Environment - simulationEnvironment: SPAWNPATH = /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x//Resources/bin/Spawn-light-0.5.0-ab07bde9bb/linux64/bin:/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x//Resources/bin/Spawn-light-0.6.0-9f1b36b00b/linux64/bin startTime=0 stopTime=432000 tolerance=1e-06 numberOfIntervals=2500 stepSize=172.8 Regular simulation: ./Buildings_12_Buildings.ThermalZones.EnergyPlus_24_2_0.Validation.ZoneSurface.OneZoneConstantFloorTemperature -abortSlowSimulation -alarm=240 -emit_protected -ignoreHideResult -lv LOG_STATS EnergyPlus Starting EnergyPlus, Version 24.2.0-9f1b36b00b, YMD=2026.11.17 23:14 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Starting Simulation at 01/01/2006 for SPAWN-RUNPERIOD LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/Interfaces/PartialTwoPortInterface.mo:20:3-21:81:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((duc.m_flow >= 0.0 and duc.m_flow <= 1e5), duc.m_flow=-6.593472789973019e-15) --> "Variable violating min/max constraint: 0.0 <= duc.m_flow <= 1e5, has value: -6.59347e-15" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00783571s reading init.xml | | | | | | 0.000826403s reading info.xml | | | | | | 0.000179688s [ 0.0%] pre-initialization | | | | | | 5.43604s [ 96.8%] initialization | | | | | | 3.116e-06s [ 0.0%] steps | | | | | | 0.00768038s [ 0.1%] solver (excl. callbacks) | | | | | | 0.000774601s [ 0.0%] creating output-file | | | | | | 0.12997s [ 2.3%] event-handling | | | | | | 0.00338712s [ 0.1%] overhead | | | | | | 0.0369647s [ 0.7%] simulation | | | | | | 5.615s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 719 time events | | | | | solver: dassl | | | | | | 10269 steps taken | | | | | | 12538 calls of functionODE | | | | | | 8719 evaluations of jacobian | | | | | | 2 error test failures | | | | | | 0 convergence test failures | | | | | | 0.0216596s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing tabular output file results using HTML format. EnergyPlus Run Time=00hr 00min 0.36sec EnergyPlus Completed Successfully.