Environment - simulationEnvironment: SPAWNPATH = /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x//Resources/bin/Spawn-light-0.6.0-9f1b36b00b/linux64/bin startTime=1.6848e+07 stopTime=1.728e+07 tolerance=1e-07 numberOfIntervals=2500 stepSize=172.8 Regular simulation: ./Buildings_13_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.ASHRAE2006Summer -abortSlowSimulation -alarm=240 -lv LOG_STATS EnergyPlus Starting EnergyPlus, Version 24.2.0-9f1b36b00b, YMD=2026.11.17 23:57 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Warming up {11} Starting Simulation at 07/15/2006 for SPAWN-RUNPERIOD LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 16848060.000000 | | | | ((hvac.fanSup.etaHyd >= 0.0), hvac.fanSup.etaHyd=-1.183482782444825e-19) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.etaHyd, has value: -1.18348e-19" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 16848060.000000 | | | | ((hvac.fanSup.heaDis.etaHyd >= 0.0), hvac.fanSup.heaDis.etaHyd=-2.917499689356963e-15) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.heaDis.etaHyd, has value: -2.9175e-15" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 16848345.600000 | | | | ((hvac.VAVBox[1].VSup_flow >= 0.0), hvac.VAVBox[1].VSup_flow=-3.261640201741483e-14) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[1].VSup_flow, has value: -3.26164e-14" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 16848345.600000 | | | | ((hvac.VAVBox[2].VSup_flow >= 0.0), hvac.VAVBox[2].VSup_flow=-3.188472380828888e-15) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[2].VSup_flow, has value: -3.18847e-15" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 16848345.600000 | | | | ((hvac.VAVBox[3].VSup_flow >= 0.0), hvac.VAVBox[3].VSup_flow=-3.261640201741476e-14) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[3].VSup_flow, has value: -3.26164e-14" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 16848345.600000 | | | | ((hvac.VAVBox[4].VSup_flow >= 0.0), hvac.VAVBox[4].VSup_flow=-3.188472380828888e-15) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[4].VSup_flow, has value: -3.18847e-15" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 16848345.600000 | | | | ((hvac.VAVBox[5].VSup_flow >= 0.0), hvac.VAVBox[5].VSup_flow=-4.302561970634006e-14) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[5].VSup_flow, has value: -4.30256e-14" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:68:3-73:35:writable] | | | | The following assertion has been violated at time 16916428.800000 | | | | ((hvac.cooCoi.SHR >= 0.0 and hvac.cooCoi.SHR <= 1.0), hvac.cooCoi.SHR=-9.272967307392976e-09) --> "Variable violating min/max constraint: 0.0 <= hvac.cooCoi.SHR <= 1.0, has value: -9.27297e-09" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 16916601.600000 | | | | ((hvac.fanSup.eff.yMot >= 0.0), hvac.fanSup.eff.yMot=-6.192295440172306e-172) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.eff.yMot, has value: -6.1923e-172" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 16916601.600000 | | | | ((hvac.pumCooCoi.etaHyd >= 0.0), hvac.pumCooCoi.etaHyd=-6.079950491699319e-24) --> "Variable violating min constraint: 0.0 <= hvac.pumCooCoi.etaHyd, has value: -6.07995e-24" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 16916601.600000 | | | | ((hvac.pumCooCoi.heaDis.etaHyd >= 0.0), hvac.pumCooCoi.heaDis.etaHyd=-8.785269874439349e-22) --> "Variable violating min constraint: 0.0 <= hvac.pumCooCoi.heaDis.etaHyd, has value: -8.78527e-22" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 16916601.600000 | | | | ((hvac.pumCooCoi.eff.yMot >= 0.0), hvac.pumCooCoi.eff.yMot=-2.722164644071195e-121) --> "Variable violating min constraint: 0.0 <= hvac.pumCooCoi.eff.yMot, has value: -2.72216e-121" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:117:3-118:81:writable] | | | | The following assertion has been violated at time 17003347.200000 | | | | ((hvac.pumCooCoi.m_flow >= 0.0 and hvac.pumCooCoi.m_flow <= 1e5), hvac.pumCooCoi.m_flow=-4.107597735237213e-12) --> "Variable violating min/max constraint: 0.0 <= hvac.pumCooCoi.m_flow <= 1e5, has value: -4.1076e-12" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.123045s reading init.xml | | | | | | 0.0113145s reading info.xml | | | | | | 0.000446129s [ 0.0%] pre-initialization | | | | | | 5.49533s [ 19.8%] initialization | | | | | | 0.0058158s [ 0.0%] steps | | | | | | 1.16868s [ 4.2%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 1.61083s [ 5.8%] event-handling | | | | | | 0.0213811s [ 0.1%] overhead | | | | | | 19.4804s [ 70.1%] simulation | | | | | | 27.7828s [100.0%] total | | | | | events | | | | | | 41 state events | | | | | | 730 time events | | | | | solver: dassl | | | | | | 62870 steps taken | | | | | | 112279 calls of functionODE | | | | | | 46421 evaluations of jacobian | | | | | | 2740 error test failures | | | | | | 10458 convergence test failures | | | | | | 18.0345s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing final SQL reports EnergyPlus Run Time=00hr 00min 22.56sec EnergyPlus Completed Successfully.