Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.ConcentratedSolarPowerPlant_PTSC.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/package.mo): time 0.4602/0.4602, allocations: 111.7 MB / 121.5 MB, free: 4.797 MB / 122.7 MB Notification: Performance of NFInstanceAPI.mkTop(): time 0.09064/0.5508, allocations: 33.97 MB / 155.5 MB, free: 3.727 MB / 154.7 MB " [Timeout remaining time 179] Using package ThermoSysPro with version 4.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/package.mo) Running command: translateModel(ThermoSysPro.Examples.Book.PowerPlants.ConcentratedSolarPowerPlant_PTSC,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.ConcentratedSolarPowerPlant_PTSC") translateModel(ThermoSysPro.Examples.Book.PowerPlants.ConcentratedSolarPowerPlant_PTSC,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.ConcentratedSolarPowerPlant_PTSC") [Timeout 660] "Notification: Performance of FrontEnd - loaded program: time 1.513e-06/1.513e-06, allocations: 0 / 156.7 MB, free: 2.543 MB / 154.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 1.748e-05/1.9e-05, allocations: 5.266 kB / 156.7 MB, free: 2.539 MB / 154.7 MB Notification: Automatically loaded package Complex 4.1.0 due to uses annotation from Modelica. Notification: Automatically loaded package ModelicaServices 4.1.0 due to uses annotation from Modelica. Notification: Automatically loaded package Modelica 4.1.0 due to usage. Notification: Performance of NFInst.instantiate(ThermoSysPro.Examples.Book.PowerPlants.ConcentratedSolarPowerPlant_PTSC): time 1.014/1.014, allocations: 256.6 MB / 413.3 MB, free: 11.29 MB / 410.7 MB Notification: Performance of NFInst.instExpressions: time 0.05479/1.068, allocations: 54.47 MB / 467.8 MB, free: 4.621 MB / 458.7 MB Notification: Performance of NFInst.updateImplicitVariability: time 0.003306/1.072, allocations: 55.81 kB / 467.9 MB, free: 4.566 MB / 458.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicOnePhaseFlowPipe.mo:58:3-59:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicOnePhaseFlowPipe.mo:60:3-61:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:15:3-16:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:17:3-18:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/Solar/HeatExchangers/DynamicOnePhaseFlowPipe_Oil.mo:50:3-51:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/Solar/HeatExchangers/DynamicOnePhaseFlowPipe_Oil.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:15:3-16:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:17:3-18:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/Solar/HeatExchangers/DynamicOnePhaseFlowPipe_Oil.mo:50:3-51:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/Solar/HeatExchangers/DynamicOnePhaseFlowPipe_Oil.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:90:3-91:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:94:3-95:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/Solar/HeatExchangers/DynamicOnePhaseFlowPipe_Oil.mo:50:3-51:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/Solar/HeatExchangers/DynamicOnePhaseFlowPipe_Oil.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Junctions/SteamDryer.mo:11:3-12:79:writable] Warning: Connector Cev is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Junctions/SteamDryer.mo:13:3-14:77:writable] Warning: Connector Csv is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Junctions/SteamDryer.mo:19:3-20:79:writable] Warning: Connector Csl is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/SimpleDynamicCondenser.mo:59:3-60:78:writable] Warning: Connector Cv is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/SimpleDynamicCondenser.mo:61:3-62:79:writable] Warning: Connector Cl is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/SimpleDynamicCondenser.mo:67:3-68:81:writable] Warning: Connector Cee is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/SimpleDynamicCondenser.mo:69:3-70:79:writable] Warning: Connector Cse is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/BoundaryConditions/SinkP.mo:19:3-20:80:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:15:3-16:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:17:3-18:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/InvSingularPressureLoss.mo:15:3-16:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/InvSingularPressureLoss.mo:17:3-18:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Machines/StaticCentrifugalPump.mo:33:3-34:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Machines/StaticCentrifugalPump.mo:35:3-36:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:20:3-21:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:22:3-23:78:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:24:3-25:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:26:3-27:80:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:24:3-25:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:26:3-27:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:24:3-25:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:26:3-27:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/BoundaryConditions/SourceP.mo:19:3-20:78:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:15:3-16:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:17:3-18:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:15:3-16:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:17:3-18:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Machines/StaticCentrifugalPump.mo:33:3-34:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Machines/StaticCentrifugalPump.mo:35:3-36:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:15:3-16:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:17:3-18:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Machines/StodolaTurbine.mo:36:3-37:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Machines/StodolaTurbine.mo:38:3-39:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Machines/StodolaTurbine.mo:42:3-43:99:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:90:3-91:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:94:3-95:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/Solar/HeatExchangers/DynamicOnePhaseFlowPipe_Oil.mo:50:3-51:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/Solar/HeatExchangers/DynamicOnePhaseFlowPipe_Oil.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Machines/StaticCentrifugalPump.mo:33:3-34:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Machines/StaticCentrifugalPump.mo:35:3-36:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:15:3-16:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:17:3-18:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:15:3-16:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:17:3-18:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Machines/StodolaTurbine.mo:36:3-37:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Machines/StodolaTurbine.mo:38:3-39:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Machines/StodolaTurbine.mo:42:3-43:99:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/Tank.mo:49:3-50:79:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/Tank.mo:51:3-52:79:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/Tank.mo:55:3-56:81:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/Tank.mo:57:3-58:77:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeA.mo:18:3-19:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeA.mo:20:3-21:78:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeA.mo:22:3-23:78:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeA.mo:26:3-27:80:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeA.mo:18:3-19:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeA.mo:20:3-21:78:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeA.mo:22:3-23:78:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeA.mo:26:3-27:80:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:38:3-39:80:writable] Warning: Connector Ee is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:40:3-41:78:writable] Warning: Connector Se is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:42:3-43:78:writable] Warning: Connector Ep is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:44:3-45:80:writable] Warning: Connector Sp is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:46:3-47:76:writable] Warning: Connector Ev is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:15:3-16:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:17:3-18:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/InvSingularPressureLoss.mo:15:3-16:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/InvSingularPressureLoss.mo:17:3-18:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:15:3-16:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:17:3-18:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Junctions/MassFlowMultiplier.mo:12:3-13:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Junctions/MassFlowMultiplier.mo:14:3-15:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Junctions/MassFlowMultiplier.mo:12:3-13:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Junctions/MassFlowMultiplier.mo:14:3-15:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [Non-standard Modelica: --allowNonStandardModelica=unbalancedModel] Notification: Performance of NFTyping.typeComponents: time 0.002477/1.074, allocations: 1.872 MB / 469.7 MB, free: 2.734 MB / 458.7 MB Notification: Performance of NFTyping.typeBindings: time 0.006493/1.081, allocations: 4.66 MB / 474.4 MB, free: 14.05 MB / 474.7 MB Notification: Performance of NFTyping.typeClassSections: time 0.02597/1.107, allocations: 15.16 MB / 489.6 MB, free: 14.82 MB / 490.7 MB Notification: Performance of NFFlatten.flatten: time 0.2199/1.326, allocations: 63.41 MB / 0.54 GB, free: 12.02 MB / 0.4948 GB Notification: Performance of NFFlatten.resolveConnections: time 0.02346/1.35, allocations: 21.53 MB / 0.561 GB, free: 6.305 MB / 0.4948 GB Notification: Performance of NFEvalConstants.evaluate: time 0.04541/1.395, allocations: 28.34 MB / 0.5887 GB, free: 10.04 MB / 0.5105 GB Notification: Performance of NFSimplifyModel.simplify: time 0.02989/1.425, allocations: 21.29 MB / 0.6095 GB, free: 9.109 MB / 0.5261 GB Notification: Performance of NFPackage.collectConstants: time 0.01116/1.436, allocations: 3.738 MB / 0.6132 GB, free: 5.371 MB / 0.5261 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/Properties/WaterSteam/IF97_packages.mo:470:9-470:27:writable] Warning: 'cv' is used uninitialized and may cause unexpected behaviour. This is deprecated and will become an error in future releases. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/Properties/WaterSteam/IF97_packages.mo:525:9-525:27:writable] Warning: 'cv' is used uninitialized and may cause unexpected behaviour. This is deprecated and will become an error in future releases. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/Properties/WaterSteam/IF97_packages.mo:708:9-708:27:writable] Warning: 'cv' is used uninitialized and may cause unexpected behaviour. This is deprecated and will become an error in future releases. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/Properties/WaterSteamSimple/prop4_Ph.mo:51:3-51:60:writable] Warning: 'dh1satp' is used uninitialized and may cause unexpected behaviour. This is deprecated and will become an error in future releases. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/Properties/WaterSteamSimple/prop4_Ph.mo:51:3-51:60:writable] Warning: 'dh2satp' is used uninitialized and may cause unexpected behaviour. This is deprecated and will become an error in future releases. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/Properties/WaterSteamSimple/prop4_Ph_der.mo:118:3-118:151:writable] Warning: 'du1satp_der' is used uninitialized and may cause unexpected behaviour. This is deprecated and will become an error in future releases. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/Properties/WaterSteamSimple/prop4_Ph_der.mo:118:3-118:151:writable] Warning: 'du2satp_der' is used uninitialized and may cause unexpected behaviour. This is deprecated and will become an error in future releases. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/Properties/WaterSteam/IF97_packages.mo:964:9-964:35:writable] Warning: 'h' is used uninitialized and may cause unexpected behaviour. This is deprecated and will become an error in future releases. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/Properties/WaterSteamSimple/prop4_Ps.mo:51:3-51:60:writable] Warning: 'dh1satp' is used uninitialized and may cause unexpected behaviour. This is deprecated and will become an error in future releases. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/Properties/WaterSteamSimple/prop4_Ps.mo:51:3-51:60:writable] Warning: 'dh2satp' is used uninitialized and may cause unexpected behaviour. This is deprecated and will become an error in future releases. Notification: Performance of NFFlatten.collectFunctions: time 0.04136/1.478, allocations: 26.81 MB / 0.6393 GB, free: 10.99 MB / 0.5573 GB Notification: Performance of NFScalarize.scalarize: time 0.01569/1.493, allocations: 13.15 MB / 0.6522 GB, free: 13.89 MB / 0.573 GB Notification: Performance of NFVerifyModel.verify: time 0.02588/1.519, allocations: 11.69 MB / 0.6636 GB, free: 2.176 MB / 0.573 GB Notification: Performance of NFConvertDAE.convert: time 0.06134/1.581, allocations: 44.65 MB / 0.7072 GB, free: 7.461 MB / 0.6198 GB Notification: Performance of FrontEnd - DAE generated: time 1.572e-05/1.581, allocations: 0 / 0.7072 GB, free: 7.461 MB / 0.6198 GB Notification: Performance of FrontEnd: time 2.214e-06/1.581, allocations: 0 / 0.7072 GB, free: 7.461 MB / 0.6198 GB Notification: Performance of Transformations before backend: time 0.00155/1.582, allocations: 0 / 0.7072 GB, free: 7.461 MB / 0.6198 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 8895 * Number of variables: 8895 Notification: Performance of Generate backend data structure: time 0.4274/2.01, allocations: 48.02 MB / 0.7541 GB, free: 168.7 MB / 0.6512 GB Notification: Performance of prepare preOptimizeDAE: time 3.42e-05/2.01, allocations: 11.02 kB / 0.7541 GB, free: 168.7 MB / 0.6512 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.02801/2.038, allocations: 8.781 MB / 0.7627 GB, free: 168.7 MB / 0.6512 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.01726/2.055, allocations: 8.546 MB / 0.771 GB, free: 167.1 MB / 0.6512 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.005429/2.06, allocations: 14.95 MB / 0.7856 GB, free: 152.8 MB / 0.6512 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.007714/2.068, allocations: 2.895 MB / 0.7885 GB, free: 152 MB / 0.6512 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.0448/2.113, allocations: 29.91 MB / 0.8177 GB, free: 145.1 MB / 0.6512 GB Notification: Performance of preOpt findStateOrder (simulation): time 0.0003366/2.113, allocations: 16.28 kB / 0.8177 GB, free: 145.1 MB / 0.6512 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.002361/2.116, allocations: 1.099 MB / 0.8188 GB, free: 144.3 MB / 0.6512 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 0.0003934/2.116, allocations: 0.9539 MB / 0.8197 GB, free: 144 MB / 0.6512 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.02214/2.138, allocations: 16.34 MB / 0.8357 GB, free: 135.3 MB / 0.6512 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.1406/2.279, allocations: 85.29 MB / 0.9189 GB, free: 53.61 MB / 0.6512 GB Notification: Performance of preOpt comSubExp (simulation): time 0.06412/2.343, allocations: 41.42 MB / 0.9594 GB, free: 11.82 MB / 0.6512 GB Notification: Performance of preOpt resolveLoops (simulation): time 0.02187/2.365, allocations: 9.638 MB / 0.9688 GB, free: 2.25 MB / 0.6512 GB Notification: Performance of preOpt evalFunc (simulation): time 0.3439/2.708, allocations: 92.06 MB / 1.059 GB, free: 181.8 MB / 0.6824 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.0006751/2.709, allocations: 497.1 kB / 1.059 GB, free: 181.7 MB / 0.6824 GB Notification: Performance of pre-optimization done (n=6261): time 7.058e-05/2.709, allocations: 0 / 1.059 GB, free: 181.7 MB / 0.6824 GB Notification: Performance of matching and sorting (n=6262): time 0.299/3.008, allocations: 118.6 MB / 1.175 GB, free: 81.41 MB / 0.6824 GB Notification: Performance of inlineWhenForInitialization (initialization): time 0.0002074/3.008, allocations: 0.5019 MB / 1.176 GB, free: 80.9 MB / 0.6824 GB Notification: Performance of selectInitializationVariablesDAE (initialization): time 0.00285/3.011, allocations: 4.114 MB / 1.18 GB, free: 77.76 MB / 0.6824 GB Notification: Performance of collectPreVariables (initialization): time 0.005971/3.017, allocations: 0.7664 MB / 1.18 GB, free: 77.58 MB / 0.6824 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Machines/StaticCentrifugalPump.mo:14:3-14:94:writable] Warning: The parameter Pompe.a1 has fixed = false and a binding equation Pompe.a1 = -4.9345734425e8, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/BoundaryConditions/SourceP.mo:4:3-4:68:writable] Warning: The parameter sourcePCaloporteur.P0 has fixed = false and a binding equation sourcePCaloporteur.P0 = 5e5, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Machines/StaticCentrifugalPump.mo:14:3-14:94:writable] Warning: The parameter Pompe1.a1 has fixed = false and a binding equation Pompe1.a1 = -9.5e8, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Machines/StodolaTurbine.mo:4:3-4:60:writable] Warning: The parameter Turbine.Cst has fixed = false and a binding equation Turbine.Cst = 6.19323e6, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Machines/StaticCentrifugalPump.mo:14:3-14:94:writable] Warning: The parameter Pompe2.a1 has fixed = false and a binding equation Pompe2.a1 = -1e8, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Machines/StodolaTurbine.mo:4:3-4:60:writable] Warning: The parameter TurbineMp.Cst has fixed = false and a binding equation TurbineMp.Cst = 6.19323e6, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:5:3-5:96:writable] Warning: The parameter Re_1.SCondDes has fixed = false and a binding equation Re_1.SCondDes = 3.0, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. Notification: Performance of collectInitialEqns (initialization): time 0.001271/3.018, allocations: 4.712 MB / 1.185 GB, free: 73.49 MB / 0.6824 GB Notification: Performance of collectInitialBindings (initialization): time 0.01249/3.031, allocations: 22.74 MB / 1.207 GB, free: 53.06 MB / 0.6824 GB Notification: Performance of simplifyInitialFunctions (initialization): time 0.008482/3.039, allocations: 7.813 MB / 1.215 GB, free: 46.38 MB / 0.6824 GB Notification: Performance of setup shared object (initialization): time 2.045e-05/3.039, allocations: 301.1 kB / 1.215 GB, free: 46.08 MB / 0.6824 GB Notification: Performance of preBalanceInitialSystem (initialization): time 0.01025/3.05, allocations: 7.797 MB / 1.223 GB, free: 38.27 MB / 0.6824 GB Notification: Performance of partitionIndependentBlocks (initialization): time 0.01206/3.062, allocations: 12.45 MB / 1.235 GB, free: 25.88 MB / 0.6824 GB Notification: It was not possible to check the given initialization system for consistency symbolically, because the relevant equations are part of an algebraic loop. This is not supported yet. Notification: Performance of analyzeInitialSystem (initialization): time 0.3006/3.362, allocations: 61.47 MB / 1.295 GB, free: 149.2 MB / 0.6824 GB Notification: Performance of solveInitialSystemEqSystem (initialization): time 0.0001172/3.363, allocations: 25.03 kB / 1.295 GB, free: 149.2 MB / 0.6824 GB Notification: Performance of matching and sorting (n=6996) (initialization): time 0.09209/3.455, allocations: 36.49 MB / 1.33 GB, free: 139.5 MB / 0.6824 GB Notification: Performance of prepare postOptimizeDAE: time 9.548e-05/3.455, allocations: 36 kB / 1.33 GB, free: 139.5 MB / 0.6824 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 0.0002229/3.455, allocations: 104.2 kB / 1.331 GB, free: 139.4 MB / 0.6824 GB Notification: Performance of postOpt tearingSystem (initialization): time 0.8566/4.312, allocations: 358 MB / 1.68 GB, free: 42.88 MB / 0.7137 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.003171/4.315, allocations: 1.481 MB / 1.682 GB, free: 41.74 MB / 0.7137 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.08951/4.404, allocations: 48.96 MB / 1.729 GB, free: 8.793 MB / 0.7137 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.03145/4.436, allocations: 1.781 MB / 1.731 GB, free: 7.992 MB / 0.7137 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.009344/4.445, allocations: 1.362 MB / 1.733 GB, free: 7.402 MB / 0.7137 GB Warning: The initial conditions are over specified. The following 7 initial equations are redundant, so they are removed from the initialization system: $DER.VolumeMP.P = 0.0 VolumeMP.P = $START.VolumeMP.P PerteCharge_Huile_2.Q = $START.PerteCharge_Huile_2.Q PerteChargeCondPompe3.C2.P = $START.PerteChargeCondPompe3.C2.P ControlValveBallon.h = $START.ControlValveBallon.h ControlValveBallon.Q = $START.ControlValveBallon.Q TubeEcran_2.P[7] = $START.TubeEcran_2.P[7]. Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 353 * Number of states: 0 () * Number of discrete variables: 92 (Ballon.Ce3.b,Tank.Ce1.b,Tank.Cs1.a,VolumeMP.Ce2.b,VolumeCond.Cs1.a,Re_1.Ep.b,TubeEcran_2.C1.a,TubeEcran_2.C2.b,PerteCharge_Huile_3.C1.a,PerteCharge_Huile_3.C2.b,TubeEcran_3.C1.a,TubeEcran_3.C2.b,PerteCharge_Huile_4.C1.a,PerteCharge_Huile_4.C2.b,TubeEcran_22.C1.a,TubeEcran_22.C2.b,TubeEcran_1.C1.a,TubeEcran_1.C2.b,TubeEcran_11.C1.a,TubeEcran_11.C2.b,Secheur.Cev.a,Secheur.Csv.b,Secheur.Csl.b,Condenseur.Cv.a,Condenseur.Cl.b,Condenseur.Cee.a,Condenseur.Cse.b,puitsPCaloporteur.C.a,PerteChargeCondPompe.C1.a,PerteChargeCondPompe.C2.b,Connection_HQ_Secheur_Ballon.C1.a,Connection_HQ_Secheur_Ballon.C2.b,Pompe.C1.a,Pompe.C2.b,Ballon.Ce1.a,Ballon.Ce2.a,Ballon.Cs.b,Ballon.Ce3.a,ControlValveBallon.C1.a,ControlValveBallon.C2.b,ControlValveBallon1.C1.a,ControlValveBallon1.C2.b,sourcePCaloporteur.C.b,PerteChargeCondPompe1.C1.a,PerteChargeCondPompe1.C2.b,PerteChargeCondPompe2.C1.a,PerteChargeCondPompe2.C2.b,Pompe1.C1.a,Pompe1.C2.b,PerteChargeCondPompe3.C1.a,PerteChargeCondPompe3.C2.b,Turbine.Ce.a,Turbine.Cs.b,TubeEcran_4.C1.a,TubeEcran_4.C2.b,TubeEcran_44.C1.a,TubeEcran_44.C2.b,Pompe2.C1.a,Pompe2.C2.b,PerteCharge_Huile_2.C1.a,PerteCharge_Huile_2.C2.b,PerteCharge_Huile_1.C1.a,PerteCharge_Huile_1.C2.b,TurbineMp.Ce.a,TurbineMp.Cs.b,Tank.Ce1.a,Tank.Cs2.b,Tank.Ce2.a,Tank.Cs1.b,VolumeMP.Ce1.a,VolumeMP.Ce2.a,VolumeMP.Cs1.b,VolumeMP.Cs2.b,VolumeCond.Ce1.a,VolumeCond.Ce2.a,VolumeCond.Cs1.b,VolumeCond.Cs2.b,Re_1.Ee.a,Re_1.Se.b,Re_1.Ep.a,Re_1.Sp.b,Re_1.Ev.a,Dp_Re_1.C1.a,Dp_Re_1.C2.b,invSingularPressureLoss.C1.a,invSingularPressureLoss.C2.b,Dp_Cond_2.C1.a,Dp_Cond_2.C2.b,massFlowMultiplier.Ce.a,massFlowMultiplier.Cs.b,massFlowMultiplier2.Ce.a,massFlowMultiplier2.Cs.b) * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (824): * Single equations (assignments): 793 * Array equations: 0 * Algorithm blocks: 0 * Record equations: 28 * When equations: 0 * If-equations: 0 * Equation systems (not torn): 0 * Torn equation systems: 3 * Mixed (continuous/discrete) equation systems: 0 Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 1 system {(4,1,62.5%)} * Non-linear torn systems (#iteration vars, #inner vars): 2 systems {(409,3969), (4,11)} Notification: Performance of prepare postOptimizeDAE: time 0.02063/4.466, allocations: 1.891 MB / 1.734 GB, free: 6.887 MB / 0.7137 GB Notification: Performance of postOpt lateInlineFunction (simulation): time 0.02054/4.486, allocations: 2.984 MB / 1.737 GB, free: 5.125 MB / 0.7137 GB Notification: Performance of postOpt wrapFunctionCalls (simulation): time 0.3738/4.86, allocations: 54 MB / 1.79 GB, free: 210.1 MB / 0.7449 GB Notification: Performance of postOpt inlineArrayEqn (simulation): time 0.1117/4.972, allocations: 39.27 MB / 1.828 GB, free: 205.6 MB / 0.7449 GB Notification: Performance of postOpt constantLinearSystem (simulation): time 0.0002594/4.972, allocations: 35.59 kB / 1.828 GB, free: 205.6 MB / 0.7449 GB Notification: Performance of postOpt simplifysemiLinear (simulation): time 0.001104/4.973, allocations: 263.9 kB / 1.829 GB, free: 205.6 MB / 0.7449 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of postOpt removeSimpleEquations (simulation): time 0.2357/5.209, allocations: 84.07 MB / 1.911 GB, free: 185 MB / 0.7449 GB Notification: Performance of postOpt simplifyComplexFunction (simulation): time 0.0005233/5.209, allocations: 31.97 kB / 1.911 GB, free: 185 MB / 0.7449 GB Notification: Performance of postOpt solveSimpleEquations (simulation): time 0.034/5.243, allocations: 12.01 MB / 1.923 GB, free: 173.3 MB / 0.7449 GB Notification: Performance of postOpt removeConstants (simulation): time 0.02193/5.265, allocations: 6.016 MB / 1.928 GB, free: 167.4 MB / 0.7449 GB Notification: Performance of postOpt tearingSystem (simulation): time 0.1503/5.416, allocations: 67.8 MB / 1.995 GB, free: 98.81 MB / 0.7449 GB Notification: Performance of postOpt inputDerivativesUsed (simulation): time 0.0141/5.43, allocations: 1.451 MB / 1.996 GB, free: 97.36 MB / 0.7449 GB Notification: Performance of postOpt calculateStrongComponentJacobians (simulation): time 0.3594/5.789, allocations: 242 MB / 2.232 GB, free: 56.7 MB / 0.7449 GB Notification: Performance of postOpt calculateStateSetsJacobians (simulation): time 0.0001589/5.789, allocations: 3.969 kB / 2.232 GB, free: 56.7 MB / 0.7449 GB Notification: Performance of postOpt symbolicJacobian (simulation): time 0.1828/5.972, allocations: 67.08 MB / 2.298 GB, free: 50.73 MB / 0.7449 GB Notification: Performance of postOpt simplifyTimeIndepFuncCalls (simulation): time 0.01234/5.984, allocations: 1.052 MB / 2.299 GB, free: 50.73 MB / 0.7449 GB Notification: Performance of postOpt simplifyAllExpressions (simulation): time 0.02456/6.009, allocations: 1.762 MB / 2.301 GB, free: 50.73 MB / 0.7449 GB Notification: Performance of postOpt findZeroCrossings (simulation): time 0.01556/6.025, allocations: 3.596 MB / 2.304 GB, free: 50.69 MB / 0.7449 GB Notification: Performance of postOpt collapseArrayExpressions (simulation): time 0.01212/6.037, allocations: 1.26 MB / 2.305 GB, free: 50.52 MB / 0.7449 GB Notification: Performance of sorting global known variables: time 0.002373/6.039, allocations: 1.98 MB / 2.307 GB, free: 49.25 MB / 0.7449 GB Notification: Performance of sort global known variables: time 4.31e-07/6.039, allocations: 0 / 2.307 GB, free: 49.25 MB / 0.7449 GB Notification: Performance of remove unused functions: time 0.04506/6.084, allocations: 14.15 MB / 2.321 GB, free: 36.93 MB / 0.7449 GB Notification: Model statistics after passing the back-end for simulation: * Number of independent subsystems: 11 * Number of states: 363 (TubeEcran_2.P[2],TubeEcran_2.P[3],TubeEcran_2.P[4],TubeEcran_2.P[5],TubeEcran_2.P[6],TubeEcran_2.h[2],TubeEcran_2.h[3],TubeEcran_2.h[4],TubeEcran_2.h[5],TubeEcran_2.h[6],Paroi2.Tp[1],Paroi2.Tp[2],Paroi2.Tp[3],Paroi2.Tp[4],Paroi2.Tp[5],Paroi3.Tp[1],Paroi3.Tp[2],Paroi3.Tp[3],Paroi3.Tp[4],Paroi3.Tp[5],Paroi3.Tp[6],Paroi3.Tp[7],Paroi3.Tp[8],Paroi3.Tp[9],Paroi3.Tp[10],Paroi3.Tp[11],Paroi3.Tp[12],Paroi3.Tp[13],Paroi3.Tp[14],Paroi3.Tp[15],Paroi3.Tp[16],Paroi3.Tp[17],Paroi3.Tp[18],Paroi3.Tp[19],Paroi3.Tp[20],Paroi3.Tp[21],Paroi3.Tp[22],Paroi3.Tp[23],Paroi3.Tp[24],Paroi3.Tp[25],Paroi3.Tp[26],Paroi3.Tp[27],Paroi3.Tp[28],Paroi3.Tp[29],Paroi3.Tp[30],Paroi3.Tp[31],Paroi3.Tp[32],Paroi3.Tp[33],Paroi3.Tp[34],Paroi3.Tp[35],Paroi3.Tp[36],Paroi3.Tp[37],Paroi3.Tp[38],Paroi3.Tp[39],Paroi3.Tp[40],Paroi3.Tp[41],Paroi3.Tp[42],Paroi3.Tp[43],Paroi3.Tp[44],Paroi3.Tp[45],Paroi3.Tp[46],Paroi3.Tp[47],Paroi3.Tp[48],Paroi3.Tp[49],Paroi3.Tp[50],Paroi3.Tp[51],Paroi3.Tp[52],Paroi3.Tp[53],Paroi3.Tp[54],Paroi3.Tp[55],Paroi3.Tp[56],Paroi3.Tp[57],Paroi3.Tp[58],Paroi3.Tp[59],Paroi3.Tp[60],Paroi3.Tp[61],Paroi3.Tp[62],Paroi3.Tp[63],Paroi3.Tp[64],Paroi3.Tp[65],Paroi3.Tp[66],Paroi3.Tp[67],Paroi3.Tp[68],Paroi3.Tp[69],Paroi3.Tp[70],Paroi3.Tp[71],Paroi3.Tp[72],Paroi3.Tp[73],Paroi3.Tp[74],Paroi3.Tp[75],Paroi3.Tp[76],Paroi3.Tp[77],Paroi3.Tp[78],Paroi3.Tp[79],Paroi3.Tp[80],SolarCollector1.Tglass[1],SolarCollector1.Tglass[2],SolarCollector1.Tglass[3],SolarCollector1.Tglass[4],SolarCollector1.Tglass[5],SolarCollector1.Tglass[6],SolarCollector1.Tglass[7],SolarCollector1.Tglass[8],SolarCollector1.Tglass[9],SolarCollector1.Tglass[10],SolarCollector1.Tglass[11],SolarCollector1.Tglass[12],SolarCollector1.Tglass[13],SolarCollector1.Tglass[14],SolarCollector1.Tglass[15],SolarCollector1.Tglass[16],SolarCollector1.Tglass[17],SolarCollector1.Tglass[18],SolarCollector1.Tglass[19],SolarCollector1.Tglass[20],SolarCollector1.Tglass[21],SolarCollector1.Tglass[22],SolarCollector1.Tglass[23],SolarCollector1.Tglass[24],SolarCollector1.Tglass[25],SolarCollector1.Tglass[26],SolarCollector1.Tglass[27],SolarCollector1.Tglass[28],SolarCollector1.Tglass[29],SolarCollector1.Tglass[30],SolarCollector1.Tglass[31],SolarCollector1.Tglass[32],SolarCollector1.Tglass[33],SolarCollector1.Tglass[34],SolarCollector1.Tglass[35],SolarCollector1.Tglass[36],SolarCollector1.Tglass[37],SolarCollector1.Tglass[38],SolarCollector1.Tglass[39],SolarCollector1.Tglass[40],SolarCollector1.Tglass[41],SolarCollector1.Tglass[42],SolarCollector1.Tglass[43],SolarCollector1.Tglass[44],SolarCollector1.Tglass[45],SolarCollector1.Tglass[46],SolarCollector1.Tglass[47],SolarCollector1.Tglass[48],SolarCollector1.Tglass[49],SolarCollector1.Tglass[50],SolarCollector1.Tglass[51],SolarCollector1.Tglass[52],SolarCollector1.Tglass[53],SolarCollector1.Tglass[54],SolarCollector1.Tglass[55],SolarCollector1.Tglass[56],SolarCollector1.Tglass[57],SolarCollector1.Tglass[58],SolarCollector1.Tglass[59],SolarCollector1.Tglass[60],SolarCollector1.Tglass[61],SolarCollector1.Tglass[62],SolarCollector1.Tglass[63],SolarCollector1.Tglass[64],SolarCollector1.Tglass[65],SolarCollector1.Tglass[66],SolarCollector1.Tglass[67],SolarCollector1.Tglass[68],SolarCollector1.Tglass[69],SolarCollector1.Tglass[70],SolarCollector1.Tglass[71],SolarCollector1.Tglass[72],SolarCollector1.Tglass[73],SolarCollector1.Tglass[74],SolarCollector1.Tglass[75],SolarCollector1.Tglass[76],SolarCollector1.Tglass[77],SolarCollector1.Tglass[78],SolarCollector1.Tglass[79],SolarCollector1.Tglass[80],TubeEcran_3.h[2],TubeEcran_3.h[3],TubeEcran_3.h[4],TubeEcran_3.h[5],TubeEcran_3.h[6],TubeEcran_3.h[7],TubeEcran_3.h[8],TubeEcran_3.h[9],TubeEcran_3.h[10],TubeEcran_3.h[11],TubeEcran_3.h[12],TubeEcran_3.h[13],TubeEcran_3.h[14],TubeEcran_3.h[15],TubeEcran_3.h[16],TubeEcran_3.h[17],TubeEcran_3.h[18],TubeEcran_3.h[19],TubeEcran_3.h[20],TubeEcran_3.h[21],TubeEcran_3.h[22],TubeEcran_3.h[23],TubeEcran_3.h[24],TubeEcran_3.h[25],TubeEcran_3.h[26],TubeEcran_3.h[27],TubeEcran_3.h[28],TubeEcran_3.h[29],TubeEcran_3.h[30],TubeEcran_3.h[31],TubeEcran_3.h[32],TubeEcran_3.h[33],TubeEcran_3.h[34],TubeEcran_3.h[35],TubeEcran_3.h[36],TubeEcran_3.h[37],TubeEcran_3.h[38],TubeEcran_3.h[39],TubeEcran_3.h[40],TubeEcran_3.h[41],TubeEcran_3.h[42],TubeEcran_3.h[43],TubeEcran_3.h[44],TubeEcran_3.h[45],TubeEcran_3.h[46],TubeEcran_3.h[47],TubeEcran_3.h[48],TubeEcran_3.h[49],TubeEcran_3.h[50],TubeEcran_3.h[51],TubeEcran_3.h[52],TubeEcran_3.h[53],TubeEcran_3.h[54],TubeEcran_3.h[55],TubeEcran_3.h[56],TubeEcran_3.h[57],TubeEcran_3.h[58],TubeEcran_3.h[59],TubeEcran_3.h[60],TubeEcran_3.h[61],TubeEcran_3.h[62],TubeEcran_3.h[63],TubeEcran_3.h[64],TubeEcran_3.h[65],TubeEcran_3.h[66],TubeEcran_3.h[67],TubeEcran_3.h[68],TubeEcran_3.h[69],TubeEcran_3.h[70],TubeEcran_3.h[71],TubeEcran_3.h[72],TubeEcran_3.h[73],TubeEcran_3.h[74],TubeEcran_3.h[75],TubeEcran_3.h[76],TubeEcran_3.h[77],TubeEcran_3.h[78],TubeEcran_3.h[79],TubeEcran_3.h[80],TubeEcran_3.h[81],TubeEcran_22.h[2],TubeEcran_22.h[3],TubeEcran_22.h[4],TubeEcran_22.h[5],TubeEcran_22.h[6],Paroi1.Tp[1],Paroi1.Tp[2],Paroi1.Tp[3],Paroi1.Tp[4],Paroi1.Tp[5],Paroi1.Tp[6],Paroi1.Tp[7],Paroi1.Tp[8],Paroi1.Tp[9],Paroi1.Tp[10],Paroi1.Tp[11],Paroi1.Tp[12],Paroi1.Tp[13],Paroi1.Tp[14],Paroi1.Tp[15],Paroi1.Tp[16],Paroi1.Tp[17],Paroi1.Tp[18],Paroi1.Tp[19],Paroi1.Tp[20],TubeEcran_1.P[2],TubeEcran_1.P[3],TubeEcran_1.P[4],TubeEcran_1.P[5],TubeEcran_1.P[6],TubeEcran_1.P[7],TubeEcran_1.P[8],TubeEcran_1.P[9],TubeEcran_1.P[10],TubeEcran_1.P[11],TubeEcran_1.P[12],TubeEcran_1.P[13],TubeEcran_1.P[14],TubeEcran_1.P[15],TubeEcran_1.P[16],TubeEcran_1.P[17],TubeEcran_1.P[18],TubeEcran_1.P[19],TubeEcran_1.P[20],TubeEcran_1.P[21],TubeEcran_1.h[2],TubeEcran_1.h[3],TubeEcran_1.h[4],TubeEcran_1.h[5],TubeEcran_1.h[6],TubeEcran_1.h[7],TubeEcran_1.h[8],TubeEcran_1.h[9],TubeEcran_1.h[10],TubeEcran_1.h[11],TubeEcran_1.h[12],TubeEcran_1.h[13],TubeEcran_1.h[14],TubeEcran_1.h[15],TubeEcran_1.h[16],TubeEcran_1.h[17],TubeEcran_1.h[18],TubeEcran_1.h[19],TubeEcran_1.h[20],TubeEcran_1.h[21],TubeEcran_11.h[2],TubeEcran_11.h[3],TubeEcran_11.h[4],TubeEcran_11.h[5],TubeEcran_11.h[6],TubeEcran_11.h[7],TubeEcran_11.h[8],TubeEcran_11.h[9],TubeEcran_11.h[10],TubeEcran_11.h[11],TubeEcran_11.h[12],TubeEcran_11.h[13],TubeEcran_11.h[14],TubeEcran_11.h[15],TubeEcran_11.h[16],TubeEcran_11.h[17],TubeEcran_11.h[18],TubeEcran_11.h[19],TubeEcran_11.h[20],TubeEcran_11.h[21],Condenseur.P,Condenseur.hl,Condenseur.hv,Condenseur.Vv,Ballon.P,Ballon.h,Paroi4.Tp[1],Paroi4.Tp[2],Paroi4.Tp[3],TubeEcran_4.P[2],TubeEcran_4.P[3],TubeEcran_4.P[4],TubeEcran_4.h[2],TubeEcran_4.h[3],TubeEcran_4.h[4],TubeEcran_44.h[2],TubeEcran_44.h[3],TubeEcran_44.h[4],Tank.z,Tank.h,VolumeMP.P,VolumeMP.h,VolumeCond.h) * Number of discrete variables: 0 () * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for simulation (3545): * Single equations (assignments): 3236 * Array equations: 0 * Algorithm blocks: 0 * Record equations: 105 * When equations: 0 * If-equations: 0 * Equation systems (not torn): 2 * Torn equation systems: 202 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 2 systems {(2,100.0%), (2,100.0%)} * Non-linear Jacobian (size): 0 systems * Without analytic Jacobian (size): 0 systems Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 142 systems {(1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (4,1,62.5%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%)} * Non-linear torn systems (#iteration vars, #inner vars): 60 systems {(1,6), (1,6), (1,15), (1,6), (1,15), (1,6), (1,15), (1,6), (1,15), (1,6), (1,15), (1,6), (1,15), (1,6), (1,15), (1,6), (1,15), (1,6), (1,15), (1,6), (1,15), (1,6), (1,15), (1,6), (1,15), (1,6), (1,15), (1,6), (1,15), (1,6), (1,15), (1,6), (1,15), (1,6), (1,15), (1,6), (1,15), (1,6), (1,15), (5,28), (1,6), (1,6), (1,15), (1,6), (1,15), (3,33), (1,2), (1,2), (5,13), (1,7), (10,1140), (19,43), (8,34), (1,2), (1,2), (2,9), (1,8), (1,8), (1,8), (1,8)} Notification: Performance of Backend phase and start with SimCode phase: time 0.01736/6.101, allocations: 4.601 MB / 2.326 GB, free: 34.35 MB / 0.7449 GB Notification: Performance of simCode: created initialization part: time 0.3418/6.443, allocations: 59.16 MB / 2.383 GB, free: 157 MB / 0.7449 GB Notification: Performance of simCode: created event and clocks part: time 0.0007477/6.444, allocations: 276.6 kB / 2.384 GB, free: 156.9 MB / 0.7449 GB Notification: Performance of simCode: created simulation system equations: time 0.08623/6.53, allocations: 44.75 MB / 2.427 GB, free: 136.2 MB / 0.7449 GB Notification: Performance of simCode: created of all other equations (e.g. parameter, nominal, assert, etc): time 0.0621/6.592, allocations: 14.96 MB / 2.442 GB, free: 134.9 MB / 0.7449 GB Notification: Performance of simCode: created linear, non-linear and system jacobian parts: time 0.4185/7.011, allocations: 77.83 MB / 2.518 GB, free: 103.6 MB / 0.7449 GB Notification: Performance of simCode: some other stuff during SimCode phase: time 0.0145/7.025, allocations: 8.052 MB / 2.526 GB, free: 97.97 MB / 0.7449 GB Notification: Performance of simCode: alias equations: time 0.02152/7.047, allocations: 3.075 MB / 2.529 GB, free: 95.33 MB / 0.7449 GB Notification: Performance of simCode: all other stuff during SimCode phase: time 0.04276/7.09, allocations: 7.184 MB / 2.536 GB, free: 89.98 MB / 0.7449 GB Notification: Performance of SimCode: time 1.974e-06/7.09, allocations: 9.859 kB / 2.536 GB, free: 89.97 MB / 0.7449 GB Notification: Performance of Templates: time 2.569/9.658, allocations: 1.198 GB / 3.734 GB, free: 60.15 MB / 0.8078 GB Notification: Performance of NFInstanceAPI.mkTop(): time 0.07115/9.73, allocations: 53.73 MB / 3.787 GB, free: 24.54 MB / 0.8078 GB " [Timeout remaining time 650] make -j1 -f ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.ConcentratedSolarPowerPlant_PTSC.makefile [Timeout 660] (rm -f ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.ConcentratedSolarPowerPlant_PTSC.pipe ; mkfifo ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.ConcentratedSolarPowerPlant_PTSC.pipe ; head -c 1048576 < ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.ConcentratedSolarPowerPlant_PTSC.pipe >> ../files/ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.ConcentratedSolarPowerPlant_PTSC.sim & ./ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.ConcentratedSolarPowerPlant_PTSC -abortSlowSimulation -alarm=240 -lv LOG_STATS > ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.ConcentratedSolarPowerPlant_PTSC.pipe 2>&1) [Timeout 240] [Calling os._exit(0), Time elapsed: 59.19036769401282]