Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo): time 0.5511/0.5511, allocations: 111.6 MB / 131.5 MB, free: 4.91 MB / 122.7 MB " [Timeout remaining time 179] Using package ThermoSysPro with version 4.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo) Running command: translateModel(ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC,tolerance=0.001,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC") translateModel(ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC,tolerance=0.001,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC") [Timeout 660] "Notification: Performance of FrontEnd - loaded program: time 1.503e-06/1.503e-06, allocations: 0 / 176.7 MB, free: 8.871 MB / 170.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 1.37e-05/1.52e-05, allocations: 2.312 kB / 176.7 MB, free: 8.867 MB / 170.7 MB Notification: Automatically loaded package Complex 4.1.0 due to uses annotation from Modelica. Notification: Automatically loaded package ModelicaServices 4.1.0 due to uses annotation from Modelica. Notification: Automatically loaded package Modelica 4.1.0 due to usage. Notification: Performance of NFInst.instantiate(ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC): time 1.35/1.35, allocations: 337.5 MB / 0.5021 GB, free: 264 kB / 426.7 MB Notification: Performance of NFInst.instExpressions: time 0.5027/1.853, allocations: 219.2 MB / 0.7162 GB, free: 3.762 MB / 0.6198 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.01443/1.867, allocations: 243.2 kB / 0.7165 GB, free: 3.762 MB / 0.6198 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:63:3-64:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:65:3-66:80:writable] Warning: Connector Cm is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:67:3-68:82:writable] Warning: Connector Cd is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:69:3-70:78:writable] Warning: Connector Cv is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:80:3-81:79:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:82:3-83:81:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:84:3-85:79:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:24:3-25:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:26:3-27:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:24:3-25:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:26:3-27:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:21:3-22:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:23:3-24:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:20:3-21:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:22:3-23:78:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:24:3-25:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:26:3-27:80:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:48:3-49:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:90:3-91:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:94:3-95:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:16:3-17:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:18:3-19:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:20:3-21:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:22:3-23:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:48:3-49:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:90:3-91:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:94:3-95:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:16:3-17:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:18:3-19:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:20:3-21:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:22:3-23:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:48:3-49:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:90:3-91:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:94:3-95:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:16:3-17:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:18:3-19:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:20:3-21:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:22:3-23:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:48:3-49:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:90:3-91:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:94:3-95:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:16:3-17:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:18:3-19:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:20:3-21:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:22:3-23:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:48:3-49:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:90:3-91:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:94:3-95:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:16:3-17:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:18:3-19:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:20:3-21:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:22:3-23:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:48:3-49:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:90:3-91:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:94:3-95:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:16:3-17:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:18:3-19:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:20:3-21:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:22:3-23:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:48:3-49:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:90:3-91:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:94:3-95:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:16:3-17:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:18:3-19:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:20:3-21:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:22:3-23:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:48:3-49:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:90:3-91:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:94:3-95:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:16:3-17:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:18:3-19:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:20:3-21:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:22:3-23:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:63:3-64:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:65:3-66:80:writable] Warning: Connector Cm is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:67:3-68:82:writable] Warning: Connector Cd is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:69:3-70:78:writable] Warning: Connector Cv is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:80:3-81:79:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:82:3-83:81:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:84:3-85:79:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:24:3-25:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:26:3-27:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:24:3-25:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:26:3-27:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:48:3-49:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:90:3-91:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:94:3-95:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:16:3-17:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:18:3-19:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:20:3-21:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:22:3-23:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:21:3-22:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:23:3-24:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:20:3-21:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:22:3-23:78:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:24:3-25:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:26:3-27:80:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:48:3-49:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:90:3-91:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:94:3-95:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:16:3-17:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:18:3-19:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:20:3-21:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:22:3-23:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:48:3-49:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:90:3-91:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:94:3-95:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:16:3-17:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:18:3-19:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:20:3-21:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:22:3-23:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeB.mo:20:3-21:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeB.mo:22:3-23:78:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeB.mo:24:3-25:78:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeB.mo:26:3-27:80:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:48:3-49:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:90:3-91:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:94:3-95:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:16:3-17:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:18:3-19:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:20:3-21:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:22:3-23:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:48:3-49:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:90:3-91:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:94:3-95:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:16:3-17:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:18:3-19:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:20:3-21:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:22:3-23:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:63:3-64:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:65:3-66:80:writable] Warning: Connector Cm is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:67:3-68:82:writable] Warning: Connector Cd is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:69:3-70:78:writable] Warning: Connector Cv is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:80:3-81:79:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:82:3-83:81:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:84:3-85:79:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:24:3-25:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:26:3-27:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:24:3-25:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:26:3-27:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:21:3-22:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:23:3-24:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:20:3-21:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:22:3-23:78:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:24:3-25:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:26:3-27:80:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:48:3-49:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:90:3-91:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:94:3-95:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:16:3-17:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:18:3-19:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:20:3-21:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:22:3-23:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:24:3-25:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:26:3-27:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:48:3-49:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:90:3-91:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:94:3-95:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:16:3-17:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:18:3-19:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:20:3-21:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:22:3-23:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/BoundaryConditions/SinkP.mo:13:3-14:80:writable] Warning: Connector C is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:48:3-49:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:90:3-91:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:94:3-95:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:16:3-17:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:18:3-19:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:20:3-21:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:22:3-23:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Machines/StodolaTurbine.mo:36:3-37:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Machines/StodolaTurbine.mo:38:3-39:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Machines/StodolaTurbine.mo:42:3-43:99:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Machines/StodolaTurbine.mo:36:3-37:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Machines/StodolaTurbine.mo:38:3-39:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Machines/StodolaTurbine.mo:42:3-43:99:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:20:3-21:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:22:3-23:78:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:24:3-25:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:26:3-27:80:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Machines/StodolaTurbine.mo:36:3-37:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Machines/StodolaTurbine.mo:38:3-39:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Machines/StodolaTurbine.mo:42:3-43:99:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Junctions/MassFlowMultiplier.mo:12:3-13:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Junctions/MassFlowMultiplier.mo:14:3-15:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Junctions/MassFlowMultiplier.mo:12:3-13:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Junctions/MassFlowMultiplier.mo:14:3-15:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Junctions/MassFlowMultiplier.mo:12:3-13:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Junctions/MassFlowMultiplier.mo:14:3-15:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/SimpleDynamicCondenser.mo:59:3-60:78:writable] Warning: Connector Cv is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/SimpleDynamicCondenser.mo:61:3-62:79:writable] Warning: Connector Cl is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/SimpleDynamicCondenser.mo:67:3-68:81:writable] Warning: Connector Cee is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/SimpleDynamicCondenser.mo:69:3-70:79:writable] Warning: Connector Cse is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/BoundaryConditions/SourceQ.mo:13:3-14:78:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/BoundaryConditions/SinkP.mo:19:3-20:80:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:21:3-22:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:23:3-24:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:20:3-21:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:22:3-23:78:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:24:3-25:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:26:3-27:80:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:21:3-22:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:23:3-24:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeA.mo:18:3-19:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeA.mo:20:3-21:78:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeA.mo:22:3-23:78:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeA.mo:26:3-27:80:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Machines/StaticCentrifugalPump.mo:33:3-34:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Machines/StaticCentrifugalPump.mo:35:3-36:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Machines/StaticCentrifugalPump.mo:33:3-34:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Machines/StaticCentrifugalPump.mo:35:3-36:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Junctions/MassFlowMultiplier.mo:12:3-13:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Junctions/MassFlowMultiplier.mo:14:3-15:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Junctions/MassFlowMultiplier.mo:12:3-13:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Junctions/MassFlowMultiplier.mo:14:3-15:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:21:3-22:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:23:3-24:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:21:3-22:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:23:3-24:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:21:3-22:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:23:3-24:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:21:3-22:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:23:3-24:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Machines/StaticCentrifugalPump.mo:33:3-34:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Machines/StaticCentrifugalPump.mo:35:3-36:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:21:3-22:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:23:3-24:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:24:3-25:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:26:3-27:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:8:3-9:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:10:3-11:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:8:3-9:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:10:3-11:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:8:3-9:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:10:3-11:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:8:3-9:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:10:3-11:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:8:3-9:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:10:3-11:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:8:3-9:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:10:3-11:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:8:3-9:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:10:3-11:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:8:3-9:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:10:3-11:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:8:3-9:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:10:3-11:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:21:3-22:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:23:3-24:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:24:3-25:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:26:3-27:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:20:3-21:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:22:3-23:78:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:24:3-25:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:26:3-27:80:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:20:3-21:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:22:3-23:78:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:24:3-25:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:26:3-27:80:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:24:3-25:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:26:3-27:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:24:3-25:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:26:3-27:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeD.mo:20:3-21:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeD.mo:22:3-23:78:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeD.mo:24:3-25:80:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeD.mo:26:3-27:78:writable] Warning: Connector Cs3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:20:3-21:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:22:3-23:78:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:24:3-25:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:26:3-27:80:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:24:3-25:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:26:3-27:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/BoundaryConditions/SourceQ.mo:14:3-15:78:writable] Warning: Connector C is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.01391/1.881, allocations: 4.628 MB / 0.721 GB, free: 3.762 MB / 0.6198 GB Notification: Performance of NFTyping.typeBindings: time 0.033/1.914, allocations: 14.25 MB / 0.7349 GB, free: 1.586 MB / 0.6198 GB Notification: Performance of NFTyping.typeClassSections: time 0.04792/1.962, allocations: 25.45 MB / 0.7598 GB, free: 280 kB / 0.6198 GB Notification: Performance of NFFlatten.flatten: time 0.0802/2.042, allocations: 84.94 MB / 0.8427 GB, free: 8.504 MB / 0.6667 GB Notification: Performance of NFFlatten.resolveConnections: time 0.04174/2.084, allocations: 25.96 MB / 0.868 GB, free: 15.58 MB / 0.698 GB Notification: Performance of NFEvalConstants.evaluate: time 0.08388/2.168, allocations: 40.21 MB / 0.9073 GB, free: 9.016 MB / 0.7292 GB Notification: Performance of NFSimplifyModel.simplify: time 0.04569/2.214, allocations: 27.21 MB / 0.9339 GB, free: 15.63 MB / 0.7605 GB Notification: Performance of NFPackage.collectConstants: time 0.0208/2.235, allocations: 5.712 MB / 0.9395 GB, free: 9.918 MB / 0.7605 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteam/IF97_packages.mo:470:9-470:27:writable] Warning: 'cv' is used uninitialized and may cause unexpected behaviour. This is deprecated and will become an error in future releases. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteam/IF97_packages.mo:525:9-525:27:writable] Warning: 'cv' is used uninitialized and may cause unexpected behaviour. This is deprecated and will become an error in future releases. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteam/IF97_packages.mo:708:9-708:27:writable] Warning: 'cv' is used uninitialized and may cause unexpected behaviour. This is deprecated and will become an error in future releases. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ph.mo:51:3-51:60:writable] Warning: 'dh1satp' is used uninitialized and may cause unexpected behaviour. This is deprecated and will become an error in future releases. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ph.mo:51:3-51:60:writable] Warning: 'dh2satp' is used uninitialized and may cause unexpected behaviour. This is deprecated and will become an error in future releases. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ph_der.mo:118:3-118:151:writable] Warning: 'du1satp_der' is used uninitialized and may cause unexpected behaviour. This is deprecated and will become an error in future releases. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ph_der.mo:118:3-118:151:writable] Warning: 'du2satp_der' is used uninitialized and may cause unexpected behaviour. This is deprecated and will become an error in future releases. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteam/IF97_packages.mo:964:9-964:35:writable] Warning: 'h' is used uninitialized and may cause unexpected behaviour. This is deprecated and will become an error in future releases. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ps.mo:51:3-51:60:writable] Warning: 'dh1satp' is used uninitialized and may cause unexpected behaviour. This is deprecated and will become an error in future releases. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ps.mo:51:3-51:60:writable] Warning: 'dh2satp' is used uninitialized and may cause unexpected behaviour. This is deprecated and will become an error in future releases. Notification: Performance of NFFlatten.collectFunctions: time 0.062/2.297, allocations: 32.15 MB / 0.9709 GB, free: 10.2 MB / 0.7917 GB Notification: Performance of NFScalarize.scalarize: time 0.02649/2.323, allocations: 17.92 MB / 0.9884 GB, free: 9.238 MB / 0.8073 GB Notification: Performance of NFVerifyModel.verify: time 0.04101/2.364, allocations: 18.38 MB / 1.006 GB, free: 7.797 MB / 0.823 GB Notification: Performance of NFConvertDAE.convert: time 0.612/2.976, allocations: 62.39 MB / 1.067 GB, free: 128.9 MB / 0.823 GB Notification: Performance of FrontEnd - DAE generated: time 7.634e-06/2.976, allocations: 2.969 kB / 1.067 GB, free: 128.9 MB / 0.823 GB Notification: Performance of FrontEnd: time 1.873e-06/2.976, allocations: 1.172 kB / 1.067 GB, free: 128.9 MB / 0.823 GB Notification: Performance of Transformations before backend: time 0.002091/2.978, allocations: 0 / 1.067 GB, free: 128.9 MB / 0.823 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 10686 * Number of variables: 10686 Notification: Performance of Generate backend data structure: time 0.1125/3.091, allocations: 46.88 MB / 1.113 GB, free: 114.4 MB / 0.823 GB Notification: Performance of prepare preOptimizeDAE: time 3.525e-05/3.091, allocations: 13.14 kB / 1.113 GB, free: 114.4 MB / 0.823 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.03664/3.127, allocations: 7.52 MB / 1.12 GB, free: 114.4 MB / 0.823 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.02738/3.155, allocations: 11.44 MB / 1.132 GB, free: 110.7 MB / 0.823 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.01193/3.167, allocations: 19.78 MB / 1.151 GB, free: 91.07 MB / 0.823 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.01436/3.181, allocations: 2.859 MB / 1.154 GB, free: 91.02 MB / 0.823 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.1019/3.283, allocations: 34.27 MB / 1.187 GB, free: 69.89 MB / 0.823 GB Notification: Performance of preOpt findStateOrder (simulation): time 0.001337/3.284, allocations: 45.86 kB / 1.187 GB, free: 69.87 MB / 0.823 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.01376/3.298, allocations: 1.141 MB / 1.188 GB, free: 68.73 MB / 0.823 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 0.0008268/3.299, allocations: 1.308 MB / 1.19 GB, free: 67.42 MB / 0.823 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.06961/3.369, allocations: 18.28 MB / 1.207 GB, free: 49.34 MB / 0.823 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.2772/3.646, allocations: 114.9 MB / 1.32 GB, free: 1.5 MB / 0.8855 GB Notification: Performance of preOpt comSubExp (simulation): time 0.3353/3.981, allocations: 33.91 MB / 1.353 GB, free: 267.6 MB / 0.9012 GB Notification: Performance of preOpt resolveLoops (simulation): time 0.03168/4.013, allocations: 10 MB / 1.363 GB, free: 267.3 MB / 0.9012 GB Notification: Performance of preOpt evalFunc (simulation): time 0.1165/4.129, allocations: 73.22 MB / 1.434 GB, free: 253.7 MB / 0.9012 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.04356/4.173, allocations: 22.26 MB / 1.456 GB, free: 240.5 MB / 0.9012 GB Notification: Performance of pre-optimization done (n=7248): time 4.703e-05/4.173, allocations: 0 / 1.456 GB, free: 240.5 MB / 0.9012 GB Notification: Performance of matching and sorting (n=7256): time 0.362/4.535, allocations: 124 MB / 1.577 GB, free: 125.4 MB / 0.9012 GB Notification: Performance of inlineWhenForInitialization (initialization): time 0.0002742/4.535, allocations: 0.9696 MB / 1.578 GB, free: 124.3 MB / 0.9012 GB Notification: Performance of selectInitializationVariablesDAE (initialization): time 0.006902/4.542, allocations: 7.849 MB / 1.585 GB, free: 118.4 MB / 0.9012 GB Notification: Performance of collectPreVariables (initialization): time 0.01131/4.553, allocations: 0.6546 MB / 1.586 GB, free: 118.2 MB / 0.9012 GB Notification: Performance of collectInitialEqns (initialization): time 0.003134/4.556, allocations: 6.206 MB / 1.592 GB, free: 112.9 MB / 0.9012 GB Notification: Performance of collectInitialBindings (initialization): time 0.02492/4.581, allocations: 25.67 MB / 1.617 GB, free: 90.6 MB / 0.9012 GB Notification: Performance of simplifyInitialFunctions (initialization): time 0.03337/4.615, allocations: 8.388 MB / 1.625 GB, free: 85.41 MB / 0.9012 GB Notification: Performance of setup shared object (initialization): time 3.047e-05/4.615, allocations: 302 kB / 1.626 GB, free: 85.12 MB / 0.9012 GB Notification: Performance of preBalanceInitialSystem (initialization): time 0.02491/4.64, allocations: 8.763 MB / 1.634 GB, free: 76.94 MB / 0.9012 GB Notification: Performance of partitionIndependentBlocks (initialization): time 0.02858/4.668, allocations: 14.25 MB / 1.648 GB, free: 62.72 MB / 0.9012 GB Notification: It was not possible to check the given initialization system for consistency symbolically, because the relevant equations are part of an algebraic loop. This is not supported yet. Notification: Performance of analyzeInitialSystem (initialization): time 0.3843/5.053, allocations: 57.19 MB / 1.704 GB, free: 246.4 MB / 0.9012 GB Notification: Performance of solveInitialSystemEqSystem (initialization): time 0.0001491/5.053, allocations: 26.31 kB / 1.704 GB, free: 246.4 MB / 0.9012 GB Notification: Performance of matching and sorting (n=8082) (initialization): time 0.1297/5.182, allocations: 40.96 MB / 1.744 GB, free: 244.1 MB / 0.9012 GB Notification: Performance of prepare postOptimizeDAE: time 0.0001278/5.183, allocations: 101.4 kB / 1.744 GB, free: 244.1 MB / 0.9012 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 0.0003448/5.183, allocations: 141.3 kB / 1.744 GB, free: 244.1 MB / 0.9012 GB Notification: Performance of postOpt tearingSystem (initialization): time 1.398/6.581, allocations: 0.6697 GB / 2.414 GB, free: 199.6 MB / 0.9168 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.01152/6.592, allocations: 3.585 MB / 2.417 GB, free: 197.1 MB / 0.9168 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.1605/6.753, allocations: 59.03 MB / 2.475 GB, free: 152 MB / 0.9168 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.02954/6.782, allocations: 2.289 MB / 2.477 GB, free: 150.8 MB / 0.9168 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.01549/6.798, allocations: 1.366 MB / 2.479 GB, free: 150.2 MB / 0.9168 GB Warning: Assuming fixed start value for the following 5 variables: regulation_Niveau_HP.pIsat.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real regulation_Niveau_MP.pIsat.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real regulation_Niveau_BP.pIsat.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real regulation_Niveau_Condenseur.pIsat.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real regulation_Niveau_Condenseur.pIsat1.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real Warning: The initial conditions are over specified. The following 4 initial equations are redundant, so they are removed from the initialization system: $DER.EconomiseurHP3.TwoPhaseFlowPipe.Q[4] = 0.0 $DER.SurchauffeurHP2.TwoPhaseFlowPipe.Q[1] = 0.0 $DER.SurchauffeurHP3.TwoPhaseFlowPipe.Q[1] = 0.0 $DER.SurchauffeurMP3.TwoPhaseFlowPipe.Q[1] = 0.0. Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 414 * Number of states: 0 () * Number of discrete variables: 269 ($PRE.regulation_Niveau_HP.pIsat.Integrateur1.x0,regulation_Niveau_HP.pIsat.Integrateur1.x0,$PRE.regulation_Niveau_MP.pIsat.Integrateur1.x0,regulation_Niveau_MP.pIsat.Integrateur1.x0,$PRE.regulation_Niveau_BP.pIsat.Integrateur1.x0,regulation_Niveau_BP.pIsat.Integrateur1.x0,$PRE.regulation_Niveau_Condenseur.pIsat.Integrateur1.x0,regulation_Niveau_Condenseur.pIsat.Integrateur1.x0,$PRE.regulation_Niveau_Condenseur.pIsat1.Integrateur1.x0,regulation_Niveau_Condenseur.pIsat1.Integrateur1.x0,BallonHP.Ce2.b,BallonHP.Ce3.b,BallonHP.Cs.a,VolumeEvapHP.Ce2.b,VolumeEvapHP.Ce3.b,BallonMP.Ce2.b,BallonMP.Ce3.b,BallonMP.Cs.a,VolumeEvapMP.Ce2.b,VolumeEvapMP.Ce3.b,MelangeurHPMP.Cs1.a,BallonBP.Ce2.b,BallonBP.Ce3.b,VolumeEvapBP.Ce2.b,VolumeEvapBP.Ce3.b,MelangeurPostTMP1.Ce3.b,VolumeCond1.Ce1.b,VolumeCond1.Ce2.b,VolumeAlimMPHP.Ce2.b,VolumeECO_HP1_2.Ce2.b,VolumeECO_HP1_2.Ce3.b,VolumeECO_HP2_3.Ce2.b,VolumeECO_HP2_3.Ce3.b,VolumePreTHP.Cs1.a,VolumePreTHP.Cs2.a,MelangeurPreTMP.Ce2.b,MelangeurPreTMP.Ce3.b,BallonHP.Ce1.a,BallonHP.Cm.a,BallonHP.Cd.b,BallonHP.Cv.b,BallonHP.Ce2.a,BallonHP.Ce3.a,BallonHP.Cs.b,vanne_alimentationHP.C1.a,vanne_alimentationHP.C2.b,vanne_vapeurHP.C1.a,vanne_vapeurHP.C2.b,GainChargeHP.C1.a,GainChargeHP.C2.b,VolumeEvapHP.Ce1.a,VolumeEvapHP.Ce2.a,VolumeEvapHP.Cs.b,VolumeEvapHP.Ce3.a,EvaporateurHP.ExchangerFlueGasesMetal.C1.a,EvaporateurHP.ExchangerFlueGasesMetal.C2.b,EvaporateurHP.TwoPhaseFlowPipe.C1.a,EvaporateurHP.TwoPhaseFlowPipe.C2.b,EconomiseurHP4.ExchangerFlueGasesMetal.C1.a,EconomiseurHP4.ExchangerFlueGasesMetal.C2.b,EconomiseurHP4.TwoPhaseFlowPipe.C1.a,EconomiseurHP4.TwoPhaseFlowPipe.C2.b,SurchauffeurHP1.ExchangerFlueGasesMetal.C1.a,SurchauffeurHP1.ExchangerFlueGasesMetal.C2.b,SurchauffeurHP1.TwoPhaseFlowPipe.C1.a,SurchauffeurHP1.TwoPhaseFlowPipe.C2.b,EconomiseurHP3.ExchangerFlueGasesMetal.C1.a,EconomiseurHP3.ExchangerFlueGasesMetal.C2.b,EconomiseurHP3.TwoPhaseFlowPipe.C1.a,EconomiseurHP3.TwoPhaseFlowPipe.C2.b,EconomiseurHP2.ExchangerFlueGasesMetal.C1.a,EconomiseurHP2.ExchangerFlueGasesMetal.C2.b,EconomiseurHP2.TwoPhaseFlowPipe.C1.a,EconomiseurHP2.TwoPhaseFlowPipe.C2.b,EconomiseurHP1.ExchangerFlueGasesMetal.C1.a,EconomiseurHP1.ExchangerFlueGasesMetal.C2.b,EconomiseurHP1.TwoPhaseFlowPipe.C1.a,EconomiseurHP1.TwoPhaseFlowPipe.C2.b,SurchauffeurHP2.ExchangerFlueGasesMetal.C1.a,SurchauffeurHP2.ExchangerFlueGasesMetal.C2.b,SurchauffeurHP2.TwoPhaseFlowPipe.C1.a,SurchauffeurHP2.TwoPhaseFlowPipe.C2.b,SurchauffeurHP3.ExchangerFlueGasesMetal.C1.a,SurchauffeurHP3.ExchangerFlueGasesMetal.C2.b,SurchauffeurHP3.TwoPhaseFlowPipe.C1.a,SurchauffeurHP3.TwoPhaseFlowPipe.C2.b,BallonMP.Ce1.a,BallonMP.Cm.a,BallonMP.Cd.b,BallonMP.Cv.b,BallonMP.Ce2.a,BallonMP.Ce3.a,BallonMP.Cs.b,vanne_alimentationMP.C1.a,vanne_alimentationMP.C2.b,vanne_vapeurMP.C1.a,vanne_vapeurMP.C2.b,EvaporateurMP.ExchangerFlueGasesMetal.C1.a,EvaporateurMP.ExchangerFlueGasesMetal.C2.b,EvaporateurMP.TwoPhaseFlowPipe.C1.a,EvaporateurMP.TwoPhaseFlowPipe.C2.b,GainChargeMP.C1.a,GainChargeMP.C2.b,VolumeEvapMP.Ce1.a,VolumeEvapMP.Ce2.a,VolumeEvapMP.Cs.b,VolumeEvapMP.Ce3.a,EconomiseurMP.ExchangerFlueGasesMetal.C1.a,EconomiseurMP.ExchangerFlueGasesMetal.C2.b,EconomiseurMP.TwoPhaseFlowPipe.C1.a,EconomiseurMP.TwoPhaseFlowPipe.C2.b,SurchauffeurMP1.ExchangerFlueGasesMetal.C1.a,SurchauffeurMP1.ExchangerFlueGasesMetal.C2.b,SurchauffeurMP1.TwoPhaseFlowPipe.C1.a,SurchauffeurMP1.TwoPhaseFlowPipe.C2.b,MelangeurHPMP.Ce1.a,MelangeurHPMP.Ce2.a,MelangeurHPMP.Cs1.b,MelangeurHPMP.Cs2.b,SurchauffeurMP2.ExchangerFlueGasesMetal.C1.a,SurchauffeurMP2.ExchangerFlueGasesMetal.C2.b,SurchauffeurMP2.TwoPhaseFlowPipe.C1.a,SurchauffeurMP2.TwoPhaseFlowPipe.C2.b,SurchauffeurMP3.ExchangerFlueGasesMetal.C1.a,SurchauffeurMP3.ExchangerFlueGasesMetal.C2.b,SurchauffeurMP3.TwoPhaseFlowPipe.C1.a,SurchauffeurMP3.TwoPhaseFlowPipe.C2.b,BallonBP.Ce1.a,BallonBP.Cm.a,BallonBP.Cd.b,BallonBP.Cv.b,BallonBP.Ce2.a,BallonBP.Ce3.a,BallonBP.Cs.b,vanne_vapeurBP.C1.a,vanne_vapeurBP.C2.b,vanne_alimentationBP.C1.a,vanne_alimentationBP.C2.b,GainChargeBP.C1.a,GainChargeBP.C2.b,VolumeEvapBP.Ce1.a,VolumeEvapBP.Ce2.a,VolumeEvapBP.Cs.b,VolumeEvapBP.Ce3.a,EvaporateurBP.ExchangerFlueGasesMetal.C1.a,EvaporateurBP.ExchangerFlueGasesMetal.C2.b,EvaporateurBP.TwoPhaseFlowPipe.C1.a,EvaporateurBP.TwoPhaseFlowPipe.C2.b,Vanne_alimentationMPHP.C1.a,Vanne_alimentationMPHP.C2.b,SurchauffeurBP.ExchangerFlueGasesMetal.C1.a,SurchauffeurBP.ExchangerFlueGasesMetal.C2.b,SurchauffeurBP.TwoPhaseFlowPipe.C1.a,SurchauffeurBP.TwoPhaseFlowPipe.C2.b,PuitsFumees.C.a,EconomiseurBP.ExchangerFlueGasesMetal.C1.a,EconomiseurBP.ExchangerFlueGasesMetal.C2.b,EconomiseurBP.TwoPhaseFlowPipe.C1.a,EconomiseurBP.TwoPhaseFlowPipe.C2.b,TurbineHP.Ce.a,TurbineHP.Cs.b,TurbineMP.Ce.a,TurbineMP.Cs.b,MelangeurPostTMP1.Ce1.a,MelangeurPostTMP1.Ce2.a,MelangeurPostTMP1.Cs.b,MelangeurPostTMP1.Ce3.a,TurbineBP.Ce.a,TurbineBP.Cs.b,DoubleDebitHP.Ce.a,DoubleDebitHP.Cs.b,DoubleDebitMP.Ce.a,DoubleDebitMP.Cs.b,MoitieDebitHP.Ce.a,MoitieDebitHP.Cs.b,Condenseur.Cv.a,Condenseur.Cl.b,Condenseur.Cee.a,Condenseur.Cse.b,SourceCaloporteur.C.b,PuitsCaloporteur.C.a,perteChargeK1.C1.a,perteChargeK1.C2.b,VolumeCond1.Ce1.a,VolumeCond1.Ce2.a,VolumeCond1.Cs.b,VolumeCond1.Ce3.a,perteChargeKCond1.C1.a,perteChargeKCond1.C2.b,VolumeAlimMPHP.Ce1.a,VolumeAlimMPHP.Ce2.a,VolumeAlimMPHP.Cs1.b,VolumeAlimMPHP.Cs2.b,PompeAlimMP.C1.a,PompeAlimMP.C2.b,PompeAlimHP.C1.a,PompeAlimHP.C2.b,MoitieDebitBP.Ce.a,MoitieDebitBP.Cs.b,DoubleDebitBP.Ce.a,DoubleDebitBP.Cs.b,PerteChargeZero2.C1.a,PerteChargeZero2.C2.b,perteChargeK3.C1.a,perteChargeK3.C2.b,perteChargeK8.C1.a,perteChargeK8.C2.b,perteChargeK.C1.a,perteChargeK.C2.b,PompeAlimBP.C1.a,PompeAlimBP.C2.b,perteChargeK2.C1.a,perteChargeK2.C2.b,vanne_extraction.C1.a,vanne_extraction.C2.b,CapteurDebitVapHP.C1.a,CapteurDebitVapHP.C2.b,CapteurDebitEauHP.C1.a,CapteurDebitEauHP.C2.b,CapteurDebitEauMP.C1.a,CapteurDebitEauMP.C2.b,CapteurDebitVapMP.C1.a,CapteurDebitVapMP.C2.b,CapteurDebitVapBP.C1.a,CapteurDebitVapBP.C2.b,CapteurDebitEauBP.C1.a,CapteurDebitEauBP.C2.b,CapteurDebitEauBPsortie.C1.a,CapteurDebitEauBPsortie.C2.b,CapteurDebitEauCondenseur.C1.a,CapteurDebitEauCondenseur.C2.b,CapteurDebitVapCondenseur.C1.a,CapteurDebitVapCondenseur.C2.b,lumpedStraightPipeK2.C1.a,lumpedStraightPipeK2.C2.b,vanne_entree_TurbineHP.C1.a,vanne_entree_TurbineHP.C2.b,VolumeECO_HP1_2.Ce1.a,VolumeECO_HP1_2.Ce2.a,VolumeECO_HP1_2.Cs.b,VolumeECO_HP1_2.Ce3.a,VolumeECO_HP2_3.Ce1.a,VolumeECO_HP2_3.Ce2.a,VolumeECO_HP2_3.Cs.b,VolumeECO_HP2_3.Ce3.a,Vanne_alimentationMPHP1.C1.a,Vanne_alimentationMPHP1.C2.b,Vanne_alimentationMPHP2.C1.a,Vanne_alimentationMPHP2.C2.b,VolumePreTHP.Ce.a,VolumePreTHP.Cs1.b,VolumePreTHP.Cs2.b,VolumePreTHP.Cs3.b,MelangeurPreTMP.Ce1.a,MelangeurPreTMP.Ce2.a,MelangeurPreTMP.Cs.b,MelangeurPreTMP.Ce3.a,vanne_entree_TurbineMP.C1.a,vanne_entree_TurbineMP.C2.b,SourceFumees.C.b,regulation_Niveau_HP.pIsat.Integrateur1.reset.signal,regulation_Niveau_MP.pIsat.Integrateur1.reset.signal,regulation_Niveau_BP.pIsat.Integrateur1.reset.signal,regulation_Niveau_Condenseur.pIsat.Integrateur1.reset.signal,regulation_Niveau_Condenseur.echelon.yL.signal,regulation_Niveau_Condenseur.edge.yL.signal,regulation_Niveau_Condenseur.edge.uL.signal,$PRE.regulation_Niveau_Condenseur.edge.uL.signal,$whenCondition1) * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (1368): * Single equations (assignments): 1299 * Array equations: 0 * Algorithm blocks: 2 * Record equations: 49 * When equations: 0 * If-equations: 0 * Equation systems (not torn): 5 * Torn equation systems: 13 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 0 systems * Non-linear Jacobian (size): 5 systems {1, 1, 1, 1, 1} * Without analytic Jacobian (size): 0 systems Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 2 systems {(4,1,62.5%), (1,1,100.0%)} * Non-linear torn systems (#iteration vars, #inner vars): 11 systems {(1,1), (1,15), (1,1), (1,3), (2,11), (1,15), (318,2904), (1,1), (1,1), (1,1), (1,1)} Notification: Performance of prepare postOptimizeDAE: time 0.03219/6.83, allocations: 1.954 MB / 2.481 GB, free: 149.6 MB / 0.9168 GB Notification: Performance of postOpt lateInlineFunction (simulation): time 0.02784/6.858, allocations: 2.778 MB / 2.483 GB, free: 147.9 MB / 0.9168 GB Notification: Performance of postOpt wrapFunctionCalls (simulation): time 0.1614/7.019, allocations: 59.72 MB / 2.542 GB, free: 107.4 MB / 0.9168 GB Notification: Performance of postOpt inlineArrayEqn (simulation): time 0.118/7.137, allocations: 44.65 MB / 2.585 GB, free: 71.64 MB / 0.9168 GB Notification: Performance of postOpt constantLinearSystem (simulation): time 0.0001884/7.137, allocations: 24 kB / 2.585 GB, free: 71.61 MB / 0.9168 GB Notification: Performance of postOpt simplifysemiLinear (simulation): time 0.001147/7.138, allocations: 286.3 kB / 2.586 GB, free: 71.61 MB / 0.9168 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of postOpt removeSimpleEquations (simulation): time 0.5838/7.722, allocations: 101.8 MB / 2.685 GB, free: 230 MB / 0.9168 GB Notification: Performance of postOpt simplifyComplexFunction (simulation): time 0.0006694/7.723, allocations: 63.94 kB / 2.685 GB, free: 230 MB / 0.9168 GB Notification: Performance of postOpt solveSimpleEquations (simulation): time 0.04391/7.767, allocations: 11.9 MB / 2.697 GB, free: 230 MB / 0.9168 GB Notification: Performance of postOpt tearingSystem (simulation): time 0.08471/7.852, allocations: 38.46 MB / 2.734 GB, free: 226.5 MB / 0.9168 GB Notification: Performance of postOpt inputDerivativesUsed (simulation): time 0.0162/7.868, allocations: 1.648 MB / 2.736 GB, free: 226.5 MB / 0.9168 GB Notification: Performance of postOpt calculateStrongComponentJacobians (simulation): time 0.1313/7.999, allocations: 201.3 MB / 2.932 GB, free: 74.11 MB / 0.9324 GB Notification: Performance of postOpt calculateStateSetsJacobians (simulation): time 5.39e-06/7.999, allocations: 11.75 kB / 2.932 GB, free: 74.11 MB / 0.9324 GB Notification: Performance of postOpt symbolicJacobian (simulation): time 0.2122/8.211, allocations: 68.62 MB / 2.999 GB, free: 18.3 MB / 0.9324 GB Notification: Performance of postOpt removeConstants (simulation): time 0.02766/8.239, allocations: 7.673 MB / 3.007 GB, free: 14.19 MB / 0.9324 GB Notification: Performance of postOpt simplifyTimeIndepFuncCalls (simulation): time 0.01601/8.255, allocations: 1.149 MB / 3.008 GB, free: 13.04 MB / 0.9324 GB Notification: Performance of postOpt simplifyAllExpressions (simulation): time 0.0302/8.285, allocations: 2.389 MB / 3.01 GB, free: 10.65 MB / 0.9324 GB Notification: Performance of postOpt findZeroCrossings (simulation): time 0.01746/8.303, allocations: 4.172 MB / 3.014 GB, free: 6.5 MB / 0.9324 GB Notification: Performance of postOpt collapseArrayExpressions (simulation): time 0.0119/8.314, allocations: 1.447 MB / 3.016 GB, free: 5.051 MB / 0.9324 GB Notification: Performance of sorting global known variables: time 0.00421/8.319, allocations: 4.002 MB / 3.02 GB, free: 1.566 MB / 0.9324 GB Notification: Performance of sort global known variables: time 2.7e-07/8.319, allocations: 0 / 3.02 GB, free: 1.566 MB / 0.9324 GB Notification: Performance of remove unused functions: time 0.3637/8.682, allocations: 15.06 MB / 3.034 GB, free: 232.1 MB / 0.9324 GB Notification: Model statistics after passing the back-end for simulation: * Number of independent subsystems: 40 * Number of states: 249 (BallonHP.P,BallonHP.hl,BallonHP.hv,BallonHP.Tp,BallonHP.Vv,VolumeEvapHP.h,EvaporateurHP.ExchangerWall.Tp[1],EvaporateurHP.ExchangerWall.Tp[2],EvaporateurHP.ExchangerWall.Tp[3],EvaporateurHP.TwoPhaseFlowPipe.P[2],EvaporateurHP.TwoPhaseFlowPipe.P[3],EvaporateurHP.TwoPhaseFlowPipe.P[4],EvaporateurHP.TwoPhaseFlowPipe.Q[1],EvaporateurHP.TwoPhaseFlowPipe.Q[2],EvaporateurHP.TwoPhaseFlowPipe.Q[3],EvaporateurHP.TwoPhaseFlowPipe.Q[4],EvaporateurHP.TwoPhaseFlowPipe.h[2],EvaporateurHP.TwoPhaseFlowPipe.h[3],EvaporateurHP.TwoPhaseFlowPipe.h[4],EconomiseurHP4.ExchangerWall.Tp[1],EconomiseurHP4.ExchangerWall.Tp[2],EconomiseurHP4.ExchangerWall.Tp[3],EconomiseurHP4.TwoPhaseFlowPipe.P[2],EconomiseurHP4.TwoPhaseFlowPipe.P[3],EconomiseurHP4.TwoPhaseFlowPipe.P[4],EconomiseurHP4.TwoPhaseFlowPipe.Q[2],EconomiseurHP4.TwoPhaseFlowPipe.Q[3],EconomiseurHP4.TwoPhaseFlowPipe.Q[4],EconomiseurHP4.TwoPhaseFlowPipe.h[2],EconomiseurHP4.TwoPhaseFlowPipe.h[3],EconomiseurHP4.TwoPhaseFlowPipe.h[4],SurchauffeurHP1.ExchangerWall.Tp[1],SurchauffeurHP1.ExchangerWall.Tp[2],SurchauffeurHP1.ExchangerWall.Tp[3],SurchauffeurHP1.TwoPhaseFlowPipe.P[2],SurchauffeurHP1.TwoPhaseFlowPipe.P[3],SurchauffeurHP1.TwoPhaseFlowPipe.P[4],SurchauffeurHP1.TwoPhaseFlowPipe.Q[1],SurchauffeurHP1.TwoPhaseFlowPipe.Q[2],SurchauffeurHP1.TwoPhaseFlowPipe.Q[3],SurchauffeurHP1.TwoPhaseFlowPipe.h[2],SurchauffeurHP1.TwoPhaseFlowPipe.h[3],SurchauffeurHP1.TwoPhaseFlowPipe.h[4],EconomiseurHP3.ExchangerWall.Tp[1],EconomiseurHP3.ExchangerWall.Tp[2],EconomiseurHP3.ExchangerWall.Tp[3],EconomiseurHP3.TwoPhaseFlowPipe.P[2],EconomiseurHP3.TwoPhaseFlowPipe.P[3],EconomiseurHP3.TwoPhaseFlowPipe.P[4],EconomiseurHP3.TwoPhaseFlowPipe.Q[1],EconomiseurHP3.TwoPhaseFlowPipe.Q[2],EconomiseurHP3.TwoPhaseFlowPipe.Q[3],EconomiseurHP3.TwoPhaseFlowPipe.Q[4],EconomiseurHP3.TwoPhaseFlowPipe.h[2],EconomiseurHP3.TwoPhaseFlowPipe.h[3],EconomiseurHP3.TwoPhaseFlowPipe.h[4],EconomiseurHP2.ExchangerWall.Tp[1],EconomiseurHP2.ExchangerWall.Tp[2],EconomiseurHP2.ExchangerWall.Tp[3],EconomiseurHP2.TwoPhaseFlowPipe.P[2],EconomiseurHP2.TwoPhaseFlowPipe.P[3],EconomiseurHP2.TwoPhaseFlowPipe.P[4],EconomiseurHP2.TwoPhaseFlowPipe.Q[1],EconomiseurHP2.TwoPhaseFlowPipe.Q[2],EconomiseurHP2.TwoPhaseFlowPipe.Q[3],EconomiseurHP2.TwoPhaseFlowPipe.Q[4],EconomiseurHP2.TwoPhaseFlowPipe.h[2],EconomiseurHP2.TwoPhaseFlowPipe.h[3],EconomiseurHP2.TwoPhaseFlowPipe.h[4],EconomiseurHP1.ExchangerWall.Tp[1],EconomiseurHP1.ExchangerWall.Tp[2],EconomiseurHP1.ExchangerWall.Tp[3],EconomiseurHP1.TwoPhaseFlowPipe.P[2],EconomiseurHP1.TwoPhaseFlowPipe.P[3],EconomiseurHP1.TwoPhaseFlowPipe.P[4],EconomiseurHP1.TwoPhaseFlowPipe.Q[1],EconomiseurHP1.TwoPhaseFlowPipe.Q[2],EconomiseurHP1.TwoPhaseFlowPipe.Q[3],EconomiseurHP1.TwoPhaseFlowPipe.Q[4],EconomiseurHP1.TwoPhaseFlowPipe.h[2],EconomiseurHP1.TwoPhaseFlowPipe.h[3],EconomiseurHP1.TwoPhaseFlowPipe.h[4],SurchauffeurHP2.ExchangerWall.Tp[1],SurchauffeurHP2.ExchangerWall.Tp[2],SurchauffeurHP2.ExchangerWall.Tp[3],SurchauffeurHP2.TwoPhaseFlowPipe.P[2],SurchauffeurHP2.TwoPhaseFlowPipe.P[3],SurchauffeurHP2.TwoPhaseFlowPipe.P[4],SurchauffeurHP2.TwoPhaseFlowPipe.Q[1],SurchauffeurHP2.TwoPhaseFlowPipe.Q[2],SurchauffeurHP2.TwoPhaseFlowPipe.Q[3],SurchauffeurHP2.TwoPhaseFlowPipe.h[2],SurchauffeurHP2.TwoPhaseFlowPipe.h[3],SurchauffeurHP2.TwoPhaseFlowPipe.h[4],SurchauffeurHP3.ExchangerWall.Tp[1],SurchauffeurHP3.ExchangerWall.Tp[2],SurchauffeurHP3.ExchangerWall.Tp[3],SurchauffeurHP3.TwoPhaseFlowPipe.P[2],SurchauffeurHP3.TwoPhaseFlowPipe.P[3],SurchauffeurHP3.TwoPhaseFlowPipe.P[4],SurchauffeurHP3.TwoPhaseFlowPipe.Q[1],SurchauffeurHP3.TwoPhaseFlowPipe.Q[2],SurchauffeurHP3.TwoPhaseFlowPipe.Q[3],SurchauffeurHP3.TwoPhaseFlowPipe.Q[4],SurchauffeurHP3.TwoPhaseFlowPipe.h[2],SurchauffeurHP3.TwoPhaseFlowPipe.h[3],SurchauffeurHP3.TwoPhaseFlowPipe.h[4],BallonMP.P,BallonMP.hl,BallonMP.hv,BallonMP.Tp,BallonMP.Vv,EvaporateurMP.ExchangerWall.Tp[1],EvaporateurMP.ExchangerWall.Tp[2],EvaporateurMP.ExchangerWall.Tp[3],EvaporateurMP.TwoPhaseFlowPipe.P[2],EvaporateurMP.TwoPhaseFlowPipe.P[3],EvaporateurMP.TwoPhaseFlowPipe.P[4],EvaporateurMP.TwoPhaseFlowPipe.Q[1],EvaporateurMP.TwoPhaseFlowPipe.Q[2],EvaporateurMP.TwoPhaseFlowPipe.Q[3],EvaporateurMP.TwoPhaseFlowPipe.Q[4],EvaporateurMP.TwoPhaseFlowPipe.h[2],EvaporateurMP.TwoPhaseFlowPipe.h[3],EvaporateurMP.TwoPhaseFlowPipe.h[4],VolumeEvapMP.h,EconomiseurMP.ExchangerWall.Tp[1],EconomiseurMP.ExchangerWall.Tp[2],EconomiseurMP.ExchangerWall.Tp[3],EconomiseurMP.TwoPhaseFlowPipe.P[2],EconomiseurMP.TwoPhaseFlowPipe.P[3],EconomiseurMP.TwoPhaseFlowPipe.P[4],EconomiseurMP.TwoPhaseFlowPipe.Q[1],EconomiseurMP.TwoPhaseFlowPipe.Q[2],EconomiseurMP.TwoPhaseFlowPipe.Q[3],EconomiseurMP.TwoPhaseFlowPipe.Q[4],EconomiseurMP.TwoPhaseFlowPipe.h[2],EconomiseurMP.TwoPhaseFlowPipe.h[3],EconomiseurMP.TwoPhaseFlowPipe.h[4],SurchauffeurMP1.ExchangerWall.Tp[1],SurchauffeurMP1.ExchangerWall.Tp[2],SurchauffeurMP1.ExchangerWall.Tp[3],SurchauffeurMP1.TwoPhaseFlowPipe.P[2],SurchauffeurMP1.TwoPhaseFlowPipe.P[3],SurchauffeurMP1.TwoPhaseFlowPipe.P[4],SurchauffeurMP1.TwoPhaseFlowPipe.Q[1],SurchauffeurMP1.TwoPhaseFlowPipe.Q[2],SurchauffeurMP1.TwoPhaseFlowPipe.Q[3],SurchauffeurMP1.TwoPhaseFlowPipe.Q[4],SurchauffeurMP1.TwoPhaseFlowPipe.h[2],SurchauffeurMP1.TwoPhaseFlowPipe.h[3],SurchauffeurMP1.TwoPhaseFlowPipe.h[4],MelangeurHPMP.h,SurchauffeurMP2.ExchangerWall.Tp[1],SurchauffeurMP2.ExchangerWall.Tp[2],SurchauffeurMP2.ExchangerWall.Tp[3],SurchauffeurMP2.TwoPhaseFlowPipe.P[2],SurchauffeurMP2.TwoPhaseFlowPipe.P[3],SurchauffeurMP2.TwoPhaseFlowPipe.P[4],SurchauffeurMP2.TwoPhaseFlowPipe.Q[1],SurchauffeurMP2.TwoPhaseFlowPipe.Q[2],SurchauffeurMP2.TwoPhaseFlowPipe.Q[3],SurchauffeurMP2.TwoPhaseFlowPipe.h[2],SurchauffeurMP2.TwoPhaseFlowPipe.h[3],SurchauffeurMP2.TwoPhaseFlowPipe.h[4],SurchauffeurMP3.ExchangerWall.Tp[1],SurchauffeurMP3.ExchangerWall.Tp[2],SurchauffeurMP3.ExchangerWall.Tp[3],SurchauffeurMP3.TwoPhaseFlowPipe.P[2],SurchauffeurMP3.TwoPhaseFlowPipe.P[3],SurchauffeurMP3.TwoPhaseFlowPipe.P[4],SurchauffeurMP3.TwoPhaseFlowPipe.Q[1],SurchauffeurMP3.TwoPhaseFlowPipe.Q[2],SurchauffeurMP3.TwoPhaseFlowPipe.Q[3],SurchauffeurMP3.TwoPhaseFlowPipe.Q[4],SurchauffeurMP3.TwoPhaseFlowPipe.h[2],SurchauffeurMP3.TwoPhaseFlowPipe.h[3],SurchauffeurMP3.TwoPhaseFlowPipe.h[4],BallonBP.P,BallonBP.hl,BallonBP.hv,BallonBP.Tp,BallonBP.Vv,VolumeEvapBP.h,EvaporateurBP.ExchangerWall.Tp[1],EvaporateurBP.ExchangerWall.Tp[2],EvaporateurBP.ExchangerWall.Tp[3],EvaporateurBP.TwoPhaseFlowPipe.P[2],EvaporateurBP.TwoPhaseFlowPipe.P[3],EvaporateurBP.TwoPhaseFlowPipe.P[4],EvaporateurBP.TwoPhaseFlowPipe.Q[1],EvaporateurBP.TwoPhaseFlowPipe.Q[2],EvaporateurBP.TwoPhaseFlowPipe.Q[3],EvaporateurBP.TwoPhaseFlowPipe.Q[4],EvaporateurBP.TwoPhaseFlowPipe.h[2],EvaporateurBP.TwoPhaseFlowPipe.h[3],EvaporateurBP.TwoPhaseFlowPipe.h[4],SurchauffeurBP.ExchangerWall.Tp[1],SurchauffeurBP.ExchangerWall.Tp[2],SurchauffeurBP.ExchangerWall.Tp[3],SurchauffeurBP.TwoPhaseFlowPipe.P[2],SurchauffeurBP.TwoPhaseFlowPipe.P[3],SurchauffeurBP.TwoPhaseFlowPipe.P[4],SurchauffeurBP.TwoPhaseFlowPipe.Q[1],SurchauffeurBP.TwoPhaseFlowPipe.Q[2],SurchauffeurBP.TwoPhaseFlowPipe.Q[3],SurchauffeurBP.TwoPhaseFlowPipe.Q[4],SurchauffeurBP.TwoPhaseFlowPipe.h[2],SurchauffeurBP.TwoPhaseFlowPipe.h[3],SurchauffeurBP.TwoPhaseFlowPipe.h[4],EconomiseurBP.ExchangerWall.Tp[1],EconomiseurBP.ExchangerWall.Tp[2],EconomiseurBP.ExchangerWall.Tp[3],EconomiseurBP.TwoPhaseFlowPipe.P[2],EconomiseurBP.TwoPhaseFlowPipe.P[3],EconomiseurBP.TwoPhaseFlowPipe.P[4],EconomiseurBP.TwoPhaseFlowPipe.Q[1],EconomiseurBP.TwoPhaseFlowPipe.Q[2],EconomiseurBP.TwoPhaseFlowPipe.Q[3],EconomiseurBP.TwoPhaseFlowPipe.Q[4],EconomiseurBP.TwoPhaseFlowPipe.h[2],EconomiseurBP.TwoPhaseFlowPipe.h[3],EconomiseurBP.TwoPhaseFlowPipe.h[4],MelangeurPostTMP1.h,Condenseur.P,Condenseur.hl,Condenseur.hv,Condenseur.Vv,VolumeCond1.h,VolumeAlimMPHP.h,regulation_Niveau_HP.pIsat.Integrateur1.x,regulation_Niveau_HP.pT1_1.x,regulation_Niveau_MP.pIsat.Integrateur1.x,regulation_Niveau_MP.pT1_1.x,regulation_Niveau_BP.pIsat.Integrateur1.x,regulation_Niveau_BP.pT1_1.x,regulation_Niveau_Condenseur.pIsat.Integrateur1.x,regulation_Niveau_Condenseur.pIsat1.Integrateur1.x,regulation_Niveau_Condenseur.pT1_1.x,regulation_Niveau_Condenseur.pT1_2.x,regulation_Niveau_Condenseur.pT1_3.x,VolumeECO_HP1_2.P,VolumeECO_HP1_2.h,VolumeECO_HP2_3.P,VolumeECO_HP2_3.h,VolumePreTHP.P,VolumePreTHP.h,MelangeurPreTMP.P,MelangeurPreTMP.h) * Number of discrete variables: 9 ($whenCondition1,regulation_Niveau_HP.pIsat.Integrateur1.x0,regulation_Niveau_MP.pIsat.Integrateur1.x0,regulation_Niveau_BP.pIsat.Integrateur1.x0,regulation_Niveau_Condenseur.pIsat.Integrateur1.x0,regulation_Niveau_Condenseur.pIsat1.Integrateur1.x0,regulation_Niveau_Condenseur.edge.uL.signal,regulation_Niveau_Condenseur.edge.yL.signal,regulation_Niveau_Condenseur.echelon.yL.signal) * Number of discrete states: 3 (regulation_Niveau_Condenseur.echelon.yL.signal,regulation_Niveau_Condenseur.edge.yL.signal,regulation_Niveau_Condenseur.edge.uL.signal) * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for simulation (4810): * Single equations (assignments): 4352 * Array equations: 0 * Algorithm blocks: 2 * Record equations: 276 * When equations: 5 * If-equations: 0 * Equation systems (not torn): 5 * Torn equation systems: 170 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 4 systems {(2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%)} * Non-linear Jacobian (size): 1 system {1} * Without analytic Jacobian (size): 0 systems Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 69 systems {(4,1,62.5%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (4,1,62.5%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (4,1,62.5%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (4,1,62.5%), (1,1,100.0%), (1,2,100.0%), (1,1,100.0%), (1,2,100.0%), (1,2,100.0%), (1,1,100.0%), (2,1,100.0%), (2,1,100.0%), (1,1,100.0%), (1,1,100.0%), (2,1,100.0%), (2,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (2,1,100.0%), (2,1,100.0%)} * Non-linear torn systems (#iteration vars, #inner vars): 101 systems {(1,6), (1,5), (1,1), (1,3), (1,6), (1,3), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,34), (1,6), (1,6), (1,6), (1,34), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,34), (1,6), (1,6), (1,6), (1,5), (1,1), (1,3), (1,6), (1,3), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,34), (1,6), (1,6), (1,6), (1,5), (1,1), (1,6), (1,3), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,2), (1,2), (1,5), (1,2), (1,2), (1,3), (1,5), (3,16), (1,5), (1,3), (6,14), (1,3), (6,14), (1,3), (1,3), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (1,4), (1,4), (1,4), (1,5), (1,3), (8,15), (1,3)} Notification: Performance of Backend phase and start with SimCode phase: time 0.03036/8.713, allocations: 5.092 MB / 3.039 GB, free: 231.8 MB / 0.9324 GB Notification: Performance of simCode: created initialization part: time 0.1378/8.85, allocations: 99.63 MB / 3.137 GB, free: 166.6 MB / 0.9324 GB Notification: Performance of simCode: created event and clocks part: time 0.0002256/8.851, allocations: 136.4 kB / 3.137 GB, free: 166.6 MB / 0.9324 GB Notification: Performance of simCode: created simulation system equations: time 0.07889/8.93, allocations: 43.97 MB / 3.18 GB, free: 148.5 MB / 0.9324 GB Notification: Performance of simCode: created of all other equations (e.g. parameter, nominal, assert, etc): time 0.07342/9.003, allocations: 16.73 MB / 3.196 GB, free: 146.5 MB / 0.9324 GB Notification: Performance of simCode: created linear, non-linear and system jacobian parts: time 0.1886/9.192, allocations: 95.28 MB / 3.289 GB, free: 71 MB / 0.9324 GB Notification: Performance of simCode: some other stuff during SimCode phase: time 0.01114/9.203, allocations: 10.8 MB / 3.3 GB, free: 62.91 MB / 0.9324 GB Notification: Performance of simCode: alias equations: time 0.02624/9.229, allocations: 4.721 MB / 3.304 GB, free: 58.59 MB / 0.9324 GB Notification: Performance of simCode: all other stuff during SimCode phase: time 0.03762/9.267, allocations: 11.02 MB / 3.315 GB, free: 47.49 MB / 0.9324 GB Notification: Performance of SimCode: time 2.495e-06/9.267, allocations: 2.062 kB / 3.315 GB, free: 47.49 MB / 0.9324 GB Notification: Performance of Templates: time 3.126/12.39, allocations: 1.448 GB / 4.763 GB, free: 197.8 MB / 0.9481 GB " [Timeout remaining time 648] make -j1 -f ThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC.makefile [Timeout 660] (rm -f ThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC.pipe ; mkfifo ThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC.pipe ; head -c 1048576 < ThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC.pipe >> ../files/ThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC.sim & ./ThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC -abortSlowSimulation -alarm=240 -s gbode -gbm=radauIIA3 -lv LOG_STATS > ThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC.pipe 2>&1) [Timeout 240] [Calling os._exit(0), Time elapsed: 67.29863261291757]