Environment - simulationEnvironment: startTime=0 stopTime=86400 tolerance=1e-08 numberOfIntervals=2500 stepSize=34.56 Regular simulation: ./BuildingSystems_BuildingSystems.Fluid.HeatPumps.ModularReversible.Examples.Modular_OneRoomRadiator -abortSlowSimulation -alarm=240 -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:389:3-396:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pumHeaPumSou.nominalValuesDefineDefaultPressureCurve), pumHeaPumSou.nominalValuesDefineDefaultPressureCurve=false) --> "*** Warning in Modular_OneRoomRadiator.pumHeaPumSou: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/HeatPumps/ModularReversible/RefrigerantCycle/BaseClasses/PartialTableData2D.mo:144:3-149:28:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((heaPum.refCyc.refCycHeaPumCoo.mCon_flow_nominal <= heaPum.refCyc.refCycHeaPumCoo.mCon_flow_max), heaPum.refCyc.refCycHeaPumCoo.mCon_flow_nominal=0.9560229445506692, heaPum.refCyc.refCycHeaPumCoo.mCon_flow_max=0.8417370122437587) --> "In Modular_OneRoomRadiator.heaPum.refCyc.refCycHeaPumCoo: The nominal condenser mass flow rate (0.956023 kg/s) is bigger than the | | | | maximal value (0.841737 kg/s) for the table data | | | | when assuming a temperature spread between 3 and 10 K, as in EN 14511." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/HeatPumps/ModularReversible/RefrigerantCycle/BaseClasses/PartialTableData2D.mo:156:3-161:28:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((heaPum.refCyc.refCycHeaPumCoo.mEva_flow_nominal <= heaPum.refCyc.refCycHeaPumCoo.mEva_flow_max), heaPum.refCyc.refCycHeaPumCoo.mEva_flow_nominal=5.586420056128286, heaPum.refCyc.refCycHeaPumCoo.mEva_flow_max=3.031878906715791) --> "In Modular_OneRoomRadiator.heaPum.refCyc.refCycHeaPumCoo: The nominal evaporator mass flow rate (5.58642 kg/s) is bigger than the | | | | maximal value (3.03188 kg/s) for the table data | | | | when assuming a temperature spread between 3 and 10 K, as in EN 14511." LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0318667s reading init.xml | | | | | | 0.00291561s reading info.xml | | | | | | 0.000139732s [ 0.2%] pre-initialization | | | | | | 0.0191562s [ 22.1%] initialization | | | | | | 1.1902e-05s [ 0.0%] steps | | | | | | 0.0056914s [ 6.6%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.0194023s [ 22.4%] event-handling | | | | | | 0.00269873s [ 3.1%] overhead | | | | | | 0.0393915s [ 45.5%] simulation | | | | | | 0.0864918s [100.0%] total | | | | | events | | | | | | 13 state events | | | | | | 4 time events | | | | | solver: dassl | | | | | | 4145 steps taken | | | | | | 4972 calls of functionODE | | | | | | 462 evaluations of jacobian | | | | | | 78 error test failures | | | | | | 0 convergence test failures | | | | | | 0.0118002s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.