startTime=0 stopTime=345600 tolerance=1e-06 numberOfIntervals=2755 stepSize=125.445 wasm-jit simulation: simulate(Buildings.DHC.Plants.Combined.Validation.AllElectricCWStorage,startTime=0,stopTime=345600,tolerance=1e-06,numberOfIntervals=2755,outputFormat="mat",variableFilter="time|pla.chi.y1.[0-9,]+.|pla.chiHea.y1.[0-9,]+.|pla.chiHea.y1Coo.[0-9,]+.|pla.ctl.y1HeaCooChiHea.[0-9,]+.|pla.ctl.cycTan.idxCycTan|pla.ctl.modConLoo.mode|pla.chi.m1_flow|pla.chi.m2_flow|pla.chiHea.m1_flow|pla.chiHea.m2_flow|pla.chiHea.m3_flow|pla.chiHea.m4_flow|pla.chi.chi.m2_flow|pla.chiHea.chi.[0-9,]+..m2_flow|pla.chi.mChiWatUni_flow_nominal|pla.chiHea.mChiWatUni_flow_nominal|pla.TChiWatSupSet|pla.TChiWatPriRet.T|pla.TChiWatSup.T|pla.chiHea.TEvaLvg.[0-9,]+.|pla.pumChiWat.y1.[0-9,]+.|pla.pumChiWat.pum.y_actual|pla.dpChiWatSet|pla.dpChiWat.p_rel|pla.pumChiWat.pum.dpMachine|pla.pumChiWat.dpPum_nominal|pla.mChiWatPri_flow.m_flow|pla.mChiWat_flow_nominal|pla.mChiWatChi_flow_min|pla.chiHea.chi.[0-9,]+..m1_flow|pla.chiHea.mConWatUni_flow_nominal|pla.THeaWatSupSet|pla.THeaWatPriRet.T|pla.THeaWatSup.T|pla.chiHea.TConLvg.[0-9,]+.|pla.pumHeaWat.y1.[0-9,]+.|pla.pumHeaWat.pum.y_actual|pla.dpHeaWatSet|pla.dpHeaWat.p_rel|pla.pumHeaWat.pum.dpMachine|pla.pumHeaWat.dpPum_nominal|pla.mHeaWatPri_flow.m_flow|pla.mHeaWat_flow_nominal|pla.mHeaWatChiHea_flow_min|pla.pumConWatCon.y1.[0-9,]+.|pla.pumConWatCon.y|pla.chiHea.m3_flow_nominal|pla.pumConWatEva.y1.[0-9,]+.|pla.pumConWatEva.y|pla.chiHea.m2_flow_nominal|pla.heaPum.y1.[0-9,]+.|pla.ctl.THeaPumSet|pla.TConWatHeaPumEnt.T|pla.TConWatHeaPumLvg.T|pla.heaPum.heaPum.m1_flow|pla.heaPum.heaPum.m1_flow_nominal|pla.TTan.[0-9,]+..T|pla.chiHea.valConSwi.[0-9,]+..y_actual|pla.chiHea.valEvaSwi.[0-9,]+..y_actual|pla.TConWatConChiEnt.T|pla.TConWatConChiLvg.T|pla.TConWatConRet.T|pla.TConWatHexCooEnt.T|pla.TConWatHexCooLvg.T",fileNamePrefix="Buildings_12_Buildings.DHC.Plants.Combined.Validation.AllElectricCWStorage",simflags="-abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS") LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((pla.pumChiWat.pum.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= pla.pumChiWat.pum.etaHyd, has value: -4.06519e-33" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((pla.pumHeaWat.pum.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= pla.pumHeaWat.pum.etaHyd, has value: -2.94453e-34" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((pla.pumConWatCon.pum.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= pla.pumConWatCon.pum.etaHyd, has value: -2.5843e-41" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((pla.pumConWatEva.pum.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= pla.pumConWatEva.pum.etaHyd, has value: -8.47551e-34" LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 14708.654596 | | | | ((pla.pumConWatCoo.pum.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= pla.pumConWatCoo.pum.eff.yMot, has value: -8.47185e-61" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/Actuators/BaseClasses/ActuatorSignal.mo:23:3-30:26:writable] | | | | The following assertion has been violated at time 15487.347841 | | | | ((pla.valConWatEvaMix.res3.y >= 0.0 and pla.valConWatEvaMix.res3.y <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= pla.valConWatEvaMix.res3.y <= 1.0, has value: 1" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Blocks/Interfaces.mo:329:5-330:56:writable] | | | | The following assertion has been violated at time 15487.347841 | | | | ((pla.valConWatEvaMix.actPos.y >= 0.0 and pla.valConWatEvaMix.actPos.y <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= pla.valConWatEvaMix.actPos.y <= 1.0, has value: -1.34059e-12" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 19067.586207 | | | | ((pla.heaPum.pum.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= pla.heaPum.pum.etaHyd, has value: -1.35693e-30" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 19067.586207 | | | | ((pla.heaPum.pum.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= pla.heaPum.pum.eff.yMot, has value: -1.59831e-41" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Blocks/Interfaces.mo:329:5-330:56:writable] | | | | The following assertion has been violated at time 27704.800012 | | | | ((pla.valBypTan.actPos.y >= 0.0 and pla.valBypTan.actPos.y <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= pla.valBypTan.actPos.y <= 1.0, has value: -1.01003e-17" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 46949.829092 | | | | ((pla.pumConWatEva.pum.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= pla.pumConWatEva.pum.eff.yMot, has value: -8.64837e-34" LOG_ASSERT | debug | Solving non-linear system 12806 failed at time=47031.8797844787. | | | | For more information please use -lv LOG_NLS. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 89723.976583 | | | | ((pla.pumConWatCoo.pum.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= pla.pumConWatCoo.pum.etaHyd, has value: -2.18641e-30" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/Actuators/BaseClasses/ActuatorSignal.mo:23:3-30:26:writable] | | | | The following assertion has been violated at time 89818.366606 | | | | ((pla.valBypTan.res3.y >= 0.0 and pla.valBypTan.res3.y <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= pla.valBypTan.res3.y <= 1.0, has value: -1.5079e-09" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/HeatExchangers/CoolingTowers/BaseClasses/Merkel.mo:93:3-94:53:writable] | | | | The following assertion has been violated at time 176124.283122 | | | | ((pla.coo.coo.per.FRWat >= 0.0 and pla.coo.coo.per.FRWat <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= pla.coo.coo.per.FRWat <= 1.0, has value: -1.17711e-15" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 259226.127292 | | | | ((pla.pumConWatCon.pum.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= pla.pumConWatCon.pum.eff.yMot, has value: -1.83265e-40" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 259419.528131 | | | | ((pla.pumChiWat.pum.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= pla.pumChiWat.pum.eff.yMot, has value: -2.50266e-219" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 4.4523e-05s [ 0.0%] pre-initialization | | | | | | 0.0319255s [ 0.1%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 2.59495s [ 8.4%] solver (excl. callbacks) | | | | | | 0.0352059s [ 0.1%] creating output-file | | | | | | 3.13752s [ 10.1%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 25.1488s [ 81.3%] simulation | | | | | | 30.9484s [100.0%] total | | | | | events | | | | | | 746 state events | | | | | | 478 time events | | | | | solver: dassl | | | | | | 51060 steps taken | | | | | | 77705 calls of functionODE | | | | | | 19101 evaluations of jacobian | | | | | | 2950 error test failures | | | | | | 557 convergence test failures | | | | | | 21.086s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.