alarm=240 -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Machines/StaticCentrifugalPump.mo:21:3-21:45:writable] | | | | The following assertion has been violated at time 700.000000 | | | | ((StaticCentrifugalPump1.hn >= 0.0), StaticCentrifugalPump1.hn=-1.787758959822292e-25) --> "Variable violating min constraint: 0.0 <= StaticCentrifugalPump1.hn, has value: -1.78776e-25" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00201126s reading init.xml | | | | | | 0.000219262s reading info.xml | | | | | | 5.5124e-05s [ 0.2%] pre-initialization | | | | | | 0.000167094s [ 0.6%] initialization | | | | | | 7.447e-05s [ 0.2%] steps | | | | | | 0.000476424s [ 1.6%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.0151022s [ 50.1%] event-handling | | | | | | 0.00312719s [ 10.4%] overhead | | | | | | 0.011121s [ 36.9%] simulation | | | | | | 0.0301235s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 5 time events | | | | | solver: dassl | | | | | | 78 steps taken | | | | | | 78 calls of functionODE | | | | | | 72 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00286885s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.