Environment - simulationEnvironment: SPAWNPATH = /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master//Resources/bin/Spawn-light-0.6.0-638b8408fd/linux64/bin startTime=1.87488e+07 stopTime=1.93536e+07 tolerance=1e-06 numberOfIntervals=2513 stepSize=240.669 Regular simulation: ./Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Validation.OutputVariable.OneZoneOneOutputVariableSummer -abortSlowSimulation -alarm=240 -emit_protected -ignoreHideResult -lv LOG_STATS LOG_STDOUT | warning | The nominal value of zon.vol.m is 0, but it must be nonzero and finite. The solvers use 1.0 instead. EnergyPlus Starting EnergyPlus, Version 24.2.0-638b8408fd (No OpenGL), YMD=2026.11.17 23:40 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Warming up {11} Starting Simulation at 08/06/2006 for SPAWN-RUNPERIOD LOG_STDOUT | info | Output OneZoneOneOutputVariableSummer.equEle.y has in Modelica the unit 1. LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Fluid/Interfaces/PartialTwoPortInterface.mo:20:3-21:81:writable] | | | | The following assertion has been violated at time 18748800.000000 | | | | ((duc.m_flow >= 0.0 and duc.m_flow <= 1e5), duc.m_flow=-6.59347278997302e-15) --> "Variable violating min/max constraint: 0.0 <= duc.m_flow <= 1e5, has value: -6.59347e-15" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00616094s reading init.xml | | | | | | 0.000596912s reading info.xml | | | | | | 0.00014352s [ 0.0%] pre-initialization | | | | | | 5.31096s [ 94.8%] initialization | | | | | | 4.569e-06s [ 0.0%] steps | | | | | | 0.0115085s [ 0.2%] solver (excl. callbacks) | | | | | | 0.000747564s [ 0.0%] creating output-file | | | | | | 0.229401s [ 4.1%] event-handling | | | | | | 0.00404241s [ 0.1%] overhead | | | | | | 0.0441442s [ 0.8%] simulation | | | | | | 5.60095s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 1007 time events | | | | | solver: dassl | | | | | | 16077 steps taken | | | | | | 20278 calls of functionODE | | | | | | 11864 evaluations of jacobian | | | | | | 44 error test failures | | | | | | 0 convergence test failures | | | | | | 0.0247704s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing tabular output file results using HTML format. EnergyPlus Run Time=00hr 00min 0.47sec EnergyPlus Completed Successfully.