Environment - simulationEnvironment: SPAWNPATH = /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x//Resources/bin/Spawn-light-0.5.0-ab07bde9bb/linux64/bin:/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x//Resources/bin/Spawn-light-0.6.0-9f1b36b00b/linux64/bin startTime=0 stopTime=3600 tolerance=1e-06 numberOfIntervals=2500 stepSize=1.44 Regular simulation: ./Buildings_12_Buildings.Fluid.HeatExchangers.Examples.DryCoilEffectivenessNTUMassFlow -abortSlowSimulation -alarm=240 -emit_protected -ignoreHideResult -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/HeatExchangers/BaseClasses/PartialEffectivenessNTU.mo:178:5-187:38:writable] | | | | The following assertion has been violated at time 1998.720000 | | | | ((noEvent(hex.m1_flow > (-0.1) * hex.m1_flow_nominal) and noEvent(hex.m2_flow > (-0.1) * hex.m2_flow_nominal)), hex.m1_flow=0.001, hex.m1_flow_nominal=0.1, hex.m2_flow=-0.01456000000000014, hex.m2_flow_nominal=0.14) --> "*** Warning in DryCoilEffectivenessNTUMassFlow.hex: The flow direction reversed. | | | | However, because the constant use_dynamicFlowRegime is set to false, | | | | the model does not change equations based on the actual flow regime. | | | | To switch equations based on the actual flow regime during the simulation, | | | | set the constant use_dynamicFlowRegime=true. | | | | Note that this can lead to slow simulation because of events." LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00379715s reading init.xml | | | | | | 0.000360938s reading info.xml | | | | | | 0.000137979s [ 2.2%] pre-initialization | | | | | | 0.000313469s [ 5.1%] initialization | | | | | | 1.152e-06s [ 0.0%] steps | | | | | | 0.000478509s [ 7.7%] solver (excl. callbacks) | | | | | | 0.000333043s [ 5.4%] creating output-file | | | | | | 0.000231915s [ 3.8%] event-handling | | | | | | 0.00152875s [ 24.8%] overhead | | | | | | 0.00315143s [ 51.0%] simulation | | | | | | 0.00617625s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 5 time events | | | | | solver: dassl | | | | | | 572 steps taken | | | | | | 840 calls of functionODE | | | | | | 167 evaluations of jacobian | | | | | | 36 error test failures | | | | | | 0 convergence test failures | | | | | | 8.2175e-05s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.