Environment - simulationEnvironment: SPAWNPATH = /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master//Resources/bin/Spawn-light-0.6.0-638b8408fd/linux64/bin startTime=7.344e+06 stopTime=7.776e+06 tolerance=1e-07 numberOfIntervals=2500 stepSize=172.8 Regular simulation: ./Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.IdealHeatingCoolingSpring -abortSlowSimulation -alarm=240 -emit_protected -ignoreHideResult -lv LOG_STATS LOG_STDOUT | warning | The nominal value of flo.cor.vol.m is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of flo.wes.vol.m is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of flo.nor.vol.m is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of flo.eas.vol.m is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of flo.sou.vol.m is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of flo.att.vol.m is 0, but it must be nonzero and finite. The solvers use 1.0 instead. EnergyPlus Starting EnergyPlus, Version 24.2.0-638b8408fd (No OpenGL), YMD=2026.11.17 23:40 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Starting Simulation at 03/27/2006 for SPAWN-RUNPERIOD LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0475437s reading init.xml | | | | | | 0.00380757s reading info.xml | | | | | | 0.00096307s [ 0.0%] pre-initialization | | | | | | 5.46132s [ 77.4%] initialization | | | | | | 3.7951e-05s [ 0.0%] steps | | | | | | 0.0978622s [ 1.4%] solver (excl. callbacks) | | | | | | 0.00288183s [ 0.0%] creating output-file | | | | | | 0.54138s [ 7.7%] event-handling | | | | | | 0.00703656s [ 0.1%] overhead | | | | | | 0.940185s [ 13.3%] simulation | | | | | | 7.05167s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 719 time events | | | | | solver: dassl | | | | | | 31521 steps taken | | | | | | 44517 calls of functionODE | | | | | | 9734 evaluations of jacobian | | | | | | 1176 error test failures | | | | | | 74 convergence test failures | | | | | | 0.76469s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing final SQL reports EnergyPlus Run Time=00hr 00min 1.88sec EnergyPlus Completed Successfully.