Environment - simulationEnvironment: SPAWNPATH = /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x//Resources/bin/Spawn-light-0.5.0-ab07bde9bb/linux64/bin:/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x//Resources/bin/Spawn-light-0.6.0-9f1b36b00b/linux64/bin startTime=1.5552e+07 stopTime=1.5984e+07 tolerance=1e-06 numberOfIntervals=120 stepSize=3600 Regular simulation: ./Buildings_12_Buildings.Utilities.Plotters.Examples.SingleZoneVAV -abortSlowSimulation -alarm=240 -emit_protected -ignoreHideResult -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/Interfaces/PartialFourPortInterface.mo:23:3-24:84:writable] | | | | The following assertion has been violated at time 15616800.000000 | | | | ((hvac.cooCoi.m1_flow >= 0.0 and hvac.cooCoi.m1_flow <= 1e5), hvac.cooCoi.m1_flow=-5.048709793414476e-29) --> "Variable violating min/max constraint: 0.0 <= hvac.cooCoi.m1_flow <= 1e5, has value: -5.04871e-29" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/Interfaces/PartialTwoPortTransport.mo:34:3-36:69:writable] | | | | The following assertion has been violated at time 15705810.930204 | | | | ((hvac.ideVal.preMasFlo.m_flow >= 0.0 and hvac.ideVal.preMasFlo.m_flow <= 1e5), hvac.ideVal.preMasFlo.m_flow=-5.048709793414476e-29) --> "Variable violating min/max constraint: 0.0 <= hvac.ideVal.preMasFlo.m_flow <= 1e5, has value: -5.04871e-29" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.15405s reading init.xml | | | | | | 0.0128696s reading info.xml | | | | | | 0.00410606s [ 0.4%] pre-initialization | | | | | | 0.0292758s [ 2.8%] initialization | | | | | | 0.00115531s [ 0.1%] steps | | | | | | 0.0970466s [ 9.3%] solver (excl. callbacks) | | | | | | 0.00704448s [ 0.7%] creating output-file | | | | | | 0.137922s [ 13.2%] event-handling | | | | | | 0.00381095s [ 0.4%] overhead | | | | | | 0.761607s [ 73.1%] simulation | | | | | | 1.04197s [100.0%] total | | | | | events | | | | | | 41 state events | | | | | | 514 time events | | | | | solver: dassl | | | | | | 13419 steps taken | | | | | | 19124 calls of functionODE | | | | | | 6384 evaluations of jacobian | | | | | | 659 error test failures | | | | | | 1 convergence test failures | | | | | | 0.61705s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. LOG_STDOUT | info | Wrote plot file "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_12_Buildings.Utilities.Plotters.Examples.SingleZoneVAV/plots.html".