Environment - simulationEnvironment: startTime=0 stopTime=10 tolerance=1e-06 numberOfIntervals=500 stepSize=0.02 Regular simulation: ./PowerGrids_dev_PowerGrids.Examples.Tutorial.GridOperation.Controlled.ControlledGridParametersChange -abortSlowSimulation -alarm=240 -emit_protected -ignoreHideResult -lv LOG_STATS -s=ida LOG_STDOUT | warning | Internal Numerical Jacobians without coloring are currently not supported by IDA with KLU. Colored numerical Jacobian will be used. LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:34:5-34:161:writable] | | | | The following assertion has been violated at time 2.000000 | | | | ((GEN.VPuCheck > GEN.VPuMin), GEN.VPuCheck=0.4102500426868425, GEN.VPuMin=0.7) --> "Voltage too low (VPu=0.41025 < 0.7), check if the numerical solution is valid" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:35:5-35:162:writable] | | | | The following assertion has been violated at time 2.000000 | | | | ((GEN.IPuCheck < GEN.IPuMax), GEN.IPuCheck=2.565488808058341, GEN.IPuMax=2.5) --> "Current too high (IPu=2.56549 > 2.5), check if the numerical solution is valid" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:34:5-34:161:writable] | | | | The following assertion has been violated at time 2.000000 | | | | ((NTLV.VPuCheck > NTLV.VPuMin), NTLV.VPuCheck=0.4102500426868431, NTLV.VPuMin=0.7) --> "Voltage too low (VPu=0.41025 < 0.7), check if the numerical solution is valid" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:34:5-34:161:writable] | | | | The following assertion has been violated at time 2.000000 | | | | ((GRID.VPuCheck > GRID.VPuMin), GRID.VPuCheck=0.001211686852230993, GRID.VPuMin=0.7) --> "Voltage too low (VPu=0.00121169 < 0.7), check if the numerical solution is valid" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:35:5-35:162:writable] | | | | The following assertion has been violated at time 2.000000 | | | | ((GRID.IPuCheck < GRID.IPuMax), GRID.IPuCheck=4.769210782925525, GRID.IPuMax=2.5) --> "Current too high (IPu=4.76921 > 2.5), check if the numerical solution is valid" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:34:5-34:161:writable] | | | | The following assertion has been violated at time 2.000000 | | | | ((GRIDL.VPuCheck > GRIDL.VPuMin), GRIDL.VPuCheck=0.001211686852230993, GRIDL.VPuMin=0.7) --> "Voltage too low (VPu=0.00121169 < 0.7), check if the numerical solution is valid" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:34:5-34:161:writable] | | | | The following assertion has been violated at time 2.000000 | | | | ((FAULT.VPuCheck > FAULT.VPuMin), FAULT.VPuCheck=0.001211686852230993, FAULT.VPuMin=0.7) --> "Voltage too low (VPu=0.00121169 < 0.7), check if the numerical solution is valid" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:35:5-35:162:writable] | | | | The following assertion has been violated at time 2.000000 | | | | ((FAULT.IPuCheck < FAULT.IPuMax), FAULT.IPuCheck=6.998703258484412, FAULT.IPuMax=2.5) --> "Current too high (IPu=6.9987 > 2.5), check if the numerical solution is valid" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0196532s reading init.xml | | | | | | 0.00359931s reading info.xml | | | | | | 0.00552843s [ 30.4%] pre-initialization | | | | | | 0.00171236s [ 9.4%] initialization | | | | | | 2.184e-06s [ 0.0%] steps | | | | | | 0.00688571s [ 37.8%] solver (excl. callbacks) | | | | | | 0.000727312s [ 4.0%] creating output-file | | | | | | 0.00129887s [ 7.1%] event-handling | | | | | | 0.000884841s [ 4.9%] overhead | | | | | | 0.00116993s [ 6.4%] simulation | | | | | | 0.0182096s [100.0%] total | | | | | events | | | | | | 14 state events | | | | | | 2 time events | | | | | solver: ida | | | | | | 1024 steps taken | | | | | | 1422 calls of functionODE | | | | | | 232 evaluations of jacobian | | | | | | 36 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00363825s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.