startTime=0 stopTime=1 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.0004 wasm-jit simulation: simulate(PowerSysPro.Examples.MediumNetworks.DoubleNetwork,startTime=0,stopTime=1,tolerance=1e-06,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="PowerSysPro_PowerSysPro.Examples.MediumNetworks.DoubleNetwork",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS") LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSysPro 2.1.3/package.mo:370:9-370:131:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not load8.U < load8.minU), load8.U=310.55989566511465, load8.minU=360.0) --> ">>> Voltage is below the minimum acceptable value for DoubleNetwork.load8" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSysPro 2.1.3/package.mo:370:9-370:131:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not load5.U < load5.minU), load5.U=340.94065236949245, load5.minU=360.0) --> ">>> Voltage is below the minimum acceptable value for DoubleNetwork.load5" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSysPro 2.1.3/package.mo:370:9-370:131:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not load4.U < load4.minU), load4.U=310.55989566511465, load4.minU=360.0) --> ">>> Voltage is below the minimum acceptable value for DoubleNetwork.load4" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSysPro 2.1.3/package.mo:370:9-370:131:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not load1.U < load1.minU), load1.U=340.94065236949245, load1.minU=360.0) --> ">>> Voltage is below the minimum acceptable value for DoubleNetwork.load1" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSysPro 2.1.3/package.mo:402:11-402:160:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((tra2.S <= 2.5e5), tra2.S=330588.5796655527) --> ">>> Apparent power flowing the transformer is exceeding the nominal power for DoubleNetwork.tra2" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 7.1585e-05s [ 0.8%] pre-initialization | | | | | | 0.00055307s [ 6.2%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0s [ 0.0%] solver (excl. callbacks) | | | | | | 1.152e-06s [ 0.0%] creating output-file | | | | | | 0s [ 0.0%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 0.00823766s [ 92.9%] simulation | | | | | | 0.00886347s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: euler | | | | | | 2500 steps taken | | | | | | 0 calls of functionODE | | | | | | 0 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.