Environment - simulationEnvironment: startTime=0 stopTime=0.1 tolerance=1e-06 numberOfIntervals=500 stepSize=0.0002 Regular simulation: ./Modelica_4.0.0_Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierBridge2mPulse.ThyristorBridge2mPulse_RL -abortSlowSimulation -alarm=240 -emit_protected -ignoreHideResult -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00480238s reading init.xml | | | | | | 0.000573598s reading info.xml | | | | | | 0.000229211s [ 1.1%] pre-initialization | | | | | | 0.000402546s [ 1.9%] initialization | | | | | | 2.0358e-05s [ 0.1%] steps | | | | | | 0.00195599s [ 9.4%] solver (excl. callbacks) | | | | | | 0.000285788s [ 1.4%] creating output-file | | | | | | 0.00856421s [ 41.2%] event-handling | | | | | | 0.000110814s [ 0.5%] overhead | | | | | | 0.00922154s [ 44.4%] simulation | | | | | | 0.0207905s [100.0%] total | | | | | events | | | | | | 88 state events | | | | | | 30 time events | | | | | solver: dassl | | | | | | 2616 steps taken | | | | | | 3264 calls of functionODE | | | | | | 1304 evaluations of jacobian | | | | | | 58 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00247196s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.