Environment - simulationEnvironment: SPAWNPATH = /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x//Resources/bin/Spawn-light-0.6.0-9f1b36b00b/linux64/bin startTime=1.58112e+07 stopTime=1.6416e+07 tolerance=1e-06 numberOfIntervals=2500 stepSize=241.92 Regular simulation: ./Buildings_13_Buildings.Fluid.DXSystems.Cooling.AirSource.Examples.SpaceCooling -abortSlowSimulation -alarm=240 -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 15811200.000000 | | | | ((fan.nominalValuesDefineDefaultPressureCurve), fan.nominalValuesDefineDefaultPressureCurve=false) --> "*** Warning in SpaceCooling.fan: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 15811200.000000 | | | | ((fan1.nominalValuesDefineDefaultPressureCurve), fan1.nominalValuesDefineDefaultPressureCurve=false) --> "*** Warning in SpaceCooling.fan1: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 15811200.000000 | | | | ((fan2.nominalValuesDefineDefaultPressureCurve), fan2.nominalValuesDefineDefaultPressureCurve=false) --> "*** Warning in SpaceCooling.fan2: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/DXSystems/Cooling/BaseClasses/Evaporation.mo:185:3-194:27:writable] | | | | The following assertion has been violated during initialization at time 15811200.000000 | | | | ((varSpeDX.watVapEva.nomVal.gamma <= varSpeDX.watVapEva.gammaMax), varSpeDX.watVapEva.nomVal.gamma=1.5, varSpeDX.watVapEva.gammaMax=0.5268101234461572) --> "*** Warning: In DX coil model, gamma is too large for these coil conditions. | | | | Instead of gamma = 1.5, a value of 0.52681, which | | | | corresponds to a mass transfer effectiveness of 0.8, will be used. | | | | Coil nominal performance data are: | | | | nomVal.m_flow_nominal = 0.646123 | | | | dX_nominal = XEvaOut_nominal-XEvaWetBulOut_nominal = 0.00528111 - 0.00637893 = -0.00109782 | | | | QLat_flow_nominal = -2694 | | | | " LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/DXSystems/Cooling/BaseClasses/Evaporation.mo:185:3-194:27:writable] | | | | The following assertion has been violated during initialization at time 15811200.000000 | | | | ((mulStaDX.watVapEva.nomVal.gamma <= mulStaDX.watVapEva.gammaMax), mulStaDX.watVapEva.nomVal.gamma=1.5, mulStaDX.watVapEva.gammaMax=0.5268101234461572) --> "*** Warning: In DX coil model, gamma is too large for these coil conditions. | | | | Instead of gamma = 1.5, a value of 0.52681, which | | | | corresponds to a mass transfer effectiveness of 0.8, will be used. | | | | Coil nominal performance data are: | | | | nomVal.m_flow_nominal = 0.646123 | | | | dX_nominal = XEvaOut_nominal-XEvaWetBulOut_nominal = 0.00528111 - 0.00637893 = -0.00109782 | | | | QLat_flow_nominal = -2694 | | | | " LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/DXSystems/Cooling/BaseClasses/Evaporation.mo:185:3-194:27:writable] | | | | The following assertion has been violated during initialization at time 15811200.000000 | | | | ((sinSpeDX.watVapEva.nomVal.gamma <= sinSpeDX.watVapEva.gammaMax), sinSpeDX.watVapEva.nomVal.gamma=1.5, sinSpeDX.watVapEva.gammaMax=0.5268101234461572) --> "*** Warning: In DX coil model, gamma is too large for these coil conditions. | | | | Instead of gamma = 1.5, a value of 0.52681, which | | | | corresponds to a mass transfer effectiveness of 0.8, will be used. | | | | Coil nominal performance data are: | | | | nomVal.m_flow_nominal = 0.646123 | | | | dX_nominal = XEvaOut_nominal-XEvaWetBulOut_nominal = 0.00528111 - 0.00637893 = -0.00109782 | | | | QLat_flow_nominal = -2694 | | | | " LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/DXSystems/Cooling/BaseClasses/PartialCapacity.mo:121:7-134:38:writable] | | | | The following assertion has been violated at time 15849076.745968 | | | | ((not (sinSpeDX.dxCoi.TEvaIn > sinSpeDX.dxCoi.dryCoi.coiCap.sta[1].perCur.TEvaInMax or sinSpeDX.dxCoi.TEvaIn < sinSpeDX.dxCoi.dryCoi.coiCap.sta[1].perCur.TEvaInMin)), sinSpeDX.dxCoi.TEvaIn=297.0598175397607, sinSpeDX.dxCoi.dryCoi.coiCap.sta[1].perCur.TEvaInMax=297.03889, sinSpeDX.dxCoi.dryCoi.coiCap.sta[1].perCur.TEvaInMin=285.92778) --> "*** Warning: Evaporator temperature TEvaIn is out of bounds in DX coil model at time = 1.58491e+07. | | | | stage = 1 | | | | TEvaInMin = 285.928 Kelvin (12.7778 degC) | | | | TEvaIn = 297.06 Kelvin (23.9098 degC) | | | | TEvaInMax = 297.039 Kelvin (23.8889 degC) | | | | Extrapolation can introduce large errors. | | | | This warning will only be reported once for each stage." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/DXSystems/Cooling/BaseClasses/Evaporation.mo:59:3-62:61:writable] | | | | The following assertion has been violated at time 16401000.960000 | | | | ((sinSpeDX.watVapEva.m >= 0.0), sinSpeDX.watVapEva.m=-2.778945845621376e-07) --> "Variable violating min constraint: 0.0 <= sinSpeDX.watVapEva.m, has value: -2.77895e-07" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/DXSystems/Cooling/BaseClasses/Evaporation.mo:59:3-62:61:writable] | | | | The following assertion has been violated at time 16401000.960000 | | | | ((mulStaDX.watVapEva.m >= 0.0), mulStaDX.watVapEva.m=-1.342793513387183e-06) --> "Variable violating min constraint: 0.0 <= mulStaDX.watVapEva.m, has value: -1.34279e-06" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/DXSystems/Cooling/BaseClasses/Evaporation.mo:59:3-62:61:writable] | | | | The following assertion has been violated at time 16401000.960000 | | | | ((varSpeDX.watVapEva.m >= 0.0), varSpeDX.watVapEva.m=-4.462112203536645e-07) --> "Variable violating min constraint: 0.0 <= varSpeDX.watVapEva.m, has value: -4.46211e-07" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.057851s reading init.xml | | | | | | 0.00556687s reading info.xml | | | | | | 0.000185068s [ 0.0%] pre-initialization | | | | | | 0.0184427s [ 0.2%] initialization | | | | | | 3.1599e-05s [ 0.0%] steps | | | | | | 0.297635s [ 3.5%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 2.29913s [ 27.3%] event-handling | | | | | | 0.0109537s [ 0.1%] overhead | | | | | | 5.797s [ 68.8%] simulation | | | | | | 8.42338s [100.0%] total | | | | | events | | | | | | 2356 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 127647 steps taken | | | | | | 163129 calls of functionODE | | | | | | 34325 evaluations of jacobian | | | | | | 2685 error test failures | | | | | | 3 convergence test failures | | | | | | 3.04846s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.