startTime=432000 stopTime=864000 tolerance=1e-07 numberOfIntervals=2500 stepSize=172.8 wasm-jit simulation: simulate(Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.Guideline36Winter,startTime=432000,stopTime=864000,tolerance=1e-07,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="Buildings_13_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.Guideline36Winter",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS") EnergyPlus Starting EnergyPlus, Version 24.2.0-9f1b36b00b, YMD=2026.11.07 20:30 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Warming up {11} Starting Simulation at 01/06/2006 for SPAWN-RUNPERIOD LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 432000.000004 | | | | ((hvac.fanSup.etaHyd >= 0.0), hvac.fanSup.etaHyd=-1.1847351306314282e-13) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.etaHyd, has value: -1.18474e-13" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 432000.000004 | | | | ((hvac.fanSup.heaDis.etaHyd >= 0.0), hvac.fanSup.heaDis.etaHyd=-2.9205869547566616e-9) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.heaDis.etaHyd, has value: -2.92059e-09" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Sensors/VolumeFlowRate.mo:19:3-25:24:writable] | | | | The following assertion has been violated at time 432202.529229 | | | | ((hvac.VOut1.V_flow >= 0.0), hvac.VOut1.V_flow=-8.590916120254218e-17) --> "Variable violating min constraint: 0.0 <= hvac.VOut1.V_flow, has value: -8.59092e-17" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 453900.000000 | | | | ((hvac.conVAV[5].ala.not1.y), hvac.conVAV[5].ala.not1.y=false) --> "Warning: airflow is less than 50% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 453900.000000 | | | | ((hvac.conVAV[5].ala.not2.y), hvac.conVAV[5].ala.not2.y=false) --> "Warning: airflow is less than 70% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 500428.800000 | | | | ((hvac.fanSup.eff.yMot >= 0.0), hvac.fanSup.eff.yMot=-6.510906244631123e-76) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.eff.yMot, has value: -6.51091e-76" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 504403.200000 | | | | ((hvac.pumHeaCoi.etaHyd >= 0.0), hvac.pumHeaCoi.etaHyd=-9.985350024870509e-23) --> "Variable violating min constraint: 0.0 <= hvac.pumHeaCoi.etaHyd, has value: -9.98535e-23" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 504403.200000 | | | | ((hvac.pumHeaCoi.heaDis.etaHyd >= 0.0), hvac.pumHeaCoi.heaDis.etaHyd=-8.87901913816747e-22) --> "Variable violating min constraint: 0.0 <= hvac.pumHeaCoi.heaDis.etaHyd, has value: -8.87902e-22" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 504403.200000 | | | | ((hvac.pumHeaCoi.eff.yMot >= 0.0), hvac.pumHeaCoi.eff.yMot=-1.0520403120567955e-69) --> "Variable violating min constraint: 0.0 <= hvac.pumHeaCoi.eff.yMot, has value: -1.05204e-69" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Utilities/Psychrometrics/TDewPoi_pW.mo:5:3-9:74:writable] | | | | The following assertion has been violated at time 531878.400000 | | | | ((hvac.cooCoi.dryWetCalcs.TDewIn.p_w >= 100.0), hvac.cooCoi.dryWetCalcs.TDewIn.p_w=99.81572779242424) --> "Variable violating min constraint: 100.0 <= hvac.cooCoi.dryWetCalcs.TDewIn.p_w, has value: 99.8157" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:117:3-118:81:writable] | | | | The following assertion has been violated at time 759634.557808 | | | | ((hvac.pumHeaCoi.m_flow >= 0.0 and hvac.pumHeaCoi.m_flow <= 1e5), hvac.pumHeaCoi.m_flow=-2.6899687337977264e-12) --> "Variable violating min/max constraint: 0.0 <= hvac.pumHeaCoi.m_flow <= 1e5, has value: -2.68997e-12" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 0.000101972s [ 0.0%] pre-initialization | | | | | | 7.59331s [ 4.8%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 4.65298s [ 3.0%] solver (excl. callbacks) | | | | | | 6.0184e-05s [ 0.0%] creating output-file | | | | | | 11.5514s [ 7.3%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 133.868s [ 84.9%] simulation | | | | | | 157.665s [100.0%] total | | | | | events | | | | | | 2730 state events | | | | | | 3978 time events | | | | | solver: dassl | | | | | | 145866 steps taken | | | | | | 197681 calls of functionODE | | | | | | 86982 evaluations of jacobian | | | | | | 3680 error test failures | | | | | | 288 convergence test failures | | | | | | 123.661s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing final SQL reports EnergyPlus Run Time=00hr 02min 30.48sec EnergyPlus Completed Successfully.