Dynawo_dev test using OpenModelica

Total Frontend Backend SimCode Templates Compilation Simulation Verification
81 81 81 81 81 81 75 68

Test started: 2026-11-02 10:50:20
Total time taken: 0:35:25
System info: r7945-1: AMD Ryzen 9 PRO 7945 12-Core Processor, 63 GB RAM, Ubuntu 26.04.1 LTS

OpenModelica Version: v1.28.0-dev.1668+g77dd7f0e8f.rust
OpenModelicaLibraryTesting Changes

CommitDateAuthorSummary
3dc441d2026-11-01 15:55:29 +0100Martin SjölundRun the FMI jobs in the .CI/testing image (#383)

Tested Library: Dynawo_dev 2.0.0

{
 "path": "dynawo/sources/Models/Modelica/Dynawo",
 "sha": "b1d50a690a9e5b3a76210b353a7cfd0aa495e664",
 "support": "noSupport",
 "uses": {
  "Modelica": "3.2.3"
 },
 "version": "2.0.0-master",
 "wasm": {
  "2": {
   "generation": 1,
   "sha256": "abfbc4c7a83c7af72886aaa5d6f45e8ba409aa42ebc1baaf61a508a7514eb350",
   "systemLibraries": [
    "libc"
   ],
   "zipfile": "https://libraries.openmodelica.org/precompiled/wasm32-wasip1/omc-1/Dynawo-wasm32-wasip1-4eb0d74d63821cf7.zip"
  }
 },
 "zipfile": "https://github.com/dynawo/dynawo/archive/b1d50a690a9e5b3a76210b353a7cfd0aa495e664.zip"
}

BuildModel time limit: 660s
Simulation time limit: 240s
Default tolerance: 1e-06
Default number of intervals: 2500
Optimization level: Tool default

Reference Files: https://github.com/dynawo/dynawo (b1d50a690a9e5b3a76210b353a7cfd0aa495e664)

CommitDateAuthorSummary
b1d50a690a92026-10-28 09:24:42 +0100Joy El Feghali#4223 Add missing switchOffSignal in OM example

Verified using: v1.28.0-dev.1665+gdf4cfba.cmake (diffSimulationResults)

Flags:
setCommandLineOptions("--simCodeTarget=wasm-jit")
setCommandLineOptions("-d=nogen");
setCommandLineOptions("-d=initialization");
setCommandLineOptions("-d=backenddaeinfo");
setCommandLineOptions("-d=discreteinfo");
setCommandLineOptions("-d=stateselection");
setCommandLineOptions("-d=execstat");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");
setCommandLineOptions("--allowNonStandardModelica=implicitParameterStartAttribute,illegalConditionalContext");
Config:
{
 "extraCustomCommands": [
  "setCommandLineOptions(\"--allowNonStandardModelica=implicitParameterStartAttribute,illegalConditionalContext\");"
 ],
 "library": "Dynawo",
 "libraryVersion": "master",
 "libraryVersionNameForTests": "dev",
 "referenceFileExtension": "csv",
 "referenceFileNameDelimiter": ".",
 "referenceFiles": {
  "destination": "ReferenceFiles/Dynawo",
  "git-directory": "dynawo/sources/Models/Modelica/Dynawo/Examples/references",
  "giturl": "https://github.com/dynawo/dynawo"
 },
 "referenceFinalDot": "_res."
}

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

ModelVerifiedSimulateTotal buildModelParsingFrontendBackendSimCodeTemplatesCompileTotal Execution
Dynawo.Examples.BESS.WECC.BESSCurrentSource (sim)0.06 (6 verified)0.150.450.580.090.110.040.030.182.18
Dynawo.Examples.BESS.WECC.BESSCurrentSourceExternalPCS (sim)0.06 (6 verified)0.170.460.210.100.140.030.030.161.75
Dynawo.Examples.BESS.WECC.BESSCurrentSourceNoPPC (sim)0.05 (6 verified)0.100.260.240.050.070.020.020.101.65
Dynawo.Examples.ENTSOE.TestCase1 (sim)0.01 (4 verified)0.030.320.250.050.080.020.030.141.46
Dynawo.Examples.ENTSOE.TestCase2 (sim)0.01 (4 verified)0.050.200.210.030.050.010.010.091.37
Dynawo.Examples.ENTSOE.TestCase3 (sim)0.01 (4 verified)0.140.500.260.070.110.030.020.271.77
Dynawo.Examples.GridCodeSimulations.RunSimulations (sim)0.03 (15 verified)1.125.030.211.051.710.380.211.687.11
Dynawo.Examples.GridCodeSimulations.SheetSimulations.SheetI2Xcca (sim)0.46 (7 verified)0.170.590.210.130.240.040.040.152.25
Dynawo.Examples.GridCodeSimulations.SheetSimulations.SheetI2Xccb (sim)0.46 (7 verified)0.170.490.210.120.150.040.030.152.13
Dynawo.Examples.GridCodeSimulations.SheetSimulations.SheetI5 (sim)0.61 (7 verified)0.760.560.220.120.190.050.030.172.94
Dynawo.Examples.GridCodeSimulations.SheetSimulations.SheetI6 (sim)0.51 (7 verified)0.170.520.210.120.170.040.030.162.20
Dynawo.Examples.GridCodeSimulations.SheetSimulations.SheetI7QMax (sim)0.53 (7 verified)0.170.590.240.120.160.040.030.242.34
Dynawo.Examples.GridCodeSimulations.SheetSimulations.SheetI7QMin (sim)0.47 (7 verified)0.160.530.230.130.170.040.040.162.26
Dynawo.Examples.GridCodeSimulations.SheetSimulations.SheetI10 (sim)2.84 (8 verified)1.250.800.220.140.180.060.030.396.10
Dynawo.Examples.GridForming.EpriSmib (sim)0.01 (4 verified)0.030.240.210.050.070.020.020.091.18
Dynawo.Examples.GridForming.GridForming (sim)0.01 (10 verified)1.640.510.610.090.210.040.030.153.60
Dynawo.Examples.HVDC.HVDC (sim)0.36 (3/9 failed)1.200.440.210.100.110.030.030.173.44
Dynawo.Examples.IEEE14.TestCases.IEEE14CLA (sim) 0.010.520.210.100.210.030.040.141.53
Dynawo.Examples.IEEE14.TestCases.IEEE14DisconnectLine (sim)0.01 (18 verified)0.020.480.210.100.200.030.030.131.47
Dynawo.Examples.IEEE14.TestCases.IEEE14NoEvent (sim)0.01 (18 verified)0.010.660.270.110.270.030.030.211.74
Dynawo.Examples.IEEE57.TestCases.IEEE57DisconnectLine (sim)0.01 (3 verified)0.071.950.210.380.990.110.090.383.03
Dynawo.Examples.IEEE57.TestCases.IEEE57HvdcPsDisconnectLine (sim)0.01 (4 verified)0.092.390.210.360.920.120.190.813.47
Dynawo.Examples.IEEE57.TestCases.IEEE57NoEvent (sim)0.01 (18 verified)0.062.160.240.320.870.100.100.773.22
Dynawo.Examples.IEEE118.TestCases.IEEE118NoEvent (sim)0.01 (13 verified)0.626.740.211.212.830.360.252.088.43
Dynawo.Examples.IllustrativeExamples.DynaFlow.CoordinatedVControl (sim)0.01 (7 verified)0.010.120.210.020.030.010.010.051.15
Dynawo.Examples.IllustrativeExamples.DynaFlow.PhaseShifterTransformer (sim)0.01 (6 verified)0.010.100.210.020.030.010.010.041.13
Dynawo.Examples.InertialGrid.DoubleInertialGrid (sim)0.06 (2 verified)0.500.280.480.090.050.010.030.102.05
Dynawo.Examples.LoadFrequencyDependent.LoadAlphaBetaFrequencyDependent (sim)0.01 (2/3 failed)0.010.110.560.010.020.010.010.061.51
Dynawo.Examples.LoadFrequencyDependent.LoadZIPFrequencyDependent (sim)0.01 (3 verified)0.010.120.210.020.030.010.010.061.12
Dynawo.Examples.Nordic.TestCases.LoadFlow (sim)0.01 (7 verified)0.022.450.210.351.040.120.180.763.43
Dynawo.Examples.Nordic.TestCases.TestCase (sim)0.07 (6 verified)37.1612.190.212.153.920.550.495.0850.61
Dynawo.Examples.Photovoltaics.WECC.PVCurrentSource (sim)0.04 (4 verified)0.120.410.210.080.110.030.030.171.63
Dynawo.Examples.Photovoltaics.WECC.PVVoltageSource2 (sim)0.04 (4 verified)0.150.620.250.110.140.030.030.311.99
Dynawo.Examples.Photovoltaics.WECC.PVVoltageSource4 (sim)0.52 (4 verified)0.190.730.220.110.150.040.080.352.66
Dynawo.Examples.Photovoltaics.WECC.PVVoltageSourceNoPPC (sim)0.32 (4 verified)0.150.320.220.070.090.020.020.111.96
Dynawo.Examples.RVS.TestCases.LoadFlow (sim)0.01 (4/7 failed)8.741.990.230.371.020.120.110.3711.84
Dynawo.Examples.RVS.TestCases.TestA.TestAAlphaBetaLoadNoRestorative (sim)0.04 (2 verified)204.1241.040.753.686.851.222.4526.84246.90
Dynawo.Examples.RVS.TestCases.TestA.TestAAlphaBetaLoadRestorative (sim)0.04 (2 verified)217.5240.550.233.116.891.182.2627.11259.23
Dynawo.Examples.RVS.TestCases.TestA.TestAShuntNoRestorative (sim)0.05 (1/7 failed)135.8240.520.233.256.981.221.9527.11178.13
Dynawo.Examples.RVS.TestCases.TestB.TestBNoSvcLoadReset (sim)0.05 (7 verified)228.3042.780.263.138.141.352.9527.21272.31
Dynawo.Examples.RVS.TestCases.TestB.TestBNoSvcNoLoadReset (sim) 240.0538.140.232.696.361.071.8526.17279.30
Dynawo.Examples.RVS.TestCases.TestB.TestBSvcLoadReset (sim)0.05 (7 verified)208.9541.820.232.956.931.222.4428.28251.95
Dynawo.Examples.RVS.TestCases.TestB.TestBSvcNoLoadReset (sim)0.09 (7 verified)192.8646.020.914.127.671.442.6130.17240.86
Dynawo.Examples.SMIB.SMIBStepEfdPm (sim)0.02 (3 verified)0.020.160.220.030.040.010.010.061.29
Dynawo.Examples.SMIB.SMIBStepPm (sim)0.01 (3 verified)0.080.190.220.030.060.010.010.081.36
Dynawo.Examples.SMIB.Standard.GovCt2St4b (sim)0.02 (5 verified)0.040.360.210.060.110.030.020.141.48
Dynawo.Examples.SMIB.Standard.GovHydro4St4b (sim)0.01 (4 verified)0.060.270.210.050.070.020.020.111.42
Dynawo.Examples.SMIB.Standard.GovSteam1St4b2 (sim)0.02 (5 verified)0.070.260.210.050.070.020.020.111.47
Dynawo.Examples.SMIB.Standard.GovSteam1St4bPss2b1 (sim)0.01 (5 verified)0.050.370.250.080.100.030.030.141.56
Dynawo.Examples.SMIB.Standard.GovSteam1St4bPss2b3 (sim)0.01 (5 verified)0.260.440.220.080.140.030.030.151.80
Dynawo.Examples.SMIB.Standard.GovSteamEuSt4b (sim)0.01 (5 verified)0.060.370.220.050.100.020.020.171.52
Dynawo.Examples.SVarC.SVarCFaultImp (sim)0.01 (3 verified)0.010.110.230.040.020.010.010.031.14
Dynawo.Examples.SVarC.SVarCLoadVarQ (sim)0.01 (3 verified)0.010.100.250.020.020.010.010.041.11
Dynawo.Examples.SVarC.SVarCLoadVarQLarge (sim)0.01 (3 verified)0.010.110.220.030.020.010.010.041.11
Dynawo.Examples.SVarC.SVarCModeChange (sim)0.01 (3 verified)0.010.090.240.020.020.010.010.031.09
Dynawo.Examples.SVarC.SVarCStepURef (sim)0.01 (2 verified)0.010.090.220.020.020.010.010.031.08
Dynawo.Examples.SystemFrequencyResponse.ReducedOrderSFR (sim)0.01 (2 verified)0.010.040.250.010.010.000.010.011.00
Dynawo.Examples.SystemFrequencyResponse.SimplifiedSFR (sim)0.01 (2 verified)0.010.050.220.010.010.000.000.021.00
Dynawo.Examples.Wind.IEC.Neplan.WPP4ACurrentSource2015 (sim)0.06 (3/4 failed)0.341.150.240.280.450.080.080.272.79
Dynawo.Examples.Wind.IEC.Neplan.WPP4ACurrentSource2020 (sim) 0.201.270.220.280.510.090.080.312.58
Dynawo.Examples.Wind.IEC.Neplan.WPP4ACurrentSource2020FOCB (sim) 0.831.270.220.290.500.090.090.313.39
Dynawo.Examples.Wind.IEC.Neplan.WPP4ACurrentSource2020UDip (sim) 155.861.290.240.290.510.100.090.31159.36
Dynawo.Examples.Wind.IEC.Neplan.WPP4BCurrentSource2020 (sim)0.42 (3/4 failed)2.361.240.220.280.480.090.090.305.61
Dynawo.Examples.Wind.IEC.Neplan.WPP4BCurrentSource2020FOCB (sim)0.26 (3/4 failed)1.331.150.210.260.440.080.080.304.07
Dynawo.Examples.Wind.IEC.Neplan.WT4ACurrentSource2015 (sim)0.04 (3 verified)0.240.700.220.150.250.040.050.211.99
Dynawo.Examples.Wind.IEC.Neplan.WT4ACurrentSource2015FOCB (sim)0.03 (3 verified)0.170.670.210.150.240.040.050.191.93
Dynawo.Examples.Wind.IEC.Neplan.WT4ACurrentSource2020 (sim)0.06 (4 verified)0.230.750.210.170.240.050.050.242.10
Dynawo.Examples.Wind.IEC.Neplan.WT4ACurrentSource2020FOCB (sim)0.04 (4 verified)0.160.760.220.160.250.050.050.242.05
Dynawo.Examples.Wind.IEC.Neplan.WT4BCurrentSource2015 (sim)0.04 (3 verified)0.240.750.220.160.270.050.050.222.12
Dynawo.Examples.Wind.IEC.Neplan.WT4BCurrentSource2015FOCB (sim)0.03 (3 verified)0.170.750.240.170.270.050.050.212.08
Dynawo.Examples.Wind.IEC.Neplan.WT4BCurrentSource2020 (sim) 0.080.850.220.180.310.050.060.252.03
Dynawo.Examples.Wind.IEC.Neplan.WT4BCurrentSource2020FOCB (sim)0.04 (4 verified)0.180.890.220.220.300.060.060.252.21
Dynawo.Examples.Wind.WECC.WT3CurrentSource1 (sim)0.35 (4 verified)0.140.390.280.090.110.030.030.132.12
Dynawo.Examples.Wind.WECC.WT3CurrentSource2 (sim)0.38 (4 verified)0.150.430.250.100.120.030.030.152.16
Dynawo.Examples.Wind.WECC.WT4ACurrentSource (sim)0.31 (4 verified)0.120.320.250.070.080.020.030.121.95
Dynawo.Examples.Wind.WECC.WT4BCurrentSource (sim)0.27 (4 verified)0.120.300.240.070.080.020.020.121.87
Dynawo.Examples.Wind.WECC.WTG3CurrentSource1 (sim)0.55 (4 verified)0.180.570.240.130.180.050.040.172.57
Dynawo.Examples.Wind.WECC.WTG3CurrentSource2 (sim)0.60 (4 verified)0.250.720.250.200.260.050.040.172.83
Dynawo.Examples.Wind.WECC.WTG4ACurrentSource (sim)4.65 (4 verified)1.500.470.260.110.140.040.030.158.16
Dynawo.Examples.Wind.WECC.WTG4BCurrentSource (sim)0.37 (4 verified)0.170.450.230.100.150.030.030.142.15
Dynawo.Examples.Wind.WECC.WTG4BCurrentSourceExternalPCS (sim)5.28 (4 verified)1.960.460.220.100.140.030.030.159.16