Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermoSysPro_ThermoSysPro.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.Islanding.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/package.mo): time 0.4871/0.4871, allocations: 111.7 MB / 121.5 MB, free: 4.801 MB / 122.7 MB Notification: Performance of NFInstanceAPI.mkTop(): time 0.09677/0.5838, allocations: 33.97 MB / 155.5 MB, free: 3.727 MB / 154.7 MB " [Timeout remaining time 179] Using package ThermoSysPro with version 4.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/package.mo) Running command: translateModel(ThermoSysPro.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.Islanding,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.Islanding") translateModel(ThermoSysPro.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.Islanding,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.Islanding") [Timeout 660] "Notification: Performance of FrontEnd - loaded program: time 1.693e-06/1.693e-06, allocations: 0 / 156.7 MB, free: 2.551 MB / 154.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 2.098e-05/2.267e-05, allocations: 6.25 kB / 156.7 MB, free: 2.543 MB / 154.7 MB Notification: Automatically loaded package Complex 4.1.0 due to uses annotation from Modelica. Notification: Automatically loaded package ModelicaServices 4.1.0 due to uses annotation from Modelica. Notification: Automatically loaded package Modelica 4.1.0 due to usage. Notification: Performance of NFInst.instantiate(ThermoSysPro.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.Islanding): time 1.251/1.251, allocations: 244.5 MB / 401.2 MB, free: 7.422 MB / 394.7 MB Notification: Performance of NFInst.instExpressions: time 0.3916/1.642, allocations: 186.9 MB / 0.5743 GB, free: 12.55 MB / 0.5105 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.002352/1.645, allocations: 44 kB / 0.5744 GB, free: 12.54 MB / 0.5105 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/BoundaryConditions/SourceP.mo:19:3-20:78:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/BoundaryConditions/SinkP.mo:19:3-20:80:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:24:3-25:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:26:3-27:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/TwoPhaseCavity.mo:122:3-123:78:writable] Warning: Connector Cv is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/TwoPhaseCavity.mo:124:3-125:82:writable] Warning: Connector Cl is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/TwoPhaseCavity.mo:132:3-133:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicOnePhaseFlowPipe.mo:58:3-59:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicOnePhaseFlowPipe.mo:60:3-61:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicWaterHeating.mo:36:3-37:78:writable] Warning: Connector C1vap is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicWaterHeating.mo:38:3-39:80:writable] Warning: Connector C2ex is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicWaterHeating.mo:40:3-41:81:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicWaterHeating.mo:42:3-43:79:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicWaterHeating.mo:46:3-47:79:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicOnePhaseFlowPipe.mo:58:3-59:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicOnePhaseFlowPipe.mo:60:3-61:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicOnePhaseFlowPipe.mo:58:3-59:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicOnePhaseFlowPipe.mo:60:3-61:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:20:3-21:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:22:3-23:78:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:24:3-25:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:26:3-27:80:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeD.mo:20:3-21:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeD.mo:22:3-23:78:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeD.mo:24:3-25:80:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeD.mo:26:3-27:78:writable] Warning: Connector Cs3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeD.mo:20:3-21:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeD.mo:22:3-23:78:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeD.mo:24:3-25:80:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeD.mo:26:3-27:78:writable] Warning: Connector Cs3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/BoundaryConditions/Sink.mo:10:3-11:80:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:15:3-16:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:17:3-18:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:15:3-16:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:17:3-18:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/BoundaryConditions/SourceP.mo:19:3-20:78:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/BoundaryConditions/RefQ.mo:7:3-8:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/BoundaryConditions/RefQ.mo:9:3-10:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/IdealCheckValve.mo:12:3-13:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/IdealCheckValve.mo:14:3-15:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:15:3-16:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:17:3-18:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/LumpedStraightPipe.mo:29:3-30:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/LumpedStraightPipe.mo:31:3-32:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] Notification: Performance of NFTyping.typeComponents: time 0.001766/1.647, allocations: 0.9388 MB / 0.5753 GB, free: 12.24 MB / 0.5105 GB Notification: Performance of NFTyping.typeBindings: time 0.003796/1.65, allocations: 2.1 MB / 0.5773 GB, free: 11.63 MB / 0.5105 GB Notification: Performance of NFTyping.typeClassSections: time 0.02479/1.675, allocations: 12.38 MB / 0.5894 GB, free: 5.66 MB / 0.5105 GB Notification: Performance of NFFlatten.flatten: time 0.01839/1.694, allocations: 27.5 MB / 0.6163 GB, free: 3.27 MB / 0.5261 GB Notification: Performance of NFFlatten.resolveConnections: time 0.01173/1.705, allocations: 7.797 MB / 0.6239 GB, free: 11.71 MB / 0.5417 GB Notification: Performance of NFEvalConstants.evaluate: time 0.01848/1.724, allocations: 12.15 MB / 0.6358 GB, free: 15.9 MB / 0.5573 GB Notification: Performance of NFSimplifyModel.simplify: time 0.01134/1.735, allocations: 7.534 MB / 0.6431 GB, free: 8.793 MB / 0.5573 GB Notification: Performance of NFPackage.collectConstants: time 0.004911/1.74, allocations: 1.77 MB / 0.6448 GB, free: 7.023 MB / 0.5573 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/Properties/WaterSteam/IF97_packages.mo:470:9-470:27:writable] Warning: 'cv' is used uninitialized and may cause unexpected behaviour. This is deprecated and will become an error in future releases. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/Properties/WaterSteam/IF97_packages.mo:525:9-525:27:writable] Warning: 'cv' is used uninitialized and may cause unexpected behaviour. This is deprecated and will become an error in future releases. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/Properties/WaterSteam/IF97_packages.mo:708:9-708:27:writable] Warning: 'cv' is used uninitialized and may cause unexpected behaviour. This is deprecated and will become an error in future releases. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/Properties/WaterSteamSimple/prop4_Ph.mo:51:3-51:60:writable] Warning: 'dh1satp' is used uninitialized and may cause unexpected behaviour. This is deprecated and will become an error in future releases. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/Properties/WaterSteamSimple/prop4_Ph.mo:51:3-51:60:writable] Warning: 'dh2satp' is used uninitialized and may cause unexpected behaviour. This is deprecated and will become an error in future releases. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/Properties/WaterSteamSimple/prop4_Ph_der.mo:118:3-118:151:writable] Warning: 'du1satp_der' is used uninitialized and may cause unexpected behaviour. This is deprecated and will become an error in future releases. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/Properties/WaterSteamSimple/prop4_Ph_der.mo:118:3-118:151:writable] Warning: 'du2satp_der' is used uninitialized and may cause unexpected behaviour. This is deprecated and will become an error in future releases. Notification: Performance of NFFlatten.collectFunctions: time 0.03411/1.774, allocations: 22.99 MB / 0.6673 GB, free: 320 kB / 0.573 GB Notification: Performance of NFScalarize.scalarize: time 0.006437/1.781, allocations: 4.787 MB / 0.672 GB, free: 11.54 MB / 0.5886 GB Notification: Performance of NFVerifyModel.verify: time 0.01412/1.795, allocations: 4.934 MB / 0.6768 GB, free: 6.602 MB / 0.5886 GB Notification: Performance of NFConvertDAE.convert: time 0.04308/1.838, allocations: 23.53 MB / 0.6998 GB, free: 15.91 MB / 0.6198 GB Notification: Performance of FrontEnd - DAE generated: time 1.766e-05/1.838, allocations: 0 / 0.6998 GB, free: 15.91 MB / 0.6198 GB Notification: Performance of FrontEnd: time 1.723e-06/1.838, allocations: 0 / 0.6998 GB, free: 15.91 MB / 0.6198 GB Notification: Performance of Transformations before backend: time 0.0006117/1.838, allocations: 0 / 0.6998 GB, free: 15.91 MB / 0.6198 GB Error: Too few equations, under-determined system. The model has 3748 equation(s) and 3750 variable(s). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/InstrumentationAndControl/Connectors.mo:36:5-36:22:writable] Warning: Variable regulation_Niveau.MesureDebitEau.signal does not have any remaining equation to be solved in. The original equations were: [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/InstrumentationAndControl/Connectors.mo:36:5-36:22:writable] Warning: Variable regulation_Niveau.MesureDebitVapeur.signal does not have any remaining equation to be solved in. The original equations were: Notification: Performance of NFInstanceAPI.mkTop(): time 0.3815/2.22, allocations: 77.89 MB / 0.7758 GB, free: 116.1 MB / 0.6667 GB " [Timeout remaining time 658] [Calling sys.exit(0), Time elapsed: 3.115667467005551]